Intra- and interlaboratory sources of imprecision in drug measurements by different techniques

1993 ◽  
Vol 39 (5) ◽  
pp. 851-855 ◽  
Author(s):  
L M Tsanaclis ◽  
J F Wilson

Abstract We compared the intra- and interlaboratory precision of seven techniques used to measure eight antiepileptic drugs, digoxin, and theophylline by using data from the international Healthcontrol external quality-assessment scheme. Scheme participants were supplied blind with 6 or 12 sets of duplicate lyophilized serum samples. Each set contained different drug concentrations, and duplicates were analyzed separately, 1 to 6 months apart. The intra- and interlaboratory components of assay variance were isolated and compared by Bartlett's test for homogeneity of variance. Fluorescence polarization immunoassay (Abbott) showed the best overall intra- and interlaboratory performance for a range of analytes. The largest intralaboratory errors were produced by techniques using the Syva EMIT assays. Our analysis of the data shows that for most analyte/technique combinations, intralaboratory sources of variation were more important than interlaboratory sources. Gains in assay precision will therefore result from attention to internal laboratory procedures.

2018 ◽  
Vol 56 (11) ◽  
pp. 1921-1925 ◽  
Author(s):  
Diego Franciotta ◽  
Matteo Gastaldi ◽  
Tiziana Biagioli ◽  
Luana Benedetti ◽  
Claudia Giannotta ◽  
...  

Abstract Background Anti-ganglioside antibodies are currently used in the differential diagnosis of suspected immune-mediated neuropathies. In-house and increasingly used commercial assays seem to perform suboptimally, and comparative information on their analytical performance are essentially lacking. Born within the frame of guidelines and standardization activities by the Italian Association of Neuroimmunology, this external quality assessment scheme (EQAS) is a real-life snapshot of the laboratory diagnostics in this field. Methods The EQAS consisted of five surplus, anonymized serum samples from patients with clinically-defined neuropathies and two serum samples from healthy blood donors. Eight laboratories used commercial line-/dot-blots, seven in-house/commercial ELISAs (in addition, 13 laboratories tested a recently released ELISA by Bühlmann). Only high anti-ganglioside antibody reactivities were considered, in accordance with consolidated recommendations. Results Large variations in anti-ganglioside antibody profiles were observed, even, although to a lesser extent, within homogeneous classes of assays. Concordance between the profiles and clinical phenotypes was also partial. Conclusions Although conducted on a relatively small, but representative number of Italian laboratories, this EQAS shows a critical between-laboratory disagreement in the test results of anti-ganglioside antibodies. Also considering the trend for using certified assays in generalist laboratories, strong efforts toward standardization and the identification of the best method(s) for their determinations are compellingly needed.


2007 ◽  
Vol 53 (6) ◽  
pp. 1104-1108 ◽  
Author(s):  
Isolde Seiden-Long ◽  
Reinhold Vieth

Abstract Background: Radioactive reagents are used in most assays for measurement of 1,25-dihydroxyvitamin D [1,25(OH)2D]. We evaluated a 1,25(OH)2D enzyme immunoassay (EIA) from IDS Ltd. that uses solid-phase immunoextraction and colorimetric detection and compared results to those of the thymus radioreceptor assay (RRA) for 1,25(OH)2D. Methods: We collected serum samples (n = 145) representing an even distribution (0–200 pmol/L) of 1,25(OH)2D concentrations and Vitamin D External Quality Assessment Scheme (DEQAS) proficiency survey samples from 2004 surveys (n = 15) and stored them at −20 °C. We analyzed all samples with both EIA and RRA methods. We calculated imprecision using 5 QC samples in quadruplicate in each run (n = 6), including both pooled patient material used for QC with the RRA and QC material included in the EIA reagent set. We evaluated calibration stability by analyzing calibrators from different lots on the same plate and determining if calculated sample values drifted significantly. Results: Deming linear regression between IDS EIA and RRA methods yielded slope 1.25 (95% CI 1.13–1.37), y-intercept −3 (95% CI −18 to 12), R2 = 0.74. DEQAS proficiency survey samples for 2004 were all within 30% of the all-methods-trimmed mean. Imprecision CVs were 12%–16% within-run and 15%–20% between-run. Conclusions: We find no evidence of inferiority to the classic calf-thymus receptor assay for 1,25(OH)2D and no disadvantage in the results generated by the IDS EIA using samples from the major proficiency survey for 1,25(OH)2D. According to the product insert, however, the IDS EIA underestimates 1,25(OH)2D2 compared with the D3 form.


