The assessment of fractal dimensions with the direct use of scanning electron microscopy (SEM) images from blast-cleaned steel substrates

Author(s):  
Tom Marquardt ◽  
Andreas W. Momber
Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 51
Author(s):  
Michela Relucenti ◽  
Giuseppe Familiari ◽  
Orlando Donfrancesco ◽  
Maurizio Taurino ◽  
Xiaobo Li ◽  
...  

Several imaging methodologies have been used in biofilm studies, contributing to deepening the knowledge on their structure. This review illustrates the most widely used microscopy techniques in biofilm investigations, focusing on traditional and innovative scanning electron microscopy techniques such as scanning electron microscopy (SEM), variable pressure SEM (VP-SEM), environmental SEM (ESEM), and the more recent ambiental SEM (ASEM), ending with the cutting edge Cryo-SEM and focused ion beam SEM (FIB SEM), highlighting the pros and cons of several methods with particular emphasis on conventional SEM and VP-SEM. As each technique has its own advantages and disadvantages, the choice of the most appropriate method must be done carefully, based on the specific aim of the study. The evaluation of the drug effects on biofilm requires imaging methods that show the most detailed ultrastructural features of the biofilm. In this kind of research, the use of scanning electron microscopy with customized protocols such as osmium tetroxide (OsO4), ruthenium red (RR), tannic acid (TA) staining, and ionic liquid (IL) treatment is unrivalled for its image quality, magnification, resolution, minimal sample loss, and actual sample structure preservation. The combined use of innovative SEM protocols and 3-D image analysis software will allow for quantitative data from SEM images to be extracted; in this way, data from images of samples that have undergone different antibiofilm treatments can be compared.


Author(s):  
Debbie G. Jones ◽  
Albert P. Pisano

A novel fabrication process is presented to create ultra thick ferromagnetic structures in silicon. The structures are fabricated by electroforming NiFe into silicon templates patterned with deep reactive ion etching (DRIE). Thin films are deposited into photoresist molds for characterization of an electroplating cell. Results show that electroplated films with a saturation magnetization above 1.6 tesla and compositions of approximately 50/50 NiFe can be obtained through agitation of the electrolyte. Scanning electron microscopy (SEM) images show that NiFe structures embedded in a 500 μm thick silicon wafer are realized and the roughening of the mold sidewalls during the DRIE aids in adhesion of the NiFe to the silicon.


2021 ◽  
Vol 21 (7) ◽  
pp. 3773-3778
Author(s):  
Keon-Young Kim ◽  
Se-Min Jeong ◽  
Chang-Yull Lee

This paper proposes a new mechanism for detecting microscopic damage of structures based on imitating the sensory organs of spiders. Therefore, it is essential to manufacture sensors that can react sensitively to the micro deformations of structures. Numerous cracks were intentionally generated to improve the sensitivity of the proposed sensor, and an increase in the gap of the crack was observed by scanning electron microscopy (SEM) observation. Electrohydrodynamic technology is used to detect deformations in a structure of depositing Ag nano paste on a polyethylene terephtha-late (PET) substrate. Ag nano lines are also observed by SEM images. The sensor is constructed as a grid structure, by forming layers patterned horizontally and vertically. An impact tester is used to verify the mechanism for structural health monitoring using the developed sensor. The resistance changes of the sensors are applied to estimate the structure’s damaged location. The intersections of the lines with varying resistance can be used to accurately detect crack initiation. The proposed mechanism is a powerful methodology for estimating and detecting microscopic deformations and damage to structures.


2020 ◽  
Vol 34 (24) ◽  
pp. 2050249
Author(s):  
L. Yoosefi ◽  
V. Setoodeh

High sensitivity and response ratio of magnetoimpedance (MI) sensors have raised interest for using them in different environments for detection of weak magnetic fields of magnetic elements even though the high dependence of the MI response to the surface condition of the MI sensor has limited its application in some environments. In this study, we investigate the effects originating from the MI measurement in moisturized air. Using scanning electron microscopy (SEM) images, it is observed that the surface of an Fe-based MI sensor has become rough and granular after the presence of moisture on its surface. Results can be useful for developing MI sensors for use in different environmental conditions.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1779 ◽  
Author(s):  
Christoph Naber ◽  
Florian Kleiner ◽  
Franz Becker ◽  
Long Nguyen-Tuan ◽  
Christiane Rößler ◽  
...  

