scholarly journals Development of the method of determining the location of a short circuit in transmission lines

2021 ◽  
Vol 2061 (1) ◽  
pp. 012033
Author(s):  
K Suslov ◽  
N Solonina ◽  
Z Solonina ◽  
A Akhmetshin

Abstract One of the serious problems of the reliable functioning of energy systems is the disruption of the performance of overhead and cable transmission power lines caused by various reasons. Most of the power outages occur in distribution networks. Particularly dangerous short-circuits in the supply and distribution network, due to unpredictable natural disasters. To ensure uninterrupted and reliable power supply to consumers, it is necessary to identify and eliminate the malfunction in a short time to reduce damage. Finding and troubleshooting a line is an important task. The authors proposed a method for quickly determining the location of a short circuit in power lines. The proposed method allows to reduce search time and increase the accuracy of determining the fault location.

2020 ◽  
Vol 178 ◽  
pp. 01057
Author(s):  
Olga Ahmedova ◽  
Anatoliy Soshinov ◽  
Natalia Shevchenko

Devices of fault location are widespread in electrical grids. In overhead power lines of voltages of 10 kV and higher, such devices are based on measurements of parameters in emergency mode. These devices can be divided into two main groups: designed to determine fault location of short circuits and of ground short circuit. In both cases, when detecting fault location, analyzed are not only the current and voltage parameters at the accident time, but also the parameters of overhead power line. When analyzing equivalent circuits of power lines, approximate tabular values of direct and quadrature parameters are used. It was revealed, that the line parameters are significantly affected by external atmospheric factors: ambient temperature, soil moisture, wind strength and direction, ice formation, etc. To accurately determine the fault location, it is necessary to evaluate the influence of these factors on the linear parameters of the overhead line. The paper presents analysis of the influence of changes in atmospheric factors on parameters of overhead power line. A methodology for calculating the operation setpoints of the device for fault location in power line is given.


2011 ◽  
Vol 121-126 ◽  
pp. 1269-1273
Author(s):  
Wen Xiu Tang ◽  
Mo Zhang ◽  
Ying Liu ◽  
Xu Fei Lang ◽  
Liang Kuan Zhu

In this paper, a novel method is investigated to detect short-circuit fault signal transmission lines in strong noise environment based on discrete wavelet transform theory. Simulation results show that the method can accurately determine the fault position, can effectively analyze the non-stationary signal and be suitable for transmission line fault occurred after transient signal detection. Furthermore, it can effectively eliminate noise effects of fault signal so as to realize the transmission lines of accurate fault.


2020 ◽  
Vol 14 (1) ◽  
pp. 21-26
Author(s):  
S. SKRYPNYK ◽  
◽  
A. SHEINA ◽  

Most failures in electrical installations are caused by short circuits (short circuits), which occur as a result of a failure in the electrical strength of the insulation of the conductive parts. A short circuit is an electrical connection of two points of an electric circuit with different values of potential, which is not provided by the design of the device, which interferes with its normal operation. Short circuits may result from a failure of the insulation of the current-carrying elements or the mechanical contact of the non- insulated elements. Also called a short circuit is a condition where the load resistance is less than the internal resistance of the power source. The reasons for such violations are various: aging of insulation, breakages of wires of overhead transmission lines, mechanical damages of isolation of cable lines at ground works, lightning strikes in the transmission line and others. Most often, short-circuits occur through transient resistance, such as through the resistance of an electric arc that occurs at the point of damage to the insulation. Sometimes there are metallic short circuits in which the resistance of the electric arc is very small. The study of short circuits in the power grid is a major step in the design of modern electrical networks. The research is conducted using computer software, first by modeling the system and then simulating errors. A malfunction usually leads to an increase in the current flowing in the lines, and failure to provide reliable protection can result in damage to the power unit. Thus, short-circuit calculations are the primary consideration when designing, upgrading, or expanding a power system. The three-phase short circuit is the least likely. However, in many cases, the three-phase short circuit is associated with the most severe consequences, as it causes the highest power imbalances on the shafts of the generators. The study of transients begins with the mode of three-phase closure due to its relative simplicity in comparison with other types of asymmetry. In most cases, the analysis and calculation of the transient regime of the electrical system involves the preparation of a calculated scheme of substitution, in which the parameters of its elements are determined in named or relative units. The electrical substitution circuitry is used to further study the transients in the power system. The definition of electrical and electromagnetic quantities in relative units is widely used in the theory of electric machines. This is because it significantly simplifies the theoretical calculations and gives the results a generalized view in the practical calculations of currents and residual voltages at the short circuit. By the relative value of any value is understood as its relation to another value of the same name, taken as the base. So, before presenting any quantities in relative units, we need to choose the basic units. In the electrical system with increased voltages, the overall load capacity of the network increases, which in turn makes it possible to supply high-quality electrical energy over a greater distance. In the process of comparing the type of transmission lines, it should be noted that the advantages of the cable transmission line. According to the results of the calculation of short-circuit currents, it can be concluded that in networks with a larger line cross-section and a higher voltage, the short-circuit currents are larger. Thus, during the transition of the electric networks to the higher voltage class of 20 kV, the currents of the KZ increased by 43% compared to the 6 kV electric network. This analysis shows that the importance of reliable power supply in the power supply system for high voltage classes must be high and have equipment to prevent emergencies. In the future, it is planned to develop a systematic calculation of short-circuit currents for a number of transmission lines and to conduct mathematical modeling in the system of applications for the study of transient processes at short circuits.


