scholarly journals Kinetic Analysis of the 5-HT2A Ligand [11C]MDL 100,907

2000 ◽  
Vol 20 (6) ◽  
pp. 899-909 ◽  
Author(s):  
Hiroshi Watabe ◽  
Michael A. Channing ◽  
Margaret G. Der ◽  
H. Richard Adams ◽  
Elaine Jagoda ◽  
...  

The goal of this study was to develop a suitable kinetic analysis method for quantification of 5-HT2A receptor parameters with [11C]MDL 100,907. Twelve control studies and four preblocking studies (400 nmol/kg unlabeled MDL 100,907) were performed in isoflurane-anesthetized rhesus monkeys. The plasma input function was determined from arterial blood samples with metabolite measurements by extraction in ethyl acetate. The preblocking studies showed that a two-tissue compartment model was necessary to fit the time activity curves of all brain regions including the cerebellum—in other words, the need for two compartments is not proof of specific binding. Therefore, a three-tissue compartment model was used to analyze the control studies, with three parameters fixed based on the preblocking data. Reliable fits of control data could be obtained only if no more than three parameters were allowed to vary. For routine use of [11C]MDL 100,907, several simplified methods were evaluated. A two-tissue (2T‘) compartment with one fixed parameter was the most reliable compartmental approach; a one-compartment model failed to fit the data adequately. The Logan graphical approach was also tested and produced comparable results to the 2T’ model. However, a simulation study showed that Logan analysis produced a larger bias at higher noise levels. Thus, the 2T' model is the best choice for analysis of [11C]MDL 100,907 studies.

2019 ◽  
Vol 47 (2) ◽  
pp. 379-389 ◽  
Author(s):  
Marloes H. J. Hagens ◽  
Sandeep S. V. Golla ◽  
Bieneke Janssen ◽  
Danielle J. Vugts ◽  
Wissam Beaino ◽  
...  

Abstract Purpose The novel PET tracer [11C]SMW139 binds with high affinity to the P2X7 receptor, which is expressed on pro-inflammatory microglia. The purposes of this first in-man study were to characterise pharmacokinetics of [11C]SMW139 in patients with active relapsing remitting multiple sclerosis (RRMS) and healthy controls (HC) and to evaluate its potential to identify in vivo neuroinflammation in RRMS. Methods Five RRMS patients and 5 age-matched HC underwent 90-min dynamic [11C]SMW139 PET scans, with online continuous and manual arterial sampling to generate a metabolite-corrected arterial plasma input function. Tissue time activity curves were fitted to single- and two-tissue compartment models, and the model that provided the best fits was determined using the Akaike information criterion. Results The optimal model for describing [11C]SMW139 kinetics in both RRMS and HC was a reversible two-tissue compartment model with blood volume parameter and with the dissociation rate k4 fixed to the whole-brain value. Exploratory group level comparisons demonstrated an increased volume of distribution (VT) and binding potential (BPND) in RRMS compared with HC in normal appearing brain regions. BPND in MS lesions was decreased compared with non-lesional white matter, and a further decrease was observed in gadolinium-enhancing lesions. In contrast, increased VT was observed in enhancing lesions, possibly resulting from disruption of the blood-brain barrier in active MS lesions. In addition, there was a high correlation between parameters obtained from 60- to 90-min datasets, although analyses using 60-min data led to a slight underestimation in regional VT and BPND values. Conclusions This first in-man study demonstrated that uptake of [11C]SMW139 can be quantified with PET using BPND as a measure for specific binding in healthy controls and RRMS patients. Additional studies are warranted for further clinical evaluation of this novel neuroinflammation tracer.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sébastien Goutal ◽  
Martine Guillermier ◽  
Guillaume Becker ◽  
Mylène Gaudin ◽  
Yann Bramoullé ◽  
...  

