scholarly journals Application of the SENSE Algorithm to Multimodal Switchable Metasurface Imaging

2021 ◽  
Vol 2015 (1) ◽  
pp. 012133
Author(s):  
P Seregin ◽  
E Kretov ◽  
K Smolka ◽  
M Zubkov

Abstract This work aims to provide a way of performing parallel imaging with a single-channel variable-frequency resonant device. Different spatial sensitivity profiles required for SENSE reconstruction are achieved by switching between the device eigenmodes. A device capable of such switching is manufactured and several k-spaces are acquired using the device different eigenmodes. The k-spaces are then subject to downsampling to obtain the sensitivity profiles of each eigenmode and then - to perform SENSE-based reconstruction of the unaliased images with different acceleration factors.

Diagnostics ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 61
Author(s):  
Jun Lv ◽  
Chengyan Wang ◽  
Guang Yang

In this study, we proposed a model combing parallel imaging (PI) with generative adversarial network (GAN) architecture (PIC-GAN) for accelerated multi-channel magnetic resonance imaging (MRI) reconstruction. This model integrated data fidelity and regularization terms into the generator to benefit from multi-coils information and provide an “end-to-end” reconstruction. Besides, to better preserve image details during reconstruction, we combined the adversarial loss with pixel-wise loss in both image and frequency domains. The proposed PIC-GAN framework was evaluated on abdominal and knee MRI images using 2, 4 and 6-fold accelerations with different undersampling patterns. The performance of the PIC-GAN was compared to the sparsity-based parallel imaging (L1-ESPIRiT), the variational network (VN), and conventional GAN with single-channel images as input (zero-filled (ZF)-GAN). Experimental results show that our PIC-GAN can effectively reconstruct multi-channel MR images at a low noise level and improved structure similarity of the reconstructed images. PIC-GAN has yielded the lowest Normalized Mean Square Error (in ×10−5) (PIC-GAN: 0.58 ± 0.37, ZF-GAN: 1.93 ± 1.41, VN: 1.87 ± 1.28, L1-ESPIRiT: 2.49 ± 1.04 for abdominal MRI data and PIC-GAN: 0.80 ± 0.26, ZF-GAN: 0.93 ± 0.29, VN:1.18 ± 0.31, L1-ESPIRiT: 1.28 ± 0.24 for knee MRI data) and the highest Peak Signal to Noise Ratio (PIC-GAN: 34.43 ± 1.92, ZF-GAN: 31.45 ± 4.0, VN: 29.26 ± 2.98, L1-ESPIRiT: 25.40 ± 1.88 for abdominal MRI data and PIC-GAN: 34.10 ± 1.09, ZF-GAN: 31.47 ± 1.05, VN: 30.01 ± 1.01, L1-ESPIRiT: 28.01 ± 0.98 for knee MRI data) compared to ZF-GAN, VN and L1-ESPIRiT with an under-sampling factor of 6. The proposed PIC-GAN framework has shown superior reconstruction performance in terms of reducing aliasing artifacts and restoring tissue structures as compared to other conventional and state-of-the-art reconstruction methods.


Author(s):  
P. Trebbia ◽  
P. Ballongue ◽  
C. Colliex

An effective use of electron energy loss spectroscopy for chemical characterization of selected areas in the electron microscope can only be achieved with the development of quantitative measurements capabilities.The experimental assembly, which is sketched in Fig.l, has therefore been carried out. It comprises four main elements.The analytical transmission electron microscope is a conventional microscope fitted with a Castaing and Henry dispersive unit (magnetic prism and electrostatic mirror). Recent modifications include the improvement of the vacuum in the specimen chamber (below 10-6 torr) and the adaptation of a new electrostatic mirror.The detection system, similar to the one described by Hermann et al (1), is located in a separate chamber below the fluorescent screen which visualizes the energy loss spectrum. Variable apertures select the electrons, which have lost an energy AE within an energy window smaller than 1 eV, in front of a surface barrier solid state detector RTC BPY 52 100 S.Q. The saw tooth signal delivered by a charge sensitive preamplifier (decay time of 5.10-5 S) is amplified, shaped into a gaussian profile through an active filter and counted by a single channel analyser.


Author(s):  
Lee H. Veneklasen

This paper discusses some of the unique aspects of a spectroscopic emission microscope now being tested in Clausthal. The instrument is designed for the direct parallel imaging of both elastic and inelastic electrons from flat surfaces. Elastic contrast modes of the familiar LEEM include large and small angle LEED, mirror microscopy, backscatter diffraction contrast (for imaging of surface structure), and phase contrast (for imaging of step dynamics)(1). Inelastic modes include topology sensitive secondary, and work function sensitive photoemission. Most important, the new instrument will also allow analytical imaging using characteristic Auger or soft X-ray emissions. The basic instrument has been described by Bauer and Telieps (2). This configuration has been redesigned to include an airlock, and a LaB6 gun, triple condensor lens, magnetic objective lens, a double focussing separator field, an imaging energy analyzer, and a real time image processor.Fig. 1 shows the new configuration. The basic beam voltage supply Vo = 20 KV, upon which separate supplies for the gun Vg, specimen Vs, lens electrode Vf, and analyzer bias Vb float. The incident energy at the sample can be varied from Vs = 0-1 KV for elastic imaging, or from Vg + Vs = (3 + Vs) KV for inelastic imaging. The image energy window Vs±V/2 may be varied without readjusting either the illumation, or imaging/analyzer optics. The diagram shows conjugate diffraction and image planes. The apertures defining incoming Humiliation and outgoing image angles are placed below the separator magnet to allow for their independent optimization. The instrument can illuminate and image 0.5-100 μm fields at 0-1 keV emission energies with an energy window down to 0.2 eV.


1968 ◽  
Vol 11 (1) ◽  
pp. 189-193 ◽  
Author(s):  
Lois Joan Sanders

A tongue pressure unit for measurement of lingual strength and patterns of tongue pressure is described. It consists of a force displacement transducer, a single channel, direct writing recording system, and a specially designed tongue pressure disk, head stabilizer, and pressure unit holder. Calibration with known weights indicated an essentially linear and consistent response. An evaluation of subject reliability in which 17 young adults were tested on two occasions revealed no significant difference in maximum pressure exerted during the two test trials. Suggestions for clinical and research use of the instrumentation are noted.


VASA ◽  
2009 ◽  
Vol 38 (1) ◽  
pp. 66-71 ◽  
Author(s):  
Schubert

We describe a case of aortic coarctation at the level of the infrarenal abdominal aorta which is encountered in less than six individuals in one million. In contrast to aortic narrowing above or including the renal arteries, this seems to be a relatively benign anomaly without systemic hypertension or impaired renal function. For the first time in this type of anomaly, contrast-enhanced MR angiography (ce-MRA) on a multi-receiver channel MR system, with an 8-channel phased array coil and parallel imaging was used. Ce-MRA displayed a tortuous, narrowed aortic segment that was found to be associated with mesenteric artery stenosis and compression of the orthotopic left renal vein, also known as the nutcracker phenomenon. All major aortic branches could be depicted using 3D surface-shaded displays and subvolume maximum intensity projections (MIPs). Collateral vessels of the abdominal wall were identified using whole-volume MIPs. Since the majority of aortic malformations are diagnosed at a younger age, and many suffer from renal insufficiency, we conclude that ce-MRA will eventually place conventional DSA as the modality of choice in malformations of the abdominal aorta.


Sign in / Sign up

Export Citation Format

Share Document