2013 ◽  
Vol 340 ◽  
pp. 819-823
Author(s):  
Yu Jun Zhang ◽  
Jing Li

The low-voltage distribution networks have some structural features, such as short supply line, more lines branch and influence of transition resistance of the short-circuit current. These characteristics seriously affect the development of fault location technology. The paper, based on the basis of the structural features about the low-voltage distribution networks, create the distribution networks of description matrix by knowledge of mathematical topology and use the distribution network fault location algorithm based on web-based structure matrix. By the algorithm, the area of fault judgment and the actual distribution network fault location are fully consistent. The new theory provides a new way of thinking for fault location in low-voltage distribution networks.


2021 ◽  
Vol 11 (1) ◽  
pp. 405
Author(s):  
Daniel Alcala-Gonzalez ◽  
Eva Maria García del Toro ◽  
María Isabel Más-López ◽  
Santiago Pindado

The increase in the installation of renewable energy sources in electrical systems has changed the power distribution networks, and a new scenario regarding protection devices has arisen. Distributed generation (DG) might produce artificial delays regarding the performance of protection devices when acting as a result of short-circuits. In this study, the preliminary research results carried out to analyze the effect of renewable energy sources (photovoltaic, wind generation, etc.) on the protection devices of a power grid are described. In order to study this problem in a well-defined scenario, a quite simple distribution network (similar to the ones present in rural areas) was selected. The distribution network was divided into three protection zones so that each of them had DG. In the Institute of Electrical and Electronic Engineers (IEEE) system 13 bus test feeder, the short-circuits with different levels of penetration were performed from 1 MVA to 3 MVA (that represent 25%, 50%, and 75% of the total load in the network). In the simulations carried out, it was observed that the installation of DG in this distribution network produced significant changes in the short-circuit currents, and the inadequate performance of the protection devices and the delay in their operating times (with differences of up to 180% in relation to the case without DG). The latter, that is, the impacts of photovoltaic DG on the reactions of protection devices in a radial distribution network, is the most relevant outcome of this work. These are the first results obtained from a research collaboration framework established by staff from ETSI Civil and the IDR/UPM Institute, to analyze the effect of renewable energy sources (as DG) on the protection devices of a radial distribution network.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4729
Author(s):  
Rafał Tarko ◽  
Jakub Gajdzica ◽  
Wiesław Nowak ◽  
Waldemar Szpyra

The article deals with the problems of single-phase short-circuit current distribution in overhead power lines. Short-circuit disturbances cause many negative phenomena in power networks. Since experimental studies of short-circuits in real networks are practically impossible to perform, these effects can be evaluated only theoretically, based on short-circuit current calculations with the use of appropriate mathematical models. Although short-circuit modeling is considered to be one of the simplest power system calculations, the exact mathematical description of the phenomena occurring at short-circuits is complex. Simplified normative methods are often used for short-circuit current calculations; however, this does not give ground for a thorough analysis of short-circuit current distribution in power lines. The distributions are analyzed using power line models with different degrees of complexity in line with the assumptions made for a given model. The paper presents the problem of current distribution analysis in high-voltage overhead lines for single-phase faults to the tower structures. Simulation studies were conducted on the models developed for the calculation of short-circuit currents in the high-voltage power line earthing. The objective of the analysis was to assess the validity of simplification assumptions followed by practical recommendations on the applicability of the models.