Abstract Background Positron Emission Tomography (PET) imaging of the Synaptic Vesicle glycoprotein (SV) 2A is a new tool to quantify synaptic density. [18F]UCB-H was one of the first promising SV2A-ligands to be labelled and used in vivo in rodent and human, while limited information on its pharmacokinetic properties is available in the non-human primate. Here, we evaluate the reliability of the three most commonly used modelling approaches for [18F]UCB-H in the non-human cynomolgus primate, adding the coupled fit of the non-displaceable distribution volume (VND) as an alternative approach to improve unstable fit. The results are discussed in the light of the current state of SV2A PET ligands. Results [18F]UCB-H pharmacokinetic data was optimally fitted with a two-compartment model (2TCM), although the model did not always converge (large total volume of distribution (VT) or large uncertainty of the estimate). 2TCM with coupled fit K1/k2 across brain regions stabilized the quantification, and confirmed a lower specific signal of [18F]UCB-H compared to the newest SV2A-ligands. However, the measures of VND and the influx parameter (K1) are similar to what has been reported for other SV2A ligands. These data were reinforced by displacement studies using [19F]UCB-H, demonstrating only 50% displacement of the total [18F]UCB-H signal at maximal occupancy of SV2A. As previously demonstrated in clinical studies, the graphical method of Logan provided a more robust estimate of VT with only a small bias compared to 2TCM. Conclusions Modeling issues with a 2TCM due to a slow component have previously been reported for other SV2A ligands with low specific binding, or after blocking of specific binding. As all SV2A ligands share chemical structural similarities, we hypothesize that this slow binding component is common for all SV2A ligands, but only hampers quantification when specific binding is low.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Mercy I. Akerele ◽  
Sara A. Zein ◽  
Sneha Pandya ◽  
Anastasia Nikolopoulou ◽  
Susan A. Gauthier ◽  
...  

Abstract Introduction Quantitative positron emission tomography (PET) studies of neurodegenerative diseases typically require the measurement of arterial input functions (AIF), an invasive and risky procedure. This study aims to assess the reproducibility of [11C]DPA-713 PET kinetic analysis using population-based input function (PBIF). The final goal is to possibly eliminate the need for AIF. Materials and methods Eighteen subjects including six healthy volunteers (HV) and twelve Parkinson disease (PD) subjects from two [11C]-DPA-713 PET studies were included. Each subject underwent 90 min of dynamic PET imaging. Five healthy volunteers underwent a test-retest scan within the same day to assess the repeatability of the kinetic parameters. Kinetic modeling was carried out using the Logan total volume of distribution (VT) model. For each data set, kinetic analysis was performed using a patient-specific AIF (PSAIF, ground-truth standard) and then repeated using the PBIF. PBIF was generated using the leave-one-out method for each subject from the remaining 17 subjects and after normalizing the PSAIFs by 3 techniques: (a) Weightsubject×DoseInjected, (b) area under AIF curve (AUC), and (c) Weightsubject×AUC. The variability in the VT measured with PSAIF, in the test-retest study, was determined for selected brain regions (white matter, cerebellum, thalamus, caudate, putamen, pallidum, brainstem, hippocampus, and amygdala) using the Bland-Altman analysis and for each of the 3 normalization techniques. Similarly, for all subjects, the variabilities due to the use of PBIF were assessed. Results Bland-Altman analysis showed systematic bias between test and retest studies. The corresponding mean bias and 95% limits of agreement (LOA) for the studied brain regions were 30% and ± 70%. Comparing PBIF- and PSAIF-based VT estimate for all subjects and all brain regions, a significant difference between the results generated by the three normalization techniques existed for all brain structures except for the brainstem (P-value = 0.095). The mean % difference and 95% LOA is −10% and ±45% for Weightsubject×DoseInjected; +8% and ±50% for AUC; and +2% and ± 38% for Weightsubject×AUC. In all cases, normalizing by Weightsubject×AUC yielded the smallest % bias and variability (% bias = ±2%; LOA = ±38% for all brain regions). Estimating the reproducibility of PBIF-kinetics to PSAIF based on disease groups (HV/PD) and genotype (MAB/HAB), the average VT values for all regions obtained from PBIF is insignificantly higher than PSAIF (%difference = 4.53%, P-value = 0.73 for HAB; and %difference = 0.73%, P-value = 0.96 for MAB). PBIF also tends to overestimate the difference between PD and HV for HAB (% difference = 32.33% versus 13.28%) and underestimate it in MAB (%difference = 6.84% versus 20.92%). Conclusions PSAIF kinetic results are reproducible with PBIF, with variability in VT within that obtained for the test-retest studies. Therefore, VT assessed using PBIF-based kinetic modeling is clinically feasible and can be an alternative to PSAIF.


Molecules ◽  
2019 ◽  
Vol 24 (22) ◽  
pp. 4094 ◽  
Author(s):  
Lars Jødal ◽  
Anne Roivainen ◽  
Vesa Oikonen ◽  
Sirpa Jalkanen ◽  
Søren B. Hansen ◽  
...  

