scholarly journals Single-Laboratory Validation of the Biosense Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA) for Determination of Domoic Acid Toxins in Shellfish

2007 ◽  
Vol 90 (4) ◽  
pp. 1000-1010 ◽  
Author(s):  
Hans Kleivdal ◽  
Sven-Inge Kristiansen ◽  
Mona V Nilsen ◽  
Lyn Briggs

Abstract Method validation was conducted for an enzyme-linked immunosorbent assay (ELISA) for the determination of domoic acid (DA) toxins, known to give amnesic shellfish poisoning (ASP) symptoms, in shellfish. The calibration curve range of the assay is approximately 10260 pg/mL, with a dynamic working range for DA toxins in shellfish from 0.01 to at least 250 mg/kg. The ASP ELISA showed no significant cross-reactivity to structural analogs, and proved to be robust to deliberate alterations of the optimal running conditions. The shellfish matrix effects observed with mussels, oysters, and scallops were eliminated by diluting shellfish extracts 1:200 prior to analysis, leading to a limit of detection at 0.003 mg/kg. Thirteen blank shellfish homogenates were spiked with certified mussel material containing DA to levels in the range of 0.125 mg DA/kg, and analyzed in quadruplicate on 3 different days. The relative standard deviation (RSD) under intra-assay repeatability conditions ranged from 6.5 to 13.1%, and under interassay repeatability conditions the RSD ranged from 5.7 to 13.4%, with a mean value of 9.3%. The recoveries ranged from 85.5 to 106.6%, with a mean recovery of 102.2%. A method comparison was conducted with liquid chromatography with ultraviolet detection, using naturally contaminated scallop samples (n = 27) with DA levels at 0244 mg/kg. The overall correlation coefficient was 0.960 and the slope of the regression was 1.218, indicating a good agreement between the methods.

1995 ◽  
Vol 78 (6) ◽  
pp. 1403-1407 ◽  
Author(s):  
Eoin P Carmody ◽  
Kevin J James ◽  
Seán S Kelly

Abstract Dinophysistoxin-2 (DTX-2), an isomer of okadaic acid (OA), recently has been found in Irish waters. DTX-2 was the predominant toxin during prolonged infestations in cultivated mussels along the southwest coast of Ireland. Substantial variations in toxin levels may exist both horizontally and vertically in the water column. The need to take multiple samples and the ethical concern about the use of mammals for routine quality control of shellfish prompted examination of 2 commercially available enzyme-linked immunosorbent assay (ELISA) methods, designed to detect OA, for determination of both OA and DTX-2. One ELISA method (DSPCheck, Sceti Co. Ltd., (Tokyo, Japan) showed good cross-reactivity (40 ± 5%) with standard DTX-2. This study showed that both ELISA methods show good correlation with the liquid chromatographic analysis of 9-anthryldiazomethane derivatives when OA is the predominant toxin present. The sensitivity was also good for OA determination using both methods, which allowed toxin measurement at 10 ng/mL (0.5 ng/well). This level is equivalent to 0.03 μg/g mussel meat. Blank mussel samples spiked with DTX-2 standards gave a good linear correlation (r = 0.997) with this ELISA method when toxin levels were 0.03-0.3 μg/g mussel meat. This range is appropriate for regulatory control of diarrhetic shellfish poisoning.


2007 ◽  
Vol 90 (4) ◽  
pp. 1011-1027 ◽  
Author(s):  
Hans Kleivdal ◽  
Sven-Inge Kristiansen ◽  
Mona V Nilsen ◽  
Anders Goksyr ◽  
Lyn Briggs ◽  
...  

