scholarly journals Research on application and thermal performance of raw earth material in building envelope

2021 ◽  
Vol 1777 (1) ◽  
pp. 012041
Author(s):  
Y K Yan ◽  
Y F Song
2021 ◽  
pp. 111342
Author(s):  
Zhenglai Shen ◽  
Adam L. Brooks ◽  
Yawen He ◽  
Som S. Shrestha ◽  
Hongyu Zhou

2021 ◽  
Vol 23 (09) ◽  
pp. 277-287
Author(s):  
Ashraf Mohamed Heniegal ◽  
◽  
Omar Mohamed Omar Ibrahim ◽  
Nour Bassim Frahat ◽  
Mohamed Amin ◽  
...  

Energy improvement techniques for buildings are among the modern studies that concentrate on new techniques and methods of saving energy and improving the thermal performance in buildings. This research aims to prepare microencapsulated-PCMs (micro-PCMs) by using local materials and studied the influence of using micro-PCMs on thermal performance improvement and PCMs leakage problems improvement. The micro-PCMs of paraffin wax were prepared as the core PCMs materials while the melamine-formaldehyde polymer as the shell. The micro-PCMs were characterized through scanning electron-microscopy (SEM), energy-dispersive X-ray (EDX) spectrometry, Fourier-transform infrared spectroscopy, and differential scanning calorimetry. Analysis results showed the prepared micro-PCMs present a regular spherical shape and confirm that the formation composite of the shell effectively encapsulated the cores. Furthermore, the absence of chemical interaction between the MF and the PW components. The micro-PCM have potential for architectural applications in the building-envelope to store thermal energy, provide indoor-temperature at the comfortable range, and reduce the consumption energy in buildings.


Arsitektura ◽  
2018 ◽  
Vol 16 (1) ◽  
pp. 129
Author(s):  
Sri Yuliani ◽  
Wiwik Setyaningsih

<p class="Abstract"><em>The surface temperature of the building material may release a heat load in the micro-environment. The largest building envelope receives the heat load of solar radiation is the roof. The strategic roof position at the top of the building has the opportunity to radiate heat received into the environment. Heat emissions lead to rising temperatures, so it is necessary to lower the temperature in micro-environment. When the heat of the building is not lowered will lead to an increase in the urban heat island (UHI). The objective of the study was to find the relationship between the thermal performance of the roof of the building and the energy efficiency in the high-rise building, in order to establish efficient thermal comfort. The research method uses experimental way in real model which is in Surakarta City, as humid tropical climate area. The result of the study is a comparison of the heat performance of three roofing materials which would later recommend the criteria of energy efficient roof for high buildings.</em><em></em></p>


2016 ◽  
Vol 835 ◽  
pp. 416-422
Author(s):  
Fahanim Abdul Rashid ◽  
Asrul Mahjuddin Ressang Aminuddin ◽  
Norafida Ab. Ghaffar

Over the past decade many studies were conducted to investigate the thermal performance of terraced houses in Malaysia. It was found that this housing typology failed to address the need for thermal comfort and alternatives to the narrow frontage with deep plan have been proposed with simulated good thermal performance. Although this is good progress for new generation of terraced houses, millions of units of terraced houses are still in use and new units with the outdated existing plans continued to get built due to consistently very high demand due to progressive urbanisation and rapid economic developments. Therefore, it is imperative that the thermal comfort issue for existing terraced houses is dealt with and through this paper a comparison between single and double storey terraced houses is made through analysis of indoor environmental monitoring (ambient temperature, relative humidity and air velocity) of two (2) selected case studies in Merlimau, Melaka. Contrary to popular belief, it is found that there is no statistical difference between both sets of indoor temperature and relative humidity between the case studies. This finding is indicative of the consistent and stable temporal temperature highs and lows in a 24 hour cycle despite the difference in indoor volume and distance between the ground floor and the roof cavity. Much of the reason is due to the materiality of the terraced houses construction and unsealed and uninsulated building envelope. Therefore, further research into improving the thermal performance of existing terraced houses of any typology have to be conducted to allow thermal comfort and to reduce reliance on high energy consuming air-conditioning.


2020 ◽  
Vol 214 ◽  
pp. 109846 ◽  
Author(s):  
Beñat Arregi ◽  
Roberto Garay-Martinez ◽  
Julen Astudillo ◽  
Miriam García ◽  
Juan Carlos Ramos

2018 ◽  
Vol 149 ◽  
pp. 02097
Author(s):  
LAMRANI Abdelghafour ◽  
SAFAR Said ◽  
ROUGUI Mohamed

In this work, we present a parametric study of a new administrative building, located in El-Ksar El Kebir region (Morocco). In order to have a building that complies with the RTCM in a technically and economically sound manner, we have carried out a number of interventions to insulate the components of the building, namely external walls, exposed roofs and openings. In this perspective, we have modelled the building envelope as a multi-zone building in TRNSYS and we have adopted an occupation scenario for this type of building. After determining the optimal insulation solutions, we simulated the administrative building in the five other thermal zones, to determine its feasibility in the latter.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 586 ◽  
Author(s):  
Ziwen Liu ◽  
Qian Wang ◽  
Vincent J.L. Gan ◽  
Luke Peh

Building Information Modeling (BIM) and sustainable buildings are two future cornerstones of the Architectural, Engineering and Construction (AEC) industry. In Singapore’s context, the Green Mark (GM) scoring system is prevalently used to assess the sustainability index of green buildings. BIM provides the semantic and geometry information of buildings, which is proliferated as the technological and process backbone for the green building assessment. This research, through vast literature reviews, identified that the current procedure of achieving a Green Mark score is tedious and cumbersome, which hampers productivity, especially in the calculation of building envelope thermal performance. Furthermore, the project stakeholders work in silos, in a non-collaborative, manual and 2D-based environment for generating relevant documentation to achieve the requisite green mark score. To this end, a cloud-based BIM platform was developed, with the aim of encouraging project stakeholders to collaboratively generate the project’s green mark score digitally in accordance with the regulatory requirements. Through this research, the authors have validated the Envelope Thermal Transfer Value (ETTV) calculation, which is one of the prerequisite criteria to achieve a Green Mark score, through a case study using the developed cloud-based BIM platform. The results indicated that using the proposed platform enhances the productivity and accuracy as far as ETTV calculation is concerned. This study provides a basis for future research in implementing the proposed platform for other criteria under the Green Mark Scheme.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2978 ◽  
Author(s):  
Elisabete R. Teixeira ◽  
Gilberto Machado ◽  
Adilson de P. Junior ◽  
Christiane Guarnier ◽  
Jorge Fernandes ◽  
...  

The present research is focused on an experimental investigation to evaluate the mechanical, durability, and thermal performance of compressed earth blocks (CEBs) produced in Portugal. CEBs were analysed in terms of electrical resistivity, ultrasonic pulse velocity, compressive strength, total water absorption, water absorption by capillarity, accelerated erosion test, and thermal transmittance evaluated in a guarded hotbox setup apparatus. Overall, the results showed that compressed earth blocks presented good mechanical and durability properties. Still, they had some issues in terms of porosity due to the particle size distribution of soil used for their production. The compressive strength value obtained was 9 MPa, which is considerably higher than the minimum requirements for compressed earth blocks. Moreover, they presented a heat transfer coefficient of 2.66 W/(m2·K). This heat transfer coefficient means that this type of masonry unit cannot be used in the building envelope without an additional thermal insulation layer but shows that they are suitable to be used in partition walls. Although CEBs have promising characteristics when compared to conventional bricks, results also showed that their proprieties could even be improved if optimisation of the soil mixture is implemented.