Background: [68Ga]Ga-DOTA-Siglec-9 is a positron emission tomography (PET) radioligand for vascular adhesion protein 1 (VAP-1), a protein involved in leukocyte trafficking. The tracer facilitates the imaging of inflammation and infection. Here, we studied the pharmacokinetic modelling of [68Ga]Ga-DOTA-Siglec-9 in osteomyelitis and soft tissue infections in pigs. Methods: Eight pigs with osteomyelitis and soft tissue infections in the right hind limb were dynamically PET scanned for 60 min along with arterial blood sampling. The fraction of radioactivity in the blood accounted for by the parent tracer was evaluated with radio-high-performance liquid chromatography. One- and two-tissue compartment models were used for pharmacokinetic evaluation. Post-mortem soft tissue samples from one pig were analysed with anti-VAP-1 immunofluorescence. In each analysis, the animal’s non-infected left hind limb was used as a control. Results: Tracer uptake was elevated in soft tissue infections but remained low in osteomyelitis. The kinetics of [68Ga]Ga-DOTA-Siglec-9 followed a reversible 2-tissue compartment model. The tracer metabolized quickly; however, taking this into account, produced more ambiguous results. Infected soft tissue samples showed endothelial cell surface expression of the Siglec-9 receptor VAP-1. Conclusion: The kinetics of [68Ga]Ga-DOTA-Siglec-9 uptake in porcine soft tissue infections are best described by the 2-tissue compartment model.


2020 ◽  
pp. 0271678X2092814 ◽  
Author(s):  
Ayla Mansur ◽  
Eugenii A Rabiner ◽  
Hideo Tsukada ◽  
Robert A Comley ◽  
Yvonne Lewis ◽  
...  

Mitochondrial complex I (MC-I) is an essential regulator of brain bioenergetics and can be quantified in the brain using PET radioligand 18F-BCPP-EF. Here we evaluate the test–retest reproducibility of 18F-BCPP-EF in humans, and assess the use of a non-invasive quantification method (standardised uptake value ratio – SUVR). Thirty healthy volunteers had a 90-min dynamic 18F-BCPP-EF scan with arterial blood sampling, five of which received a second scan to be included in the test–retest analysis. Time-activity curves (TAC) were analysed using multilinear analysis 1 (MA1) and the two-tissue compartment model (2TC) to estimate volumes of distribution (VT). Regional SUVR-1 values were calculated from the 70 to 90-min TAC data using the centrum semiovale as a pseudo reference region, and compared to kinetic analysis-derived outcome measures. The mean absolute test–retest variability of VT ranged from 12% to 18% across regions. Both DVR-1and SUVR-1 had improved test–retest variability in the range 2%–7%. SUVR-1 was highly correlated with DVR-1 (r2 = 0.97, n = 30). In conclusion, 18F-BCPP-EF has suitable test–retest reproducibility and can be used to quantify MC-I in clinical studies.


1988 ◽  
Vol 255 (1) ◽  
pp. E94-E98 ◽  
Author(s):  
S. L. Lehman ◽  
W. C. Stanley

When a substrate appears in and disappears from an unmeasured (tissue) compartment, the proper sites for tracer infusion and sampling to measure tracee turnover become controversial. We analyze a three-compartment model representing arterial blood, tissue, and venous blood. The desired quantity, tracee turnover, is the ratio of the steady-state infusion rate to tissue specific activity. However, specific activity in the tissue compartment is unknown. We assume infusion of tracer into the arterial pool at a constant rate and consider sampling of specific activity of either blood compartment in the steady state. We obtain estimates of tissue specific activity from measurement of concentrations of tracer and tracee in blood samples in two extreme cases. In case I, tracee is assumed to appear in the venous compartment but to disappear from the tissue pool. Then tissue specific activity is equal to arterial specific activity. In case II, both appearance and disappearance are from the tissue pool. Tissue specific activity is then less than arterial or venous specific activity. We give formulas for the difference in each case. We discuss the relationship of our models to actual tracer experiments and define physiological locations for our three compartments. Appearance of substrates is probably intermediate between our extreme cases. A numerical estimate of turnover for the substrate lactate in resting humans reveals an error bound of approximately 30%. We discuss sites of infusion and sampling consistent with our model, the effects of relaxing some of our modeling constraints, and experimental necessities for getting beyond the steady state.