Abstract A collaborative study was conducted on the Biosense amnesic shellfish poisoning (ASP) enzyme-linked immunosorbent assay (ELISA) for the determination of domoic acid (DA) toxins in shellfish in order to obtain interlaboratory validation data for the method. In addition, a method comparison study was performed to evaluate the ASP ELISA as an alternative to the current liquid chromatography (LC) reference method for DA determination. The study material comprised 16 shellfish samples, including blue mussels, Pacific oysters, and king scallops, spiked with contaminated mussel homogenates to contain 0.120 mg DA/kg shellfish flesh. The shellfish samples were extracted with 50% aqueous methanol, and the supernatants were directly analyzed. Sixteen participating laboratories in 10 countries reported data from the ASP ELISA, and 4 of these laboratories also reported data from instrumental LC analysis. The participating laboratories achieved interlaboratory precision estimates for the 8 Youden paired shellfish samples in the range of 1020% for RSDr (mean 14.8 4%), and 1329% for RSDR (mean 22.7 6%). The precision estimates for the ELISA data did not show a strong dependence on the DA concentration in the study samples, and the overall precision achieved was within the acceptable range of the Horwitz guideline with HorRat values ranging from 1.1 to 2.4 (mean HorRat 1.7 0.5). The analysis of shellfish samples spiked with certified reference material (CRM)-ASP-MUS-b gave recoveries in the range of 88122%, with an average recovery of 104 10%. The estimate on method accuracy was supported by a correlation slope of 1.015 (R2 = 0.992) for the determined versus the expected DA values. Furthermore, the correlation of the ASP ELISA results with those for the instrumental LC analyses of the same sample extracts gave a correlation slope of 1.29 (R2 = 0.984). This indicates some overestimation of DA levels in shellfish by the ELISA, but it is also a result of apparent low recoveries for the LC methods. This interlaboratory study demonstrates that the ASP ELISA is suitable for the routine determination and monitoring of DA toxins in shellfish, and that it offers a rapid and cost-effective methodology with high sample throughput.


2008 ◽  
Vol 91 (1) ◽  
pp. 123-129 ◽  
Author(s):  
Shinobu Sakai ◽  
Rieko Matsuda ◽  
Reiko Adachi ◽  
Hiroshi Akiyama ◽  
Tamio Maitani ◽  
...  

Abstract The labeling of foods containing material derived from crustaceans such as shrimp and crab is to become mandatory in Japan because of increases in the number of allergy patients. To ensure proper labeling, 2 novel sandwich enzyme-linked immunosorbent assay (ELISA) kits for the determination of crustacean protein in processed foods, the N kit (Nissui Pharmaceutical Co., Ltd, Ibaraki, Japan) and the M kit (Maruha Nichiro Holdings, Inc., Ibaraki, Japan), have been developed. Five types of model processed foods containing 10 and/or 11.9 g/g crustacean soluble protein were prepared for interlaboratory evaluation of the performance of these kits. The N kit displayed a relatively high level of reproducibility relative standard deviation (interlaboratory precision; 4.08.4 RSDR) and sufficient recovery (6586) for all the model processed foods. The M kit displayed sufficient reproducibility (17.620.5 RSDR) and a reasonably high level of recovery (82103). The repeatability relative standard deviation (RSDr) values regarding the detection of crustacean proteins in the 5 model foods were mostly <5.1 RSDr for the N kit and 9.9 RSDr for the M kit. In conclusion, the results of this interlaboratory evaluation suggest that both these ELISA kits would be very useful for detecting crustacean protein in processed foods.


2004 ◽  
Vol 52 (17) ◽  
pp. 5334-5339 ◽  
Author(s):  
Feng-Yih Yu ◽  
Biing-Hui Liu ◽  
Ting-Shuan Wu ◽  
Tsuen-Feng Chi ◽  
Mao-Chang Su

1992 ◽  
Vol 75 (4) ◽  
pp. 693-697 ◽  
Author(s):  
Alan L Patey ◽  
Matthew Sharman ◽  
John Gilbert

Abstract Laboratories in Australia, Japan, Spain, the United Kingdom, and the United States participated in a collaborative study to evaluate a commercial enzyme- linked immunosorbent assay for the determination of total aflatoxin. Collaborators were sent 10 randomly numbered samples (5 blind duplicates) of roasted peanut butter. Two pairs were "blank" peanut butters to which aflatoxin B1, B2, G1, and G2 standards had been added. The other 3 pairs of peanut butters were 1 low aflatoxin level sample and 2 naturally contaminated samples. The assay is based on indirect competition. Test samples containing (free) aflatoxin, added to aflatoxin-coated microwells, compete for specific monoclonal rat anti-aflatoxin. As the concentration of aflatoxin in the test samples increases, the amount of rat antiaflatoxin binding to the aflatoxin attached to the well decreases. After a wash step to remove unbound material, the amount of rat anti-aflatoxin bound to the well is determined by its reaction with peroxidase conjugated rabbit anti-rat globulin. Bound peroxidase activity is then determined by the addition of a substrate, whose color development is inversely proportional to the aflatoxin concentration and is measured by absorbance. Coefficients of variation (CV) for total aflatoxin concentrations, for mean levels of 9,30, and 89µg/kg, were between 28 and 37% for the low level and 2 naturally contaminated samples, which contained mainly aflatoxin B1. CVs for the spiked samples were lower (24-25%) for mean levels of 11 and 20 µg/kg; recoveries were 84 and 89%, respectively. Ranges for relative standard deviations for repeatabilty and reproducibility were 9-30% and 25-37%, respectively. The method has been adopted first action by AOAC International.