A new method for the nuclear magnetic resonance (NMR) surface relaxivity calibration in hydrated cement samples is proposed. This method relies on a combined analysis of 28-d hydrated tricalcium silicate samples by scanning electron microscopy (SEM) image analysis and 1H-time-domain (TD)-NMR relaxometry. Pore surface and volume data for interhydrate pores are obtained from high resolution SEM images on surfaces obtained by argon broad ion beam sectioning. These data are combined with T2 relaxation times from 1H-TD-NMR to calculate the systems surface relaxivity according to the fast exchange model of relaxation. This new method is compared to an alternative method that employs sequential drying to calibrate the systems surface relaxivity.


Materials ◽  
2020 ◽  
Vol 13 (6) ◽  
pp. 1321 ◽  
Author(s):  
Bruna Sinjari ◽  
Gianmaria D’Addazio ◽  
Edit Xhajanka ◽  
Sergio Caputi ◽  
Giuseppe Varvara ◽  
...  

Adhesive restorations have been shown to guarantee excellent performance and longevity, although this comes with some disadvantages. Among these, the vulnerability of dentine to different agents has been widely evaluated. The aim of this study was to evaluate the possible penetration of impression materials into freshly cut dentine. Dentine from 27 teeth was impressed with polyether (Impregum Penta L) (nine teeth) and with polyvinyl siloxane (Aquasil Ultra LV) (nine teeth). The surface of nine teeth after the impressions were used as the control. Specifically, the extroflections caused by the imprinting of the dentinal tubules on the impression material, the so-called impression tags, were measured. Furthermore, the presence of the material inside the tubules was examined. Scanning electron microscopy analysis showed material tags for all of the experimental groups. The mean lengths (±SD) were 22.6 (±11.0) µm for polyether, 21.8 (±12.8) µm for polyvinyl siloxane and 11.3 (±7.0) µm for the tooth control, with mean diameters (±SD) of 2.8 (±0.5), 2.4 (±0.7) and 3.1 (±0.7) µm, respectively. Fractal analysis showed fractal dimensions of 1.78 (±0.03), 1.77 (±0.03) and 1.71 (±0.03), respectively. These data demonstrated that the impression materials can remain inside the dentinal tubules, which can adversely affect the adhesive procedures.


Biomolecules ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1536
Author(s):  
Ali Daraei ◽  
Marlien Pieters ◽  
Stephen R. Baker ◽  
Zelda de Lange-Loots ◽  
Aleksander Siniarski ◽  
...  

Scanning Electron Microscopy (SEM) is a powerful, high-resolution imaging technique widely used to analyze the structure of fibrin networks. Currently, structural features, such as fiber diameter, length, density, and porosity, are mostly analyzed manually, which is tedious and may introduce user bias. A reliable, automated structural image analysis method would mitigate these drawbacks. We evaluated the performance of DiameterJ (an ImageJ plug-in) for analyzing fibrin fiber diameter by comparing automated DiameterJ outputs with manual diameter measurements in four SEM data sets with different imaging parameters. We also investigated correlations between biophysical fibrin clot properties and diameter, and between clot permeability and DiameterJ-determined clot porosity. Several of the 24 DiameterJ algorithms returned diameter values that highly correlated with and closely matched the values of the manual measurements. However, optimal performance was dependent on the pixel size of the images—best results were obtained for images with a pixel size of 8–10 nm (13–16 pixels/fiber). Larger or smaller pixels resulted in an over- or underestimation of diameter values, respectively. The correlation between clot permeability and DiameterJ-determined clot porosity was modest, likely because it is difficult to establish the correct image depth of field in this analysis. In conclusion, several DiameterJ algorithms (M6, M5, T3) perform well for diameter determination from SEM images, given the appropriate imaging conditions (13–16 pixels/fiber). Determining fibrin clot porosity via DiameterJ is challenging.


2020 ◽  
pp. 16-23
Author(s):  
QI DAOZHENG ◽  
GU CONG ◽  
FU JIAJIA ◽  
WANG YAO

The clay-sand mixtures with diferent partcle sizes were prepared to investgate partcle and pore characteristcs. The microstructure characteristcs of the sand-clay mixtures were studied by the Mercury Intrusion Porosimetry (MIP) test and Scanning Electron Microscopy (SEM). Image-Pro Plus (IPP) image processing sofware was used to quantfy SEM images which investgated the micro-mechanism of structural evoluton of mixtures under diferent gradatons. The research results indicate that the units of mixtures develop from platelets and honeycomb to agglomerated and granular with the increase of sand content. The contact between partcles transits from face-face contacts to edge-face and pointface contacts. This artcle evaluated the fractal characteristc of partcle and pore structure based on the fractal theory. With the increase Circularity of the partcles, the ordered arrangement of the partcles in the mixed soil is further reduced. In general, the distributon of pores changes from intergranular pores to pores in aggregate, which provides a theoretcal basis for further study on the micro-macro correlaton of mixtures.


Sign in / Sign up

Export Citation Format

Share Document