Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.

1984 ◽  
Vol 30 (11) ◽  
pp. 1826-1829 ◽  
Author(s):  
W H Porter ◽  
V M Haver ◽  
B A Bush

Abstract Determination of digoxin by fluorescence polarization immunoassay (FPIA) with the Abbott "TDx" is significantly influenced by the concentration of total serum protein. Each 10 g/L increase in serum protein results in an 8% decrease in measured digoxin. Studies with [3H]digoxin confirmed that digoxin binds to the protein pellet during the trichloroacetic acid precipitation step before the immunoassay. Serum protein, or equal concentrations of albumin or gamma-globulin, exert an equivalent effect on the apparent digoxin value. Because the total protein concentration of the assay calibrators is low (50 g/L) compared with its reference interval in serum (60-80 g/L), results by FPIA may be expected to be low by an average of 16% (range, 8-24%). Digoxin results by FPIA will be most nearly accurate when the calibrators include a total protein concentration of about 70 g/L. Patients' specimens with abnormally high or low protein content will give falsely high or low results for digoxin.

1962 ◽  
Vol 203 (1) ◽  
pp. 119-121 ◽  
Author(s):  
Otakar V. Sirek ◽  
Anna Sirek

Total protein-bound hexose, hexosamine, and sialic acid were determined in sera of six littermate mongrel pups at monthly intervals from the 4th day after birth up to the age of 7 months. The concentration of the individual constituents fluctuated considerably from month to month, but the values showed neither a definite trend nor a relationship to weight gain. When the carbohydrate moiety was expressed as percentage of total serum protein concentration, the values were high in newborn pups and diminished after the 1st month of life. This was due to a rise in the concentration of total serum protein, brought about by an increase of the albumin fraction which is low in carbohydrate.


1984 ◽  
Vol 30 (3) ◽  
pp. 446-449 ◽  
Author(s):  
R W Yatscoff ◽  
G J Tevaarwerk ◽  
J C MacDonald

Abstract We have evaluated an affinity-chromatographic procedure for determination of glycated albumin (GA) and glycated total serum protein (GSP). Recovery of these analytes was inversely related to free glucose concentration, thus necessitating removal of free glucose. For this we used molecular-exclusion chromatography on G-25 Sephadex, or dialysis, the latter procedure resulting in significantly (p less than 0.05) lower concentrations of GSP and GA. Total protein concentration and percent glycation are also inversely related, and so protein concentrations must be standardized before the assay. Within- and between-run CVs for both GSP and GA were less than 6.5 and 18%, respectively, the determination of GA being generally the more precise of the two. Labile glycated fractions, lipemia, icterus, hemolysis, and type of anticoagulant did not affect the results, but assay temperature did. Diabetic subjects showed substantially higher concentrations of GA and GSP than did normal subjects. Because of the life span of these analytes in circulation, their measurement may provide a short-term index of glycemic control.


2014 ◽  
Vol 27 (1) ◽  
pp. 253-257 ◽  
Author(s):  
Patrick Marcel Seumo Tchekwagep ◽  
Charles Péguy Nanseu-Njiki ◽  
Emmanuel Ngameni ◽  
Ravi Danielsson ◽  
Thomas Arnebrant ◽  
...  

1967 ◽  
Vol 45 (4) ◽  
pp. 571-575 ◽  
Author(s):  
W. F. Blatt ◽  
J. Kerkay

Total protein, serum protein, and lipoprotein electrophoretic distribution and hematocrit values were determined in two groups of men during acclimatization to 6 weeks of cold and 11 days of heat respectively. After 3 weeks of cold exposure total serum protein and albumin content decreased, while the globulin fractions increased; thus, the calculated albumin/globulin ratio was significantly depressed. During the last 2 weeks, these parameters gradually returned to control values. Overall, the protein changes during heat acclimatization were minimal, although the globulins decreased slightly, yielding a small increase in the albumin/globulin ratio. The hematocrit levels were significantly lowered during both environmental exposures, whereas the lipoprotein distribution remained essentially unchanged.


1971 ◽  
Vol 17 (4) ◽  
pp. 301-306 ◽  
Author(s):  
John Savory ◽  
M Geraldine Heintges ◽  
Robert E Sobel

Abstract An automated continuous-flow procedure has been developed for simultaneously measuring total serum protein and globulin. The method for total protein is a minor modification of an existing automated method in which the biuret reagent is used. Total globulin is measured by reaction with glyoxylic acid, and standardized with N-acetyltryptophan. An empirical factor relating concentration of N-acetyltryptophan to human globulin has been derived. Values for total serum globulin obtained by this new automated procedure correlate closely with values obtained by electrophoresis, but do not agree with values obtained by use of procedures involving binding of anionic dye. Recovery of gamma globulin added to serum is essentially quantitative; the day-to-day precision (CV) is 4.31%.


Sign in / Sign up