Planta Medica ◽  
2018 ◽  
Vol 84 (14) ◽  
pp. 1038-1044 ◽  
Author(s):  
Benyakan Pongkitwitoon ◽  
Seiichi Sakamoto ◽  
Rika Nagamitsu ◽  
Waraporn Putalun ◽  
Hiroyuki Tanaka ◽  
...  

AbstractHomoharringtonine (HHT), also known as omacetaxine, is a natural compound found in the genus Cephalotaxus and is a promising pharmaceutical drug used for the treatment of chronic or accelerated phase chronic myeloid leukemia. As a tool for the quantitative determination of HHT, a specific monoclonal antibody against HHT (MAb 6A1) was generated by conjugates prepared via sodium periodate-mediated oxidation. The developed indirect competitive enzyme-linked immunosorbent assay (icELISA) using MAb 6A1 was found to be highly specific and sensitive with a limit of detection for HHT of 48.8 ng/mL. Validation assays to evaluate precision and accuracy of the method were conducted by the use of intra- and inter-assay analysis, recovery test, and comparison analysis between the amounts of HHT determined by ELISA and high-performance liquid chromatography. These results revealed that the established icELISA using MAb 6A1 is specific, sensitive, and reliable enough to be applied to the qualitative analysis for HHT. Furthermore, the results of this study support the usefulness of sodium periodate as a reagent for the conjugation between Cephalotaxus alkaloids and proteins for producing specific antibodies.


2001 ◽  
Vol 84 (6) ◽  
pp. 1891-1902 ◽  
Author(s):  
Mary W Trucksess ◽  
T Artis ◽  
C Diaz ◽  
C Fernandez ◽  
K Harkin ◽  
...  

Abstract The performance of a commercially available enzyme-linked immunosorbent assay kit (Enviro-Logix) was assessed for the determination of Cry9C protein, which is produced by the genetically modified corn StarLink, in 8 types of corn-based foods (starch, refined oil, soft tortillas, tortilla chips, corn flakes, corn puffs, corn muffins, and corn bread) in an interlaboratory study involving 7 laboratories in the United States. The assay kit is a double antibody sandwich and is based on the specific interaction between antibody and antigen. The Cry9C protein analyte is sandwiched between 2 antibodies, one to capture the analyte and the other is conjugated to the enzyme, horseradish peroxidase. The enzyme uses tetramethylbenzidine/peroxide for color development. A strong acid stopping reagent is then used to change the color from blue to a stable yellow. The intensity of the color is proportional to the concentration of the Cry9C protein. In this study blind duplicates of control samples (blank material prepared from non- StarLink corn), spiked samples (blank material with the addition of Cry9C protein), and samples containing incurred analyte (products prepared with StarLink corn) were analyzed. Cry9C protein from 2 different sources was used to spike the food products. Cry9C protein produced and purified from a bacterial host was used to prepare spiked test samples at 2.72 and 6.8 ng/g. Cry9C protein from StarLink corn flour was used to prepare spiked samples at 1.97 ng/g. Average recoveries for samples spiked with corn flour Cry9C protein at 1.97 ng/g ranged from 73 to 122%, within-laboratory relative standard deviations (RSDr) ranged from 6 to 22%, and between-laboratories relative standard deviations (RSDR) ranged from 16 to 56%. Average recoveries for samples spiked with bacterial Cry9C protein at 2.72 and 6.8 ng/g ranged from 27 to 96% and from 32 to 113%, respectively; RSDr values ranged from 10 to 35%and from 7 to 38%, respectively; and the RSDR ranged from 28 to 84%and 15 to 75%, respectively. The incurred test samples were found to contain Cry9C protein at levels ranging from 0.8 to 3187 ng/g depending on the product, RSDr values ranged from 5 to 16% and RSDR values ranged from 11 to 71%. Results of the statistical analysis indicate that this method is applicable to the determination of Cry9C protein in the 8 types of collaboratively studied corn-based products containing Cry9C protein (from StarLink ) at levels of ≥2 ng/g.


