Discussion of “Case Studies of Leak Detection and Location in Water Pipe Systems by Inverse Transient Analysis” by Dídia Covas and Helena Ramos

2013 ◽  
Vol 139 (1) ◽  
pp. 126-127 ◽  
Author(s):  
Bruno Brunone ◽  
Silvia Meniconi
Author(s):  
Oussama Choura ◽  
Caterina Capponi ◽  
Silvia Meniconi ◽  
Sami Elaoud ◽  
Bruno Brunone

Abstract In this paper the results of an experimental validation of a technique for leak detection in polymeric pipes based on the inverse transient analysis (ITA) are presented. In the proposed ITA the Nelder–Mead algorithm is used as a calibration tool. Experimental tests have been carried out in an intact and leaky high-density polyethylene (HDPE) single pipe installed at the Water Engineering Laboratory (WEL) of the University of Perugia, Italy. Transients have been generated by the fast and complete closure of a valve placed at the downstream end section of the pipe. In the first phase of the calibration procedure, the proposed algorithm has been used to estimate both the viscoelastic parameters of a generalized Kelvin–Voigt model and the unsteady-state friction coefficient, by minimizing the difference between the numerical and experimental results. In the second phase of the procedure, the calibrated model allowed the evaluation of leak size and location with an acceptable accuracy. Precisely, in terms of leak location the relative error was smaller than 5%.


2021 ◽  
Author(s):  
Lawrence Camilleri ◽  
Mohammed Al-Jorani ◽  
Mohammed Kamal Aal Najar ◽  
Joseph Ayoub

Abstract While pressure transient analysis (PTA) is a proven interpretation technique, it is mostly used on buildups because drawdowns are difficult to interpret. However, the deferred production associated with buildups discourages regular application of PTA to determine skin and identify boundary conditions. Several case studies are presented covering a range of well configurations to illustrate how downhole transient liquid rate measurements with electrical submersible pump (ESP) gauges enable PTA during drawdown and therefore real-time optimization. The calculation of high-frequency transient flow rates using ESP gauge real-time data is based on the principle that the power absorbed by the pump is equal to that generated by the motor. This technique is independent of fluid specific gravity and therefore is self-calibrating with changes in water cut and phase segregation. Analytical equations ensure that the physics is always respected, thereby providing the necessary repeatability. The combination of downhole transient high-frequency flow rate and permanent pressure gauge data enables PTA using commonly available analytical techniques and software, especially because superposition time is calculated accurately. The availability of continuous production history brings significant value for PTA. It makes it possible to perform history matching and to deploy semilog analysis using an accurate set of superposition time functions. However, the application of log-log analysis techniques is usually more challenging because of imperfections in input data such as noise, oversimplified production history, time-synchronization issues, or wellbore effects. These limitations are solved by utilizing high-frequency downhole data from ESP. This is possible first as superposition time is effectively an integral function, which dampens any noise in the flow rate signal. Another important finding is that wellbore effects in subhydrostatic wells are less impactful in drawdowns than in buildups where compressibility and redistribution can mask reservoir response. Key reservoir properties, in particular mobility, can nearly always be estimated, leading to better skin factor determination even without downhole shut-in. Finally, with the constraint of production deferment eliminated, drawdowns can be monitored for extended durations to identify boundaries and to perform time-lapse interpretation more efficiently. Confirming a constant pressure boundary or a change in skin enables more effective and proactive production management. In all cases considered, a complete analysis was possible, including buildup and drawdown data comparison. With the development of downhole flow rate calculation technology, it is now possible to provide full inflow characterization in a matter of days following an ESP workover, without any additional hardware or staff mobilization to the wellsite and no deferred production. More importantly, the technique provides the necessary information to diagnose the cause of underproduction, identify stimulation candidates, and manage drawdown.


Sensors ◽  
2014 ◽  
Vol 14 (3) ◽  
pp. 5595-5610 ◽  
Author(s):  
Fabrício Almeida ◽  
Michael Brennan ◽  
Phillip Joseph ◽  
Stuart Whitfield ◽  
Simon Dray ◽  
...  

Author(s):  
Marcos Guillen ◽  
Jean F. Dulhoste ◽  
Gildas Besancon ◽  
Ignacio Rubio S. ◽  
Rafael Santos ◽  
...  

2020 ◽  
Vol 11 (3) ◽  
pp. 04020024
Author(s):  
Shaofeng Wang ◽  
Zhihao Chen ◽  
Jianguo Wang ◽  
Hailing Wang ◽  
Chunsheng Ji ◽  
...  

2020 ◽  
Author(s):  
Matthew Barrett ◽  
Zohreh Andalibi ◽  
Tatiana Baeva ◽  
Adam Chan

Sign in / Sign up

Export Citation Format

Share Document