scholarly journals Homeostatic enhancement of sensory transduction

2017 ◽  
Vol 114 (33) ◽  
pp. E6794-E6803 ◽  
Author(s):  
Andrew R. Milewski ◽  
Dáibhid Ó Maoiléidigh ◽  
Joshua D. Salvi ◽  
A. J. Hudspeth

Our sense of hearing boasts exquisite sensitivity, precise frequency discrimination, and a broad dynamic range. Experiments and modeling imply, however, that the auditory system achieves this performance for only a narrow range of parameter values. Small changes in these values could compromise hair cells’ ability to detect stimuli. We propose that, rather than exerting tight control over parameters, the auditory system uses a homeostatic mechanism that increases the robustness of its operation to variation in parameter values. To slowly adjust the response to sinusoidal stimulation, the homeostatic mechanism feeds back a rectified version of the hair bundle’s displacement to its adaptation process. When homeostasis is enforced, the range of parameter values for which the sensitivity, tuning sharpness, and dynamic range exceed specified thresholds can increase by more than an order of magnitude. Signatures in the hair cell’s behavior provide a means to determine through experiment whether such a mechanism operates in the auditory system. Robustness of function through homeostasis may be ensured in any system through mechanisms similar to those that we describe here.

F1000Research ◽  
2018 ◽  
Vol 7 ◽  
pp. 200 ◽  
Author(s):  
Steven A. Frank

Sensory perception often scales logarithmically with the input level. Similarly, the output response of biochemical systems sometimes scales logarithmically with the input signal that drives the system. How biochemical systems achieve logarithmic sensing remains an open puzzle. This article shows how a biochemical logarithmic sensor can be constructed from the most basic principles of chemical reactions. Assuming that reactions follow the classic Michaelis-Menten kinetics of mass action or the more generalized and commonly observed Hill equation response, the summed output of several simple reactions with different sensitivities to the input will often give an aggregate output response that logarithmically transforms the input. The logarithmic response is robust to stochastic fluctuations in parameter values. This model emphasizes the simplicity and robustness by which aggregate chemical circuits composed of sloppy components can achieve precise response characteristics. Both natural and synthetic designs gain from the power of this aggregate approach.


F1000Research ◽  
2018 ◽  
Vol 7 ◽  
pp. 200 ◽  
Author(s):  
Steven A. Frank

Sensory perception often scales logarithmically with the input level. Similarly, the output response of biochemical systems sometimes scales logarithmically with the input signal that drives the system. How biochemical systems achieve logarithmic sensing remains an open puzzle. This article shows how a biochemical logarithmic sensor can be constructed from the most basic principles of chemical reactions. Assuming that reactions follow the classic Michaelis-Menten kinetics of mass action or the more generalized and commonly observed Hill equation response, the summed output of several simple reactions with different sensitivities to the input will often give an aggregate output response that logarithmically transforms the input. The logarithmic response is robust to stochastic fluctuations in parameter values. This model emphasizes the simplicity and robustness by which aggregate chemical circuits composed of sloppy components can achieve precise response characteristics. Both natural and synthetic designs gain from the power of this aggregate approach.


F1000Research ◽  
2018 ◽  
Vol 7 ◽  
pp. 200 ◽  
Author(s):  
Steven A. Frank

Sensory perception often scales logarithmically with the input level. Similarly, the output response of biochemical systems sometimes scales logarithmically with the input signal that drives the system. How biochemical systems achieve logarithmic sensing remains an open puzzle. This article shows how a biochemical logarithmic sensor can be constructed from the most basic principles of chemical reactions. Assuming that reactions follow the classic Michaelis-Menton kinetics of mass action or the more generalized and commonly observed Hill equation response, the summed output of several simple reactions with different sensitivities to the input will often give an aggregate output response that logarithmically transforms the input. The logarithmic response is robust to stochastic fluctuations in parameter values. This model emphasizes the simplicity and robustness by which aggregate chemical circuits composed of sloppy components can achieve precise response characteristics. Both natural and synthetic designs gain from the power of this aggregate approach.


1986 ◽  
Vol 29 (3) ◽  
pp. 420-424 ◽  
Author(s):  
Michael Dorman ◽  
Ingrid Cedar ◽  
Maureen Hannley ◽  
Marjorie Leek ◽  
Julie Mapes Lindholm

Computer synthesized vowels of 50- and 300-ms duration were presented to normal-hearing listeners at a moderate and high sound pressure level (SPL). Presentation at the high SPL resulted in poor recognition accuracy for vowels of a duration (50 ms) shorter than the latency of the acoustic stapedial reflex. Presentation level had no effect on recognition accuracy for vowels of sufficient duration (300 ms) to elicit the reflex. The poor recognition accuracy for the brief, high intensity vowels was significantly improved when the reflex was preactivated. These results demonstrate the importance of the acoustic reflex in extending the dynamic range of the auditory system for speech recognition.