2011 ◽  
Vol 11 (1) ◽  
pp. 55-60 ◽  
Author(s):  
J. Zheng ◽  
S. Q. Zhao ◽  
X. T. Xu ◽  
K. Zhang

In order to study whether bisphenol A (BPA) can pass into drinking water from polycarbonate barrel and exist in the river and industrial effluent the indirect competitive enzyme-linked immunosorbent assay (ELISA) for the determination of BPA was established. The results presented an inhibition concentration at 50% absorbance (IC50) of 0.123 mg L−1, and the limit of detection (LOD) is 9.934 μg L−1. The specificity of antiserum was proved well because the cross-reactivity with benzene, tert-butylbenzene, hydroquinone and o-hydroxybenzoic acid were found lower than 0.01%, except phenol was 0.26%. The method was found to be reliable and repeatable. It was used for monitoring the concentration of BPA in the barreled drinking water. The results confirmed BPA can pass into barreled drinking water from the polycarbonate barrel and concentration increased as days went on. A certain content of BPA was found in industrial effluent. The results of ELISA were consistent with the results of UV spectrophotometry. BPA could not be found in the water samples obtained from Zhujiang River. The established method shows specific recognition of BPA and could be applied in detection of environmental BPA.


2015 ◽  
Vol 78 (2) ◽  
pp. 362-369 ◽  
Author(s):  
MINGYAN LIANG ◽  
TINGTING ZHANG ◽  
XUELAN LIU ◽  
YANAN FAN ◽  
SHENGLIN XIA ◽  
...  

Staphylococcal food poisoning (SFP), one of the most common foodborne diseases, results from ingestion of staphylococcal enterotoxins (SEs) in foods. In our previous studies, we found that SEA and SEG were two predominant SE proteins produced by milk-acquired S. aureus isolates. Here, a tandemly arranged multiepitope peptide (named SEAGepis) was designed with six linear B-cell epitopes derived from SEA or SEG and was heterologously expressed. The SEAGepis-specific antibody was prepared by immunizing rabbit with rSEAGepis. Then, an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) based on rSEAGepis and the corresponding antibody was developed to simultaneously detect SEA and SEG. Under the optimized conditions, the ic-ELISA standard curve for rSEAGepis was constructed in the concentration range of 0.5 to 512 ng/ml, and the average coefficients of variation of intra-and interassay were 4.28 and 5.61% during six standard concentrations. The average half-maximal inhibitory concentration was 5.07 ng/ml, and the limit of detection at a signal-to-noise ratio of 3 was 0.52 ng/ml. The anti-rSEAGepis antibody displayed over 90% cross-reactivity with SEA and SEG but less than 0.5% cross-reactivity with other enterotoxins. Artificially contaminated milk with different concentrations of rSEAGepis, SEA, and SEG was detected by the established ic-ELISA; the recoveries of rSEAGepis, SEA, and SEG were 91.1 to 157.5%, 90.3 to 134.5%, and 89.1 to 117.5%, respectively, with a coefficient of variation below 12%. These results demonstrated that the newly established ic-ELISA possessed high sensitivity, specificity, stability, and accuracy and could potentially be a useful analytical method for synchronous detection of SEA and SEG in milk.


1997 ◽  
Vol 78 (04) ◽  
pp. 1262-1267 ◽  
Author(s):  
Claudia C Folman ◽  
Albert E G K von dem Borne ◽  
Irma H J A M Rensink ◽  
Winald Gerritsen ◽  
C Ellen van der Schoot ◽  
...  

SummaryIn this report a sensitive enzyme-linked immunosorbent assay (ELISA) for the measurement of plasma thrombopoietin (Tpo) is described that is solely based on monoclonal antibodies (MoAbs).The assay has an intra and inter-assay variance of 5-7% and 7-13%, respectively. Native and recombinant human Tpo (rhTpo) were recognized equally well, no cross reactivity with other cytokines was found and rhTpo added to plasma and serum was completely recovered. With the ELISA, Tpo concentrations in EDTA-anticoagulated plasma of all controls (n = 193) could be determined, since the limit of detection (2 ± 0.8 A.U./ml, mean ± sd) was lower than the concentration found in controls (11 ± 8 A.U./ml, mean ± sd; 2.5th-97.5th percentile: 4-32 A.U./ml). Tpo levels in serum were on average 3.4 times higher than in plasma.We showed in vivo that Tpo is bound by platelets, as in thrombocytopenic patients (n = 5) a platelet transfusion immediately led to a drop in plasma Tpo level, whereas in patients receiving chemotherapy the induced thrombocytopenia was followed by a rise in plasma Tpo levels.In summary, these results indicate that this ELISA is a reliable tool for Tpo measurements and is applicable for large scale studies.


Sign in / Sign up

Export Citation Format

Share Document