scholarly journals IEA EBC Annex 68 – Consequences on ventilation and hygrothermal operation of buildings

2021 ◽  
Vol 2069 (1) ◽  
pp. 012184
Author(s):  
C. Rode ◽  
D. Zukowska ◽  
J. Kolarik

Abstract The objective of the IEA EBC Annex 68 Project, “Indoor Air Quality Design and Control in Low Energy Residential Buildings”, has been to develop the fundamental basis for optimal design and control strategies for good Indoor Air Quality (IAQ) in highly energy efficient residential buildings. Focus has been on emission of chemical pollutants from building products and use of ventilation to alleviate IAQ effects. The question has been whether new paradigms for demand control should be developed based on knowledge from this project. The paper gives an overview of the project’s activities with regards to: - Gathering of laboratory and field data on pollution sources in buildings. - Formulation of a so-called “similarity approach” to predict emissions of volatile organic compounds based on knowledge from moisture transfer properties. - Gathering of a set of contemporary models to simulate the combined heat, air, moisture and pollution conditions of buildings and their assemblies. Based on this background, the project has identified and described an extended set of amenable ways to optimize the provision of ventilation and air-conditioning and to assess possibilities to bring this knowledge into practice. The paper gives an overview of the suggested solutions and their conditions.

Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 250
Author(s):  
Chuloh Jung ◽  
Jihad Awad

Due to unprecedented urbanization, UAE had built many new residential projects with poor choices of material and ventilation. This social phenomenon is leading UAE to Sick Building Syndrome (SBS) faster than any other countries. The Dubai Municipality regulates the indoor air quality with strict stipulation, but the detailed regulations are still insufficient. The objective of this paper is to measure the indoor air quality of new residential projects in Dubai to suggest the improvement of the regulations for indoor air quality. As a methodology, a field survey was conducted to investigate the status of indoor air pollution in residential buildings. Based on the field survey data, lab experiments for building materials were conducted and a computer simulation on radon gas was conducted. The result had shown that radon gas was mainly detected in new townhouses and labor camp houses, and its concentration was found to exceed the standard. Volatile organic solvents (VOCs) and formaldehyde (CH2O) were mainly detected in showhouses and new townhouses, and the concentration distribution was about 10 times higher than that of outdoors. It was proven that emission concentration of radon gas from various building materials were detected, and the order was red clay, gypsum board, and concrete. Volatile organic solvents (VOCs) are mainly detected in oil paints and PVC floor and the radiation amount of all pollutants increased with temperature increase. In computer simulation, it was found that a new townhouse needs a grace period from 20 days to 6 months to lower the radon gas concentration by 2 pCi/L. This study will serve as a basic data to establish more detailed regulation for the building materials and improve the IAQ standards in Dubai.


2020 ◽  
pp. 1420326X2096076
Author(s):  
Pedro F. Pereira ◽  
Nuno M. M. Ramos

In Portugal, residential buildings commonly have their ventilation strategy changed after commissioning. This occurs due to the building managers' willingness to reduce shared costs with the electricity needed for fan operation. However, this option is not technically supported, and the effects of such a strategy on indoor air quality-related to human pollutants are yet to be quantified. CO2 was monitored in 15 bedrooms and air exchange rates were calculated for each room. The air exchange rate values ranged from 0.18 to 0.53 h−1 when mechanical extraction ventilation was off, and from 0.45 to 0.90 h−1 when mechanical extraction ventilation was on, which represents an average increase of 119%. With the current intermittent ventilation strategy, all rooms remain above 1500 ppm for a given percentage of time, and 12 rooms presenting CO2 concentrations above 2000 ppm. Simulations of theoretical CO2 concentrations, for a non-interrupted mechanical ventilation strategy show that no rooms would accumulate CO2 concentrations above 2000 ppm, and only 25% would present CO2 concentrations above 1500 ppm. Pearson correlations between the monitored CO2 and human and spatial factors identified two relevant parameters. Those parameters correspond to ratios between CO2 generation and floor area ([Formula: see text]), and airflow with CO2 generation ([Formula: see text]). The proposed ratios could be used as ways to optimise ventilation costs and indoor air quality.


2016 ◽  
Vol 108 ◽  
pp. 63-72 ◽  
Author(s):  
Violeta Kaunelienė ◽  
Tadas Prasauskas ◽  
Edvinas Krugly ◽  
Inga Stasiulaitienė ◽  
Darius Čiužas ◽  
...  

