LONG TERM DEFLECTIONS OF A REINFORCED CONCRETE FLAT PLATE

1972 ◽  
Vol 15 (2) ◽  
pp. 25-29
Author(s):  
J. L. HEIMAN ◽  
P. J. TAYLOR

Problems when calculating reinforced concrete structures based on the concrete deformation under compression diagram, which is presented both in Russian and foreign regulatory documents on the design of concrete and reinforced concrete structures are considered. The correctness of their compliance for all classes of concrete remains very approximate, especially a significant difference occurs when using Euronorm due to the different shape and sizes of the samples. At present, there are no methodical recommendations for determining the ultimate relative deformations of concrete under axial compression and the construction of curvilinear deformation diagrams, which leads to limited experimental data and, as a result, does not make it possible to enter more detailed ultimate strain values into domestic standards. The results of experimental studies to determine the ultimate relative deformations of concrete under compression for different classes of concrete, which allowed to make analytical dependences for the evaluation of the ultimate relative deformations and description of curvilinear deformation diagrams, are presented. The article discusses various options for using the deformation model to assess the stress-strain state of the structure, it is concluded that it is necessary to use not only the finite values of the ultimate deformations, but also their intermediate values. This requires reliable diagrams "s–e” for all classes of concrete. The difficulties of measuring deformations in concrete subjected to peak load, corresponding to the prismatic strength, as well as main cracks that appeared under conditions of long-term step loading are highlighted. Variants of more accurate measurements are proposed. Development and implementation of the new standard GOST "Concretes. Methods for determination of complete diagrams" on the basis of the developed method for obtaining complete diagrams of concrete deformation under compression for the evaluation of ultimate deformability of concrete under compression are necessary.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 254
Author(s):  
Alinda Dey ◽  
Akshay Vijay Vastrad ◽  
Mattia Francesco Bado ◽  
Aleksandr Sokolov ◽  
Gintaris Kaklauskas

The contribution of concrete to the tensile stiffness (tension stiffening) of a reinforced concrete (RC) member is a key governing factor for structural serviceability analyses. However, among the current tension stiffening models, few consider the effect brought forth by concrete shrinkage, and none studies take account of the effect for very long-term shrinkage. The present work intends to tackle this exact issue by testing multiple RC tensile elements (with different bar diameters and reinforcement ratios) after a five-year shrinking time period. The experimental deformative and tension stiffening responses were subjected to a mathematical process of shrinkage removal aimed at assessing its effect on the former. The results showed shrinkage distinctly lowered the cracking load of the RC members and caused an apparent tension stiffening reduction. Furthermore, both of these effects were exacerbated in the members with higher reinforcement ratios. The experimental and shrinkage-free behaviors of the RC elements were finally compared to the values predicted by the CEB-fib Model Code 2010 and the Euro Code 2. Interestingly, as a consequence of the long-term shrinkage, the codes expressed a smaller relative error when compared to the shrinkage-free curves versus the experimental ones.


1985 ◽  
Vol 50 ◽  
Author(s):  
A. Atkinson ◽  
D. J. Goult ◽  
J. A. Hearne

AbstractA preliminary assessment of the long-term durability of concrete in a repository sited in clay is presented. The assessment is based on recorded experience of concrete structures and both field and laboratory studies. It is also supported by results of the examination of a concrete sample which had been buried in clay for 43 years.The enoineering lifetime of a 1 m thick reinforced concrete slab, with one face in contact with clay, and the way in which pH in the repository as a whole is likely to vary with time have both been estimated from available data. The estimates indicate that engineering lifetimes of about 103 years are expected (providing that sulphate resisting cement is used) and that pH is likely to remain above 10.5 for about 106 years.


2016 ◽  
Vol 691 ◽  
pp. 51-60 ◽  
Author(s):  
Martin Krizma ◽  
Lubomir Bolha

The issue of strengthening the damaged linear reinforced concrete elements have been engaged since 2008. We focused on the analysis of resistance and the characteristics of limit states of serviceability in the damaged and subsequently strengthened elements at a short-term loading. In the introduction phase, the strengthening of the elements was carried out with the following procedures – installation of an overlayer on the coupling board or a combination of the board and use of glass – fiber fabric (GFRP). The strengthening was also affected by the type of contact (reinforced/non-reinforced) – the deformed element/coupling board and its effect on resistance, type of deformation and serviceability. In the non-reinforced contact, we applied some of the types of adjustments to the surface of the strengthened element. At the moment, we are dealing with the effects of time and repeated load on the strengthened elements. The results correspond to the reinforced contact. The values are compared with the short-term results of the strengthened beams and with the long-term results of the beams prepared for strengthening.


2019 ◽  
Vol 196 ◽  
pp. 649-658 ◽  
Author(s):  
D.H. Monetti ◽  
A. Llano-Torre ◽  
M.C. Torrijos ◽  
G. Giaccio ◽  
R. Zerbino ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document