1992 ◽  
Vol 38 (4) ◽  
pp. 553-557 ◽  
Author(s):  
P J Pringle ◽  
J Jones ◽  
P C Hindmarsh ◽  
M A Preece ◽  
C G Brook

Abstract The immunoradiometric assay (IRMA) used in our laboratory for the measurement of growth hormone (hGH; somatotropin) performed badly in the national proficiency survey program, the U.K. External Quality Assessment Scheme (EQAS). We compared our assay with another IRMA, which gave similar results for patients' samples and performed adequately in EQAS. The samples from EQAS are collected from patients with polycythemia and fall into two categories: those containing endogenous hGH and those supplemented with pituitary-derived hGH. Analysis of the two groups separately showed that the differences between the two IRMAS were in the measurement of the endogenous hormone. The reason for this appears to be a matrix effect related to the fact that the EQAS serum samples are collected from polycythemic patients.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 5793-5793
Author(s):  
Vinod Devalia ◽  
Finlay Mackenzie

Background Although serum B12 assay is the most commonly used routine test for assessing cobalamin status in the body, it has its limitations (Mackenzie F and Devalia V (2018) Laboratory performance of serum B12 assay in the United Kingdom (UK) as assessed by the UK National External Quality Assessment Scheme for haematinics: implications for clinical interpretation. BLOOD, 132, suppl 1, 2230). Holotranscobalamin assay(HoloTC), also known as 'Active B12' assay, is an alternative test which is increasingly used as a first line test since it is felt to represent the assessment of the functional component of the cobalamin status of the body, and possibly a more relevant assessment clinically. However, its technical performance in terms of reliability and suitability in a routine diagnostic laboratory for clinical assessment has not been published. In the United Kingdom, there are over 30 laboratories performing the assay using five different platforms. The numerical value obtained of any sample can vary considerably between the different methodologies used.. External quality assessment of the assays is organised by UK NEQAS for Haematinics by sending three serum samples every 3 months. An 'all participants' consensus mean is calculated and used as the target value and the results analysed with respect to intra-group variation. The percentage bias from the target value is used to assess performance. Aim We present data on one such assessment to demonstrate the performance of the serum holotranscobalamin assay (Survey number 248, April 2018) and also how it is interpreted by the laboratory for clinical use. Method Three serum samples with a HoloTC target value of approximately 7.98 (low/indeterminate), 35.7 (normal/indeterminate) and 53.2 (normal) pmol/L were sent to participating laboratories for analysis (labelled as 248A, B and C respectively: see figure 1). Laboratories were also asked for an interpretation of their result which would be reported to the requesting clinician, namely from low to high (see figure 2). Results Fig 1 shows an individual laboratory's result in relation to all laboratories using the same technology (shaded histogram) or all methods (open histogram). There is a significant variation with an overall co-efficient of variation of around 10% within all the three different samples. Fig 2 shows the distribution of results in the different methodologies used and how each laboratory interpreted its result. It demonstrates the bias of results obtained by the different methods.The vast majority use the Abbot Architect (AB13) platform, and there is a suggestion of a trend of the results obtained to lie on the lower side than the other platforms used. For sample 248A, all laboratories reported it as 'low' or deficient. For sample 248B, there is a significant variation is reporting the sample as 'low', 'normal' or 'indeterminate' within the same platform used, clearly seen in the Abbot Architecture group. Indeed, the interpretation provided by the laboratory varies even with the same numerical value of the result. Discussion These data demonstrate that serum HoloTC assay has an overall co-efficient of variation around 10%. The numerical value obtained of any sample can vary considerably according to the technology used, and the clinical interpretation provided by the laboratory can be variable and not entirely concordant with the numerical result of the assay used. This is particularly evident around the 30-40 pmol/L range. This may be partly explained by the fact that it is not quite clear what would be regarded as the normal or reference range, which has been previously taken as 40 - 200 pmol/L (according to previous publications). Conclusion The UK NEQAS Haematinics Programme is unique in providing external quality assessment for laboratories using HoloTC assays for determining body cobalamin status in a style that is also unique across EQA/ PT schemes. Laboratories need to assess their performance in analysis of serum HoloTC levels in order to provide appropriate clinical advice. Ideally clinicians should be aware of the limitations of the HoloTC assay as demonstrated in this external quality assessment scheme exercise. Disclosures No relevant conflicts of interest to declare.