2019 ◽  
Vol 43 (2) ◽  
pp. 121-142
Author(s):  
Andrea Ferrantelli ◽  
Camilla Vornanen-Winqvist ◽  
Milla Mattila ◽  
Heidi Salonen ◽  
Jarek Kurnitski

Moisture excess in buildings constitutes a complex problem affecting indoor air quality, energy consumption and the lifetime of the building envelope. We investigate the effect on moisture transfer in structures as a positive pressure is applied inside the enclosure. It is found that, contrary to established belief, the positive pressure does not induce any negative effects on the structures’ moisture content in normally ventilated classrooms, even with high occupancy. Our case study consists of a school building in Finland, subject to temperature and relative humidity measurements after a small (5–7 Pa) positive pressure was realized through ventilation control. We first address analytically the moisture excess generated inside the classrooms for 14 days, using dynamical balance equations that account for both ventilation effects and occupants’ moisture release in the environment. It is found that the average moisture excess is very small, largely below 1 g/m3, even for ventilation rates that are half the design value. We also examine the moisture performance of the envelope, by addressing the moisture migration at upper and lower joints of the external walls for both measured and design values of the indoor absolute humidity (AH). A coupled numerical model of diffusion and convection shows that moisture accumulation in the envelope and the according stresses are negligible for any realistic AH values. This result is in agreement with field measurements at the school. In conclusion, it seems that applying a small overpressure in a well-ventilated school building during a standard service period resulted in no accumulation inside the external walls, even at high occupancy and with low ventilation. Remarkably, it slightly dried out the moisture content in structures under actual occupancy conditions. The positive pressure has accordingly no negative effects on moisture performance, and is capable to guarantee a good indoor air quality as well.


2019 ◽  
Vol 11 (17) ◽  
pp. 4791
Author(s):  
Kwag ◽  
Park ◽  
Kim ◽  
Kim

Building air-tightness has been increased to make energy efficient buildings. However, various indoor air quality issues can be caused by high building air-tightness because it allows low air and moisture transmission through building envelop. In order to solve and prevent these issues, mechanical ventilation systems can be used to control the indoor humidity level. The purpose of this paper is to evaluate the performances of the Relative Humidity (RH)-sensor based auto-controlled centralized exhaust ventilation systems to manage indoor air quality and thermal comfort of multi-family residential buildings in South Korea. A series of field tests were performed for different target zones and for various moisture source scenarios. As a result, it was found that the auto-controlled centralized exhaust ventilation systems were able to control indoor air quality and to maintain the zones thermal comfort faster than the baseline cases that did not operate exhaust vents. The results presented in this paper can show the potential and the feasibility of the auto-controlled centralized exhaust ventilation systems for multi-family residential buildings in South Korea. It is expected that the results presented in this paper would be useful for building owners, engineers, and architects when designing building systems.


2012 ◽  
Vol 65 (4) ◽  
pp. 773-779 ◽  
Author(s):  
Manju Sharma ◽  
Susan O'Connell ◽  
Brett Garelli ◽  
Chakkrid Sattayatewa ◽  
Demetrios Moschandreas ◽  
...  

Indoor air quality (IAQ) and odors were determined using sampling/monitoring, measurement, and modeling methods in a large dewatering building at a very large water reclamation plant. The ultimate goal was to determine control strategies to reduce the sensory impacts on the workforce and achieve odor reduction within the building. Study approaches included: (1) investigation of air mixing by using CO2 as an indicator, (2) measurement of airflow capacity of ventilation fans, (3) measurement of odors and odorants, (4) development of statistical and IAQ models, and (5) recommendation of control strategies. The results showed that air quality in the building complies with occupational safety and health guidelines; however, nuisance odors that can increase stress and productivity loss still persist. Excess roof fan capacity induced odor dispersion to the upper levels. Lack of a local air exhaust system of sufficient capacity and optimum design was found to be the contributor to occasional less than adequate indoor air quality and odors. Overall, air ventilation rate in the building has less effect on persistence of odors in the building. Odor/odorant emission rates from centrifuge drops were approximately 100 times higher than those from the open conveyors. Based on measurements and modeling, the key control strategies recommended include increasing local air exhaust system capacity and relocation of exhaust hoods closer to the centrifuge drops.