Author(s):  
Prof. Sayyad Naimuddin ◽  
Prof. Nahid Khan ◽  
Vaishali Gupta ◽  
Tuba Farhat ◽  
Deepak Singh Mujeebuddin Ansari ◽  
...  

Transmission and distribution lines are used to transmit and distribute electrical power throughout load center. The problem with these lines are, because the loads are unbalanced and their attraction towards various faults as a results of lightning, short circuits, faulty equipment’s, miss-operation, human errors, overload, and aging. To avoid this case and that we need the precise location of fault occurrence. To avoid this situation, we need the exact location of fault occurrence. This problem is handled by a set of resistors representing cable length in KMs and fault creation is made by a set of switches at every known KM to cross check the accuracy of the same. Only way to solve this problem is to come up with a mechanism that can detect the fault in an electricity transmission line automatically and intimate the authorities with a precise location. Through this project we develop a device that uses sensors to sense the incoming & outgoing values and detect healthy and faulty condition. And, the system will be integrated with IoT mechanism, to intimate the responsible people real time with the location information. Moreover technical losses occur naturally and are caused because of power dissipation in transmission lines, transformers, and other equipments. The system prevents the illegal usage of electricity.


2021 ◽  
Vol 24 (1) ◽  
pp. 69-72
Author(s):  
SKRYPNYK S. ◽  

In the current global economic crisis and acute shortage of energy resources, increasing importance is attached to energy saving measures, economical and careful consumption of raw materials, materials, electricity and heat, environmental safety of industrial production. During the reconstruction of existing power supply systems of industrial enterprises, modern progressive solutions should be considered and implemented, morally and physically obsolete electrical equipment should be replaced, namely the introduction of new electrical equipment for transition from 6/10 kV to 20 kV in Ukrainian power systems. It is also necessary to pay attention to the improvement of power supply circuits and distribution networks, the implementation of complex automation of complex technological processes, rational compensation of reactive power at all levels of power supply systems. In the power system, the main transport link is the power line. Power lines (transmission lines) are long conductors suspended at a safe distance from the ground overhead lines (overhead lines) or cable lines (overhead lines) in which conductors are insulated from each other and from the environment and protected by insulation and armor electricity. Power lines are the most massive elements of the power supply system, they connect the individual nodes of its circuit. Longitudinal and transverse parameters are distinguished in alternative schemes. The load current flows through the longitudinal parameters, voltage is applied to the transverse ones. The replacement circuit of the electrical network consists of replacement circuits of the following elements: power lines, transformers, reactors, capacitors, loads, power sources. Calculating the steady-state modes of power systems, the substitution schemes of the elements are given in a single-line design, because the parameters of all phases are symmetrical. In local and local electrical networks with a relatively short length and low rated voltage, the conduction currents are small compared to load currents. Therefore, in typical electrical calculations of these networks, the capacitive conductivity of the lines is not taken into account. However, for these networks, the accounting of capacitive conductivities is necessary when considering some modes, the existence of which in itself is due only to the presence of capacitive conductivities. For example, the mode of single-phase ground fault in a network with isolated or compensated neutral or analysis of the modes of operation of neutrals of electrical networks of different voltage classes cannot be performed without taking into account the capacitive conductivity of these networks. When switching the power system of Ukraine to the nominal voltage of 20 kV, it should be taken into account that the transmission line will be replaced in the sections of both the overhead power line and cable power line, namely 35, 10, 6 kV. The replacement scheme must describe all the characteristics and properties of the elements of cable and overhead lines in accordance with real conditions. Thus, it is not expedient to use simplified substitution circuits that neglect energy parameters and properties of conductors to study the parameters of transmission lines. The use of a complete "P" -shaped scheme for the analysis of the parameters of transmission lines and transmission lines for a voltage of 20 kV is the basis of mathematical modeling of the transmission system in the distribution networks of our country.