2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S92-S92
Author(s):  
M S Shapiro ◽  
X Wang ◽  
D R Mendu ◽  
A Firpo

Abstract Introduction/Objective Mount Sinai Hospital has received emergency use authorization (EUA) from the FDA for Coronavirus Disease 2019 (COVID-19) antibody testing using ELISA. This serological assay detects and titrates the presence of circulating antibodies to COVID-19. Other platforms have aimed to achieve the credentials of the ELISA instrument, including the multiplex assays of Luminex. The platform is known to have a greater throughput (384 wells vs. 96 wells per microplate) and faster processing speed (8 hours vs. 17 hours). Methods Luminex utilizes beads that couple to the same COVID-19 antigens (mRBD and mSpike) which were utilized for the ELISA assay. The beads are read determining the mean fluorescence intensity (MFI). In order to compare the two methods, our study included 61 patients with COVID-19 at Mount Sinai Hospital, to screen and titrate their sera using Luminex, and to correspond the MFI values with the ELISA titers. Results The Luminex assay has achieved the same level of confidence as ELISA. The 61 patients, representing 30 negatives and 31 positives, are consistently identified as such on both platforms. Our data highlights 32% of patients with a low titer (<1:160), 42% of patients with a high titer (1:160 ~ 1:320), and 26% of patients with a very high titer level (>1:320). These titers correlated well with the MFI values. Based on a cutoff of 80,000 MFI, the sensitivity and specificity of the assay is 98% and 85%, respectively, with no overlapping of MFI between positive and negative results. Conclusion Overall, the study has demonstrated that the Luminex is a strong alternative for the ELISA platform. The Luminex highlights the broad dynamic range with no overlapping between positives and negatives. Migration from ELISA to Luminex, a platform with faster and greater throughput, is therefore, highly desirable.


Author(s):  
Fanda Meng ◽  
Weisong Huo ◽  
Jie Lian ◽  
Lei Zhang ◽  
Xizeng Shi ◽  
...  

AbstractWe report a microfluidic sandwich immunoassay constructed around a dual-giant magnetoresistance (GMR) sensor array to quantify the heart failure biomarker NT-proBNP in human plasma at the clinically relevant concentration levels between 15 pg/mL and 40 ng/mL. The broad dynamic range was achieved by differential coating of two identical GMR sensors operated in tandem, and combining two standard curves. The detection limit was determined as 5 pg/mL. The assay, involving 53 plasma samples from patients with different cardiovascular diseases, was validated against the Roche Cobas e411 analyzer. The salient features of this system are its wide concentration range, low detection limit, small sample volume requirement (50 μL), and the need for a short measurement time of 15 min, making it a prospective candidate for practical use in point of care analysis.


2017 ◽  
Vol 83 (9) ◽  
Author(s):  
Adam Jordan ◽  
Jenna Chandler ◽  
Joshua S. MacCready ◽  
Jingcheng Huang ◽  
Katherine W. Osteryoung ◽  
...  

ABSTRACT Cyanobacteria are emerging as alternative crop species for the production of fuels, chemicals, and biomass. Yet, the success of these microbes depends on the development of cost-effective technologies that permit scaled cultivation and cell harvesting. Here, we investigate the feasibility of engineering cell morphology to improve biomass recovery and decrease energetic costs associated with lysing cyanobacterial cells. Specifically, we modify the levels of Min system proteins in Synechococcus elongatus PCC 7942. The Min system has established functions in controlling cell division by regulating the assembly of FtsZ, a tubulin-like protein required for defining the bacterial division plane. We show that altering the expression of two FtsZ-regulatory proteins, MinC and Cdv3, enables control over cell morphology by disrupting FtsZ localization and cell division without preventing continued cell growth. By varying the expression of these proteins, we can tune the lengths of cyanobacterial cells across a broad dynamic range, anywhere from an ∼20% increased length (relative to the wild type) to near-millimeter lengths. Highly elongated cells exhibit increased rates of sedimentation under low centrifugal forces or by gravity-assisted settling. Furthermore, hyperelongated cells are also more susceptible to lysis through the application of mild physical stress. Collectively, these results demonstrate a novel approach toward decreasing harvesting and processing costs associated with mass cyanobacterial cultivation by altering morphology at the cellular level. IMPORTANCE We show that the cell length of a model cyanobacterial species can be programmed by rationally manipulating the expression of protein factors that suppress cell division. In some instances, we can increase the size of these cells to near-millimeter lengths with this approach. The resulting elongated cells have favorable properties with regard to cell harvesting and lysis. Furthermore, cells treated in this manner continue to grow rapidly at time scales similar to those of uninduced controls. To our knowledge, this is the first reported example of engineering the cell morphology of cyanobacteria or algae to make them more compatible with downstream processing steps that present economic barriers to their use as alternative crop species. Therefore, our results are a promising proof-of-principle for the use of morphology engineering to increase the cost-effectiveness of the mass cultivation of cyanobacteria for various sustainability initiatives.


2011 ◽  
Vol 2 (1) ◽  
Author(s):  
Scott M. Tabakman ◽  
Lana Lau ◽  
Joshua T. Robinson ◽  
Jordan Price ◽  
Sarah P. Sherlock ◽  
...  

2015 ◽  
Vol 51 (28) ◽  
pp. 6145-6148 ◽  
Author(s):  
Robert J. Meier ◽  
Johann M. B. Simbürger ◽  
Tero Soukka ◽  
Michael Schäferling

A FRET system composed of a europium chelate and carboxynaphthofluorescein enables ratiometric pH sensing with an exceptionally broad dynamic range.


2013 ◽  
Vol 20 (1) ◽  
pp. 19-23 ◽  
Author(s):  
V. M. Vasyliūnas

Abstract. The depression of the horizontal magnetic field at Earth's equator for the largest imaginable magnetic storm has been estimated (Vasyliūnas, 2011a) as −Dst ~ 2500 nT, from the assumption that the total pressure in the magnetosphere (plasma plus magnetic field perturbation) is limited, in order of magnitude, by the minimum pressure of Earth's dipole field at the location of each flux tube. The obvious related question is how long it would take the solar wind to supply the energy content of this largest storm. The maximum rate of energy input from the solar wind to the magnetosphere can be evaluated on the basis either of magnetotail stress balance or of polar cap potential saturation, giving an estimate of the time required to build up the largest storm, which (for solar-wind and magnetospheric parameter values typical of observed superstorms) is roughly between ~2 and ~6 h.


Sign in / Sign up

Export Citation Format

Share Document