Bearing Capacity Evaluation of Ultra Thin Reinforced Concrete Pavement Sections through Accelerated Pavement Testing and Modeling in South Africa

Author(s):  
L. du Plessis ◽  
P. J. Strauss ◽  
A. Kilian
2017 ◽  
Vol 9 (5) ◽  
pp. 507-519
Author(s):  
Justas Šlaitas

The research was made on condition assessment of flexed reinforced concrete structures, strengthened with fibre reinforced polymers, in fracture stage. Universal bearing capacity calculation method based on limit normal section crack depth was proposed. This paper confirms the hypothesis of triangular concrete’s compressive zone chart usage for flexural strength calculation, without tensile concrete above crack evaluation. There is established connection between crack depth and FRP stress­strain, which allows to decide about structures bearing capacity reserve. The calculation results are confirmed with experimental studies of 73 reinforced concrete beams, strengthened with carbon fibre reinforced polymer (CFRP) and glass fibre reinforced polymer (GFRP) sheets, plates, strips and rods, taken from different researches. Furthermore, recommended limits of strengthening with FRP were proposed.


Author(s):  
Л. Р. Маилян ◽  
С. А. Стельмах ◽  
Е. М. Щербань ◽  
М. П. Нажуев

Состояние проблемы. Железобетонные элементы изготавливаются, как правило, по трем основным технологиям - вибрированием, центрифугированием и виброцентрифугированием. Однако все основные расчетные зависимости для определения их несущей способности выведены, исходя из основного постулата - постоянства и равенства характеристик бетона по сечению, что реализуется лишь в вибрированных колоннах. Результаты. В рамках диаграммного подхода предложены итерационный, приближенный и упрощенный способы расчета несущей способности железобетонных вибрированных, центрифугированных и виброцентрифугированных колонн. Выводы. Расчет по диаграммному подходу показал существенно более подходящую сходимость с опытными данными, чем расчет по методике норм, а также дал лучшие результаты при использовании дифференциальных характеристик бетона, чем при использовании интегральных и, тем более, нормативных характеристик бетона. Statement of the problem. Reinforced concrete elements are typically manufactured according to three basic technologies - vibration, centrifugation and vibrocentrifugation. However, all the basic calculated dependencies for determining their bearing capacity were derived using the main postulate, i.e., the constancy and equality of the characteristics of concrete over the cross section, which is implemented only in vibrated columns. Results. Within the framework of the diagrammatic approach, iterative, approximate and simplified methods of calculating the bearing capacity of reinforced concrete vibrated, centrifuged and vibrocentrifuged columns are proposed. Conclusions. The calculation according to the diagrammatic approach showed a significantly better convergence with the experimental data than that using the method of norms, and also performs better when using differential characteristics of concrete than when employing integral and particularly standard characteristics of concrete.


Sign in / Sign up

Export Citation Format

Share Document