Performance-Based Evaluation of Energy Dissipating Hysteretic Infilled Reinforced Concrete Frame Based on Cyclic Tests

Author(s):  
Nidhin S Pachappoyil ◽  
Pankaj Agarwal
2016 ◽  
Vol 32 (4) ◽  
pp. 2337-2355 ◽  
Author(s):  
Laura Redmond ◽  
Lawrence Kahn ◽  
Reginald DesRoches

Reinforced concrete buildings with masonry infill are vulnerable in earthquakes primarily because the masonry walls often fail due to out-of-plane forces and can trigger soft-story collapses. In order to prevent these failures, many engineers in the Caribbean have partially reinforced the infill walls and connected them to the reinforced concrete frame. This forms a hybrid concrete-masonry structure. Hybrid concrete-masonry structures have the potential to improve the seismic performance of many structures across the globe, as they are an easy adaptation from traditional unreinforced masonry infill. However, there is little codified guidance for this type of structure, and the influence of the masonry infill and dowel connections on the in-plane behavior of the frame is often neglected. This paper summarizes the current design and construction practices for hybrid concrete-masonry structures and assesses their seismic performance via cyclic tests on full scale test specimens. Based on the results of the experiment, a method is proposed to account for the dowel connections and the partially reinforced infill when designing hybrid concrete-masonry structures in earthquake zones.


2020 ◽  
Vol 12 (24) ◽  
pp. 10360
Author(s):  
Hyun-Do Yun ◽  
Sun-Woong Kim ◽  
Wan-Shin Park ◽  
Sun-Woo Kim

The purpose of this study was to experimentally evaluate the effect of a hinged steel damping system on the shear behavior of a nonductile reinforced concrete frame with an opening. For the experimental test, a total of three full-scale reinforced concrete frame specimens were planned, based on the “no retrofitting” (NR) specimens with non-seismic details. The main research questions were whether the hinged steel damping system is reinforced and whether torsion springs are installed in the hinged steel damping system. From the results of the experiment, the hinged steel damping system (DR specimen) was found to be effective in seismic retrofitting, while isolating the opening of the reinforced concrete (RC) frame, and the torsion spring installed at the hinged connection (DSR specimen) was evaluated to be effective in controlling the amount of deformation of the upper and lower dampers. The strength, stiffness, and energy dissipation capacity of the DSR specimen were slightly improved compared to the DR specimen, and it was confirmed that stress redistribution was induced by the rotational stiffness of the torsion spring installed in the hinge connection between the upper and lower frames.


2003 ◽  
Vol 6 (1) ◽  
pp. 15-21 ◽  
Author(s):  
Sayed A. Attaalla ◽  
Mehran Agbabian

The characteristics of the shear deformation inside the beam-column joint core of reinforced concrete frame structures subjected to seismic loading are discussed in this paper. The paper presents the formulation of an analytical model based on experimental observations. The model is intended to predict the expansions of beam-column joint core in the horizontal and vertical directions. The model describes the strain compatibility inside the joint in an average sense. Its predictions are verified utilizing experimental measurements obtained from tests conducted on beam-column connections. The model is found to adequately predict the components of shear deformation in the joint core and satisfactorily estimates the average strains in the joint hoops up to bond failure. The model may be considered as a simple, yet, important step towards analytical understanding of the sophisticated shear mechanism inside the joint and may be implemented in a controlled-deformation design technique of the joint.


2016 ◽  
Vol 711 ◽  
pp. 982-988
Author(s):  
Alex Brodsky ◽  
David Z. Yankelevsky

Numerous studies have been conducted on the in plane behavior of masonry infill walls to lateral loading simulating earthquake action on buildings. The present study is focused on a problem that has almost not been studied regarding the vertical (opposed to lateral) in-plane action on these walls. This may be of concern when a supporting column of a multi-storey reinforced concrete frame with infill masonry walls undergoes a severe damage due to an extreme loading such as a strong earthquake, car impact or military or terror action in proximity to the column. The loss of the supporting column may cause a fully or partly progressive collapse to a bare reinforced concrete frame, without infill masonry walls. The presence of the infill masonry walls may restrain the process and prevent the development of a progressive collapse. The aim of the present study is to test the in-plane composite action of Reinforced Concrete (RC) frames with infill masonry walls under vertical loading through laboratory experiments and evaluate the contributions of infill masonry walls, in an attempt to examine the infill masonry wall added resistance to the bare frame under these circumstances. Preliminary results of laboratory tests that have been conducted on reinforced concrete infilled frames without a support at their end, under monotonic vertical loading along that column axis will be presented. The observed damages and failure modes under vertical loading are clearly different from the already known failure modes observed in the case of lateral loading.


1970 ◽  
Vol 96 (6) ◽  
pp. 1246-1250
Author(s):  
James C. Anderson ◽  
Vitelmo V. Bertero ◽  
O. A. Glogau

1983 ◽  
Vol 73 (5) ◽  
pp. 1435-1450
Author(s):  
Andrzej S. Nowak ◽  
Elizabeth L. M. Rose

Abstract This paper deals with the evaluation of seismic risk for commercial buildings in Memphis, Tennessee. The seismicity of the area is summarized, and commercial buildings are divided into categories with regard to parameters such as number of stories, year of construction, assessed value, total floor area, and structural type. The distributions of these parameters are presented in the figures. During the study, over 15 buildings were examined on site by a team of experts to evaluate their seismic resistances. The quality of the design, materials, and construction was found to be surprisingly good, particularly in those structures built since 1900. Seismic resistance is analytically evaluated for five buildings: a four-story reinforced concrete frame; a four-story steel structure with vertical trusses; a 13-story stell frame; and two multi-story reinforced concrete frames. The loadings from four sources are considered: EI Centro and Taft earthquakes in California (1940 and 1952, respectively) and the forces specified in the 1979 UBC and 1981 BOCA codes. Ratios of load to capacity are calculated. For each building considered, the expected percentage of damage is evaluated for the two earthquakes. The damage prediction is extended to all commercial buildings in Memphis.


Sign in / Sign up

Export Citation Format

Share Document