Coherent structures in electrokinetic instability with orthogonal conductivity gradient and electric field

2017 ◽  
Vol 29 (9) ◽  
pp. 092007 ◽  
Author(s):  
Kaushlendra Dubey ◽  
Amit Gupta ◽  
Supreet Singh Bahga
2021 ◽  
Vol 925 ◽  
Author(s):  
Kaushlendra Dubey ◽  
Sanjeev Sanghi ◽  
Amit Gupta ◽  
Supreet Singh Bahga

We present an experimental and numerical investigation of electrokinetic instability (EKI) in microchannel flow with streamwise conductivity gradients, such as those observed during sample stacking in capillary electrophoresis. A plug of a low-conductivity electrolyte solution is initially sandwiched between two high-conductivity zones in a microchannel. This spatial conductivity gradient is subjected to an external electric field applied along the microchannel axis, and for sufficiently strong electric fields an instability sets in. We have explored the physics of this EKI through experiments and numerical simulations, and supplemented the results using scaling analysis. We performed EKI experiments at different electric field values and visualised the flow using a passive fluorescent tracer. The experimental data were analysed using the proper orthogonal decomposition technique to obtain a quantitative measure of the threshold electric field for the onset of instability, along with the corresponding coherent structures. To elucidate the physical mechanism underlying the instability, we performed high-resolution numerical simulations of ion transport coupled with fluid flow driven by the electric body force. Simulations reveal that the non-uniform electroosmotic flow due to axially varying conductivity field causes a recirculating flow within the low-conductivity region, and creates a new configuration wherein the local conductivity gradients are orthogonal to the applied electric field. This configuration leads to EKI above a threshold electric field. The spatial features of the instability predicted by the simulations and the threshold electric field are in good agreement with the experimental observations and provide useful insight into the underlying mechanism of instability.


Author(s):  
Zheyan Jin ◽  
Hui Hu

An experimental study was conducted to further our understanding about the fundamental physics of electrokinetic instability (EKI) and to explore the effectiveness to enhance fluid mixing inside a Y-shaped microchannel by manipulating convective EKI waves. The dependence of the critical voltage of applied static electric field to trig EKI to generate convective EKI waves on the conductivity ratio of the two adjacent streams was quantified at first. The effect of the strength of the applied static electric field on the evolution of the convective EKI waves and fluid mixing process were assessed in terms of scalar concentration fields, shedding frequency of the convective EKI waves and scalar mixing efficiency. The effectiveness of manipulating the convective EKI waves by introducing alternative electric perturbations to the applied static electric fields was also explored for the further enhancement of the fluid mixing process inside the Y-shaped microchannel.


2009 ◽  
Vol 60-61 ◽  
pp. 330-333
Author(s):  
Wei Chih Chen ◽  
Ting Fu Hong ◽  
Wen Bo Luo ◽  
Chang Hsien Tai ◽  
Chien Hsiung Tsai ◽  
...  

This paper presented a parametric experimental study of electrokinetic instability phenomena in a cross-shaped configuration microfluidic device with varying channel depths and conductivity ratios. The flow instability is observed when applied electric field strength exceeds a certain critical value. The critical electric field strength is examined as a function of the conductivity ratio of two samples liquid, microchannel depth, and the treatment of microchannel wetted surface. It is found that the critical electric field strengths for the onset of electrokinetic instability are strongly dependent on the conductivity ratio of two samples liquid, and decrease as the channel depths increasing of microfluidic devices. In the present study, the surface inside microchannels is treated utilizing hydrophilic and hydrophobic organic-based SOG (spin-on-glass) nanofilms for glass-based microchips. The experimental results indicate that no significant difference for the critical electric fields for the onset of electrokinetic instability phenomena in both hydrophilic and hydrophobic SOG coating in the surface of microchannels. The critical electric fields for the onset of electrokinetic instability phenomena are slightly lower in both SOG coated cases in compare with that of the non-coated microchannel.


Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 3018 ◽  
Author(s):  
Christoph Jörgens ◽  
Markus Clemens

Many processes are involved in the accumulation of space charges within the insulation materials of high voltage direct current (HVDC) cables, e.g., the local electric field, a conductivity gradient inside the insulation, and the injection of charges at both electrodes. An accurate description of the time dependent charge distribution needs to include these effects. Furthermore, using an explicit Euler method for the time integration of a suitably formulated transient model, low time steps are used to resolve fast charge dynamics and to satisfy the Courant–Friedrichs–Lewy (CFL) stability condition. The long lifetime of power cables makes the use of a final stationary charge distribution necessary to assess the reliability of the cable insulations. For an accurate description of the stationary space charge and electric field distribution, an empirical conductivity equation is developed. The bulk conductivity, found in literature, is extended with two sigmoid functions to represent a conductivity gradient near the electrodes. With this extended conductivity equation, accumulated bulk space charges and hetero charges are simulated. New introduced constants to specify the sigmoid functions are determined by space charge measurements, taken from the literature. The measurements indicate accumulated hetero charges in about one quarter of the insulation thickness in the vicinity of both electrodes. The simulation results conform well to published measurements and show an improvement to previously published models, i.e., the developed model shows a good approximation to simulate the stationary bulk and hetero charge distribution.


Micromachines ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 34
Author(s):  
Fang Yang ◽  
Wei Zhao ◽  
Cuifang Kuang ◽  
Guiren Wang

We report a quasi T-channel electrokinetics-based micromixer with electrically conductive sidewalls, where the electric field is in the transverse direction of the flow and parallel to the conductivity gradient at the interface between two fluids to be mixed. Mixing results are first compared with another widely studied micromixer configuration, where electrodes are located at the inlet and outlet of the channel with electric field parallel to bulk flow direction but orthogonal to the conductivity gradient at the interface between the two fluids to be mixed. Faster mixing is achieved in the micromixer with conductive sidewalls. Effects of Re numbers, applied AC voltage and frequency, and conductivity ratio of the two fluids to be mixed on mixing results were investigated. The results reveal that the mixing length becomes shorter with low Re number and mixing with increased voltage and decreased frequency. Higher conductivity ratio leads to stronger mixing result. It was also found that, under low conductivity ratio, compared with the case where electrodes are located at the end of the channel, the conductive sidewalls can generate fast mixing at much lower voltage, higher frequency, and lower conductivity ratio. The study of this micromixer could broaden our understanding of electrokinetic phenomena and provide new tools for sample preparation in applications such as organ-on-a-chip where fast mixing is required.


Author(s):  
Kaushlendra Dubey ◽  
Amit Gupta ◽  
Supreet Singh Bahga

In this work, we performed an experimental study of electrohydrodynamic effects on the dispersion of sample ions in field amplified sample stacking (FASS). A typical FASS experiment involves a streamwise electrical conductivity gradient collinear to the applied electric field to enhance the sample stacking. Earlier studies on FASS have focused on how the conductivity gradient sets a non-uniform electro-osmotic flow which causes the dispersion. However, the coupling of the electric field with conductivity gradient leads to a destabilizing electric body force and generates unstable flow. This work demonstrates that generated body force influences the dynamics of FASS. We present a scaling analysis to show that at high fields, electrohydrodynamic effects play a vital role in sample dispersion. To justify our scaling arguments, we performed experiments at varied electric fields which shows that at high electric fields maximum concentration enhancement is lowered significantly. To ensure the EHD effects on the dynamics of FASS, we have also performed experiments with suppressed EOF conditions.


Sign in / Sign up

Export Citation Format

Share Document