scholarly journals Dose dependence of visible range diffuse reflectivity for Si+and C+ion implanted polymers

2008 ◽  
Vol 113 ◽  
pp. 012038 ◽  
Author(s):  
S Balabanov ◽  
T Tsvetkova ◽  
E Borisova ◽  
L Avramov ◽  
L Bischoff
2008 ◽  
Vol 113 ◽  
pp. 012039 ◽  
Author(s):  
S Balabanov ◽  
T Tsvetkova ◽  
E Borisova ◽  
L Avramov ◽  
L Bischoff

Open Physics ◽  
2008 ◽  
Vol 6 (2) ◽  
Author(s):  
Limin Zhang ◽  
Xiaodong Zhang ◽  
Wei You ◽  
Zhen Yang ◽  
WenXiu Wang ◽  
...  

AbstractThe effects of Si, O, C and N ion implantation with different implantation doses on yellow luminescence (YL) of GaN have been investigated. The as-grown GaN samples used in the work were of unintentional doped n-type, and the photoluminescence (PL) spectra of samples had strong YL. The experimental results showed that YL of ion implanted samples exhibited marked reductions compared to samples with no implantation, while the near band edge (NBE) emissions were reduced to a lesser extent. The deep-level centers associated with YL may be produced in GaN films by O and C ion implantation, and identities of these deep-level centers were analyzed. It was also found that the dose dependence of YL was analogous with the one of the intensity ratios of YL to the near band edge (NBE) emission (I YL/I NBE) for ion implanted samples. The possible reason for this comparability has been proposed.


1973 ◽  
Vol 12 (7) ◽  
pp. 1092-1093 ◽  
Author(s):  
Miin-Shyong Lin ◽  
Kenji Gamo ◽  
Kohzoh Masuda ◽  
Susumu Namba

1991 ◽  
Vol 58 (21) ◽  
pp. 2360-2362 ◽  
Author(s):  
T. Motooka ◽  
O. W. Holland

Symmetry ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 125
Author(s):  
Mikhail A. Kotov ◽  
Andrey N. Shemyakin ◽  
Nikolay G. Solovyov ◽  
Mikhail Y. Yakimov

The study focused on increasing the efficiency of germicidal UV radiation by using highly diffuse reflective materials such as PTFE in irradiated cavities of UV air purifiers. In a conventional cylindrically symmetric cavity with a linear amalgam mercury lamp as UV-radiation source on the axis UV-radiation, flux directed from the lamp to the walls dropped from the axis to the periphery. To increase the UV irradiation, the walls are often made mirror-reflective, but the radiation flux distribution remained radially symmetric with a maximum on the source emitting surface in this case as well. When most of the emitted light is returned to the source after one reflection, the conditions of its operation are disturbed. If the walls are made of highly diffuse reflective materials, the radiation flux density inside the cavity increases on average, and its distribution becomes uniform and highly symmetric. Thus, the effect of amplification of the radiation flux due to the highly diffuse reflectivity of the walls increases with radius and reaches a maximum at the wall. Experiments were performed to demonstrate increasing amplification of germicidal UV radiation flux with a diffuse reflection coefficient in cylindrical cavities with walls of PTFE and ePTFE. The irradiation of the cavity wall was observed to increase up to 20 times at the resonant mercury line of 253.7 nm and up to 40 times at some non-resonant lines of the visible range due to highly diffuse reflectivity of the cavity walls. The flux amplification effect was limited by the diffuse reflectivity value of the walls and absorption coefficient of the radiation emitting surface. A formula for calculating the radiation flux amplification factor in a diffusely reflecting cylindrically symmetric cavity was derived for the case of Lambertian source and reflector, including wall reflectivity and source surface absorption coefficients. The effects of heating and cooling of the mercury lamp amalgam directly affected the amplification, and symmetrization of germicidal irradiation was observed and is discussed in the paper. Numerical calculations were performed by the ray tracing method. The calculated model was verified by comparing the numerical results with those of both the approximate theoretical consideration and experiments. The promising use of diffusely reflecting cylindrical cavities for UV air purifiers is discussed. Designs of air inlet and outlet ports that allow effective locking of germicidal radiation inside the UV air purifiers were considered. The results of this work may be of interest for further developments in the UV disinfection technique.


2009 ◽  
Vol 404 (23-24) ◽  
pp. 4820-4822 ◽  
Author(s):  
T.E. Mølholt ◽  
R. Mantovan ◽  
H.P. Gunnlaugsson ◽  
K. Bharuth-Ram ◽  
M. Fanciulli ◽  
...  

1977 ◽  
Vol 30 (7) ◽  
pp. 322-323 ◽  
Author(s):  
C. E. Christodoulides ◽  
W. A. Grant ◽  
J. S. Williams

Sign in / Sign up

Export Citation Format

Share Document