Ionic conductivity along transmembrane-electropores in human aquaporin 4: calcium effects from non-equilibrium molecular dynamics

2019 ◽  
Vol 117 (23-24) ◽  
pp. 3783-3790 ◽  
Author(s):  
Mario Bernardi ◽  
Mohammad Reza Ghaani ◽  
Niall J. English
2019 ◽  
Vol 21 (6) ◽  
pp. 3339-3346 ◽  
Author(s):  
Mario Bernardi ◽  
Paolo Marracino ◽  
Micaela Liberti ◽  
José-Antonio Gárate ◽  
Christian J. Burnham ◽  
...  

Electroporation is a matter of intensive ongoing research interest, and a much-neglected topic in trans-membrane proteins, particularly in view of such promising potential applications in medicine and biotechnology.


2016 ◽  
Vol 296 ◽  
pp. 47-53 ◽  
Author(s):  
Johan Klarbring ◽  
Olga Yu. Vekilova ◽  
Johan O. Nilsson ◽  
Natalia V. Skorodumova ◽  
Sergei I. Simak

2018 ◽  
Vol 149 (24) ◽  
pp. 245102 ◽  
Author(s):  
Mario Bernardi ◽  
Paolo Marracino ◽  
Mohammad Reza Ghaani ◽  
Micaela Liberti ◽  
Federico Del Signore ◽  
...  

2020 ◽  
Vol 45 (4) ◽  
pp. 319-332
Author(s):  
Xiaoyu Chen ◽  
Ruquan Liang ◽  
Yong Wang ◽  
Ziqi Xia ◽  
Lichun Wu ◽  
...  

AbstractThe effect of the temperature gradient on the Soret coefficient in n-pentane/n-decane (n-C5/n-C10) mixtures was investigated using non-equilibrium molecular dynamics (NEMD) with the heat exchange (eHEX) algorithm. n-Pentane/n-decane mixtures with three different compositions (0.25, 0.5, and 0.75 mole fractions, respectively) and the TraPPE-UA force field were used in computing the Soret coefficient ({S_{T}}) at 300 K and 1 atm. Added/removed heat quantities (ΔQ) of 0.002, 0.004, 0.006, 0.008, and 0.01 kcal/mol were employed in eHEX processes in order to study the effect of different thermal gradients on the Soret coefficient. Moreover, a phenomenological description was applied to discuss the mechanism of this effect. Present results show that the Soret coefficient values firstly fluctuate violently and then become increasingly stable with increasing ΔQ (especially in the mixture with a mole fraction of 0.75), which means that ΔQ has a smaller effect on the Soret coefficient when the temperature gradient is higher than a certain thermal gradient. Thus, a high temperature gradient is recommended for calculating the Soret coefficient under the conditions that a linear response and constant phase are ensured in the system. In addition, the simulated Soret coefficient obtained at the highest ΔQ within three different compositions is in great agreement with experimental data.


Sign in / Sign up

Export Citation Format

Share Document