1994 ◽  
Vol 72 (03) ◽  
pp. 426-429 ◽  
Author(s):  
S Kitchen ◽  
I D Walker ◽  
T A L Woods ◽  
F E Preston

SummaryWhen the International Normalised Ratio (INR) is used for control of oral anticoagulant therapy the same result should be obtained irrespective of the laboratory reagent used. However, in the UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation INRs determined using different reagents have been significantly different.For 18 NEQAS samples Manchester Reagent (MR) was associated with significantly lower INRs than those obtained using Diagen Activated (DA, p = 0.0004) or Instrumentation Laboratory PT-Fib HS (IL, p = 0.0001). Mean INRs for this group were 3.15, 3.61, and 3.65 for MR, DA, and IL respectively. For 61 fresh samples from warfarin-ised patients with INRs of greater than 3.0 the relationship between thromboplastins in respect of INR was similar to that observed for NEQAS data. Thus INRs obtained with MR were significantly lower than with DA or IL (p <0.0001). Mean INRs for this group were 4.01, 4.40, and 4.59 for MR, DA, and IL respectively.We conclude that the differences between INRs measured with the thromboplastins studied here are sufficiently great to influence patient management through warfarin dosage schedules, particularly in the upper therapeutic range of INR. There is clearly a need to address the issues responsible for the observed discrepancies.


2007 ◽  
Vol 15 (2) ◽  
pp. 297-302 ◽  
Author(s):  
Olga Sánchez Negrette ◽  
Fernando J. Sánchez Valdéz ◽  
Carlos D. Lacunza ◽  
María Fernanda García Bustos ◽  
María Celia Mora ◽  
...  

ABSTRACT Serological tests are the main laboratory procedures used for diagnosis during the indeterminate and chronic stages of Chagas' disease. A serological regression to negativity is the main criterion used to define parasitological cure in treated patients. The aim of this work was to monitor the individual specificities of antibody levels for 3 years posttreatment in 18 adult patients. Conventional serological techniques (hemagglutination assays and enzyme-linked immunosorbent assay [ELISA]) were modified by using recombinant antigens to detect early markers of treatment effectiveness. For this purpose, serum samples were taken before and during treatment and every 6 months after treatment for at least 3 years. When hemagglutination assays were used, a decrease in antibody levels was observed in only one patient. When ELISA with serum dilutions was used, antibody clearance became much more apparent: in 77.7% (14/18) of the patients, antibody titers became negative with time. This was observed at serum dilutions of 1/320 and occurred between the 6th and the 30th months posttreatment. The immune response and the interval for a serological regression to negativity were different for each patient. For some of the recombinant antigens, only 50% (9/18) of the patients reached the serological regression to negativity. Recombinant antigen 13 might be a good marker of treatment effectiveness, since 66.6% (six of nine) of the patients presented with an early regression to negativity for specific antibodies to this antigen (P = 0.002).


2020 ◽  
Vol 55 (4) ◽  
pp. 271-276
Author(s):  
Ewa Młodzińska ◽  
Waleria Hryniewicz

The increase in bacterial resistance to antimicrobials is one of the most serious medical problems, therefore reliable identification in microbiological laboratories is important. The Polish National External Quality Assessment Scheme in Microbiological Diagnostics – POLMICRO programme is organized by the Centre of Quality Control in Microbiology (CQCM) enables the assessment of the competence of Polish microbiological laboratories in the field of identification, determination of susceptibility and detection of drug resistance mechanisms. This work presents the assessment of the results of identification and determination of S. pneumoniae antimicrobial susceptibility obtained by Polish laboratories during the 20 years of experience of the POLMICRO programme.