Determination of ethyl glucuronide and ethyl sulfate in human whole blood and vitreous humor by LC-MS/MS and applications to the interpretation of postmortem ethanol findings

Author(s):  
Hao Wang ◽  
Beixu Li ◽  
Fanglin Wang ◽  
Jing Chang ◽  
Yunfeng Zhang ◽  
...  

Abstract Identifying the source of ethanol in a decedent remained a complicated problem for forensic toxicologists because of postmortem ethanol formation. As ethanol’s non-oxidative metabolites, ethyl glucuronide (EtG) and ethyl sulfate (EtS) have the potential to distinguish between antemortem ethanol consumption and postmortem ethanol formation, due to their high sensitivity and selectivity. In the current study, a simple and quick liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the determination of EtG and EtS in human whole blood and vitreous humor (VH). A total of 20 μL of the sample was precipitated by methanol, and the analytes were detected by LC-MS/MS in a run of 6 min. This method achieved high sensitivity (limits of detection: 2 ng/mL for both EtG and EtS), with linearity in the range of 5–10,000 ng/mL in both whole blood and VH. Deviations in accuracy, inter- and intra-day precision were all lower than 15% at three quality control levels. Subsequently, this method was applied to 62 real forensic cases. Only blood samples were available in 52 cases. Paired blood and VH samples were present in 10 cases. The concentrations of EtG and EtS in blood were in the range of 0–22,264.8 ng/mL and 0–2,126.0 ng/mL, respectively. In one case with both blood and VH, the blood ethanol concentration was 1.22 mg/mL, with EtG and EtS both below limits of quantification (5 ng/mL) in VH, and no EtG and EtS found in whole blood. The results suggested that EtG and EtS were useful markers for the interpretation of ethanol resource in postmortem blood and VH.

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Quang Hieu Tran ◽  
Thanh Tan Nguyen ◽  
Kim Phuong Pham

A selective, sensitive, and rapid method by using ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the determination of histamine in fish and fish sauce was developed. The optimal conditions of liquid chromatographic separation and mass spectroscopy of histamine have also been investigated. The linear ranges of the method were 20.0 ÷ 1000 ng/mL, and the corresponding correlation coefficient was 0.9993. Mean recoveries of the analyte at three spike levels (low, medium, and high) were within the range of 98.5% ÷ 102.5% (n = 7). The limit of detection (LOD) and limit of quantification (LOQ) values were 3.83 and 11.50 ng/mL for the fish sauce sample and 4.71 and 14.12 ng/mL for the fish sample, respectively. The influence of the matrix effect on the accuracy, repeatability, and recovery of the method was negligible. The recommended method was applied to determine the content of this substance in 21 fish sauce samples and 4 kinds of fish samples, which were collected from Ho Chi Minh City, Vietnam, in 2019.


Methods ◽  
2006 ◽  
Vol 38 (2) ◽  
pp. 77-83 ◽  
Author(s):  
Tanja Breinig ◽  
Martina Sester ◽  
Urban Sester ◽  
Andreas Meyerhans

2007 ◽  
Vol 66 (9-10) ◽  
pp. 735-739 ◽  
Author(s):  
Qing Xu ◽  
Mei Huang ◽  
Micong Jin ◽  
Qilong Ren

2013 ◽  
Vol 58 (2) ◽  
pp. 1733-1736 ◽  
Author(s):  
FELIPE BRAVO ◽  
CARMEN ZAMBRA ◽  
KARINA VENEGAS ◽  
DAVID RIOS ◽  
PEDRO BUC CALDERON ◽  
...  

2020 ◽  
Vol 7 (12) ◽  
pp. 201500
Author(s):  
Sha Liu ◽  
Yong Li ◽  
Chao Yang ◽  
Liqiang Lu ◽  
Yulun Nie ◽  
...  

Arsenic contamination in groundwater is a supreme environmental problem, and levels of this toxic metalloid must be strictly monitored by a portable, sensitive and selective analytical device. Herein, a new system of smartphone-integrated paper sensors with Cu nanoclusters was established for the effective detection of As(III) in groundwater. For the integration system, the fluorescence emissive peak of Cu nanoclusters at 600 nm decreased gradually with increasing As(III) addition. Meanwhile, the fluorescence colour also changed from orange to colourless, and the detection limit was determined as 2.93 nM (0.22 ppb) in a wide detection range. The interfering ions also cannot influence the detection selectivity of As(III). Furthermore, the portable paper sensors based on Cu nanoclusters were fabricated for visual detection of As(III) in groundwater. The quantitative determination of As(III) in natural groundwater has also been accomplished with the aid of a common smartphone. Our work has provided a portable and on-site detection technique toward As(III) in groundwater with high sensitivity and selectivity.


Sign in / Sign up

Export Citation Format

Share Document