scholarly journals Reduced dimension model for heat transfer of ground heat exchanger in permafrost

2017 ◽  
Vol 937 ◽  
pp. 012056
Author(s):  
M Vasilyeva ◽  
S Stepanov ◽  
I Sirditov
2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


2012 ◽  
Vol 516-517 ◽  
pp. 316-321
Author(s):  
Zhong Yi Yu ◽  
Yan Hua Chen ◽  
Xiao Liang Tang ◽  
Jian Ping Lei

According to the application conditions of horizontal ground heat exchanger(HGHE) under artificial lake, this paper uses numerical simulation method to do dynamic simulation research of the heat transfer performance of HGHE, analyzes the effect of connection mode and pipe flow velocity on heat transfer performance of HGHE in detail,puts forward efficient HGHE loop formation mode,and will provide effective technical support for ground-source heat pump system design with HGHE.


2012 ◽  
Vol 53 ◽  
pp. 137-144 ◽  
Author(s):  
Hyunku Park ◽  
Seung-Rae Lee ◽  
Seok Yoon ◽  
Hosung Shin ◽  
Dae-Soo Lee

2014 ◽  
Vol 945-949 ◽  
pp. 2820-2824 ◽  
Author(s):  
Li Bai ◽  
Peng Xuan Wang

For the case of ground-source heat pump in severe cold regions in winter, the heat transfer situation of the ground and ground heat exchanger was dynamically simulated according to the statistics of a project in Changchun to analysis the change of the ground heat, which provided references for the initial design and operation and management of the ground-coupled heat pump in severe cold regions.


Energies ◽  
2020 ◽  
Vol 13 (6) ◽  
pp. 1344
Author(s):  
Mehrdad Massoudi

This Special Issue of Energies is dedicated to all aspects of fluid flow and heat transfer in geothermal applications, including the ground heat exchanger, conduction, and convection in porous media [...]


2013 ◽  
Vol 65 ◽  
pp. 231-241 ◽  
Author(s):  
Pingfang Hu ◽  
Zhongyi Yu ◽  
Na Zhu ◽  
Fei Lei ◽  
Xudong Yuan

2014 ◽  
Vol 580-583 ◽  
pp. 2488-2491
Author(s):  
Rong Hui Wang ◽  
Qing Hua Wang ◽  
Ye Feng

5 radial heat exchange wells were designed, and the different angle drilling, drilling pipe, and grouting backfill construction technology was studied. In addition, the heat transfer performance of the buried radial heat exchange wells was tested. The results show that, design of pipe equipment is feasible, construction is convenient, and the ratio of backfill material is reasonable; the heat transfer performance of 90 °buried tube is the best. The smaller the angle with the ground heat exchanger, the greater the heat exchange performance is affected by the surface temperature.


2020 ◽  
Vol 38 (4) ◽  
pp. 845-862
Author(s):  
Saif Nawaz Ahmad ◽  
Om Prakash

Earth air tube heat exchanger (EATHE) is one of the passive technologies which utilize the earth stored heat (renewable energy) for heating/cooling the buildings. EATHE releases heat to earth for cooling space in summer, making the earth a heat sink and extracts earth-stored energy for heating space in winter and makes the earth a heat source. This paper optimizes the Length of the ground heat exchanger and overall heat transfer coefficient of earth air heat exchanger using the Taguchi technique for cooling application. For this purpose, we select six factors such as installation depth of Pipe (A), Pipe's inner diameter (B), Thermal conductivity of pipe material (C), Inlet air temperature (D), Outlet air temperature (E), Inlet air velocity (F). All these factors are taken at three levels, and we select an L27 orthogonal array for experimental runs. The ground heat exchanger's Length and the overall heat transfer coefficient were then calculated for each experimental run. In the Taguchi method, we find the signal to noise ratio for an optimal combination of all six factors and ANOVA to find the order of influencing parameters and their percentage contributions for both the objective parameters. According to our results, the best combination for all the six factors for ground heat exchanger length and overall heat transfer coefficient were A1B1C3D1E3F1 and A2B3C2D3E1F3, respectively. The highest and lowest influencing factors for ground heat exchanger length were the pipe's inner diameter and the pipe's installation depth with their contribution factors of 69.12 and 0.32%, respectively. In contrast, the highest and lowest influencing factors for the overall heat transfer coefficient were the pipe's inner diameter and thermal conductivity of pipe material with their contribution factors of 75.97and 0%, respectively. Hence the order of influence of all the six factors for both the objective parameters was BEFDCA.


Sign in / Sign up

Export Citation Format

Share Document