2001 ◽  
Vol 21 (11) ◽  
pp. 1354-1366 ◽  
Author(s):  
Shin-Ichiro Nagatsuka ◽  
Kiyoshi Fukushi ◽  
Hitoshi Shinotoh ◽  
Hiroki Namba ◽  
Masaomi Iyo ◽  
...  

N-[11C]methylpiperidin-4-yl acetate ([11C]MP4A) is an acetylcholine analog. It has been used successfully for the quantitative measurement of acetylcholinesterase (AChE) activity in the human brain with positron emission tomography (PET). [11C]MP4A is specifically hydrolyzed by AChE in the brain to a hydrophilic metabolite, which is irreversibly trapped locally in the brain. The authors propose a new method of kinetic analysis of brain AChE activity by PET without arterial blood sampling, that is, reference tissue-based linear least squares (RLS) analysis. In this method, cerebellum or striatum is used as a reference tissue. These regions, because of their high AChE activity, act as a biologic integrator of plasma input function during PET scanning, when regional metabolic rates of [11C]MP4A through AChE (k3; an AChE index) are calculated by using Blomqvist's linear least squares analysis. Computer simulation studies showed that RLS analysis yielded k3 with almost the same accuracy as the standard nonlinear least squares (NLS) analysis in brain regions with low (such as neocortex and hippocampus) and moderately high (thalamus) k3 values. The authors then applied these methods to [11C]MP4A PET data in 12 healthy subjects and 26 patients with Alzheimer disease (AD) using the cerebellum as the reference region. There was a highly significant linear correlation in regional k3 estimates between RLS and NLS analyses (456 cerebral regions, [RLS k3] = 0.98 × [NLS k3], r = 0.92, P < 0.001). Significant reductions were observed in k3 estimates of frontal, temporal, parietal, occipital, and sensorimotor cerebral neocortices ( P < 0.001, single-tailed t-test), and hippocampus ( P = 0.012) in patients with AD as compared with controls when using RLS analysis. Mean reductions (19.6%) Fin these 6 regions by RLS were almost the same as those by NLS analysis (20.5%). The sensitivity of RLS analysis for detecting cortical regions with abnormally low k3 in the 26 patients with AD (138 of 312 regions, 44%) was somewhat less than NLS analysis (52%), but was greater than shape analysis (33%), another method of [11C]MP4A kinetic analysis without blood sampling. The authors conclude that RLS analysis is practical and useful for routine analysis of clinical [11C]MP4A studies.


2021 ◽  
Author(s):  
Chao Zheng ◽  
Daniel Holden ◽  
Ming-Qiang Zheng ◽  
Richard Pracitto ◽  
Kyle C. Wilcox ◽  
...  

Purpose: To investigate the synaptic vesicle glycoprotein 2A (SV2A) expression in the whole central nervous system and peripheral tissues, a metabolically stable SV2A radiotracer is desirable to minimize a potential confounding effect of radiometabolites. The aim of this study was to develop and evaluate a metabolically stable SV2A radiotracer, [18F]SDM-16, in nonhuman primate brains. Methods: The racemic SDM-16 (4-(3,5-difluorophenyl)-1-((2-methyl-1H-imidazol-1-yl)methyl)pyrrolidin-2-one ) was synthesized and assayed for in vitro SV2A binding affinity. We synthesized the enantiopure [18F]SDM-16 using the corresponding arylstannane precursor. Nonhuman primate brain PET was performed on a FOCUS 220 system. Arterial blood was drawn for metabolite analysis and construction of plasma input function. Regional time-activity curves (TACs) were evaluated with the one-tissue compartment (1TC) model to obtain the volume of distribution (VT). Binding potential (BPND) was calculated using either the nondisplaceable volume of distribution (VND) or the centrum semiovale (CS) as the reference region. Results: Racemic SDM-16 was synthesized in 3 steps with 44% overall yield and has high affinity (Ki = 3.7 nM) to human SV2A. [18F]SDM-16 was prepared in greater than 99% radiochemical and enantiomeric purity. This radiotracer displayed high specific binding in brain and was metabolically more stable than other SV2A PET tracers. The plasma free fraction (fP) of [18F]SDM-16 was 69%, which was higher than those of [11C]UCB-J (46%), [18F]SynVesT-1 (43%), [18F]SynVesT-2 (41%), and [18F]UCB-H (43%). The TACs were well described with the 1TC. The averaged test-retest variability (TRV) was -9%, and averaged absolute TRV (aTRV) was 10% for all analyzed brain regions. Conclusion: We have successfully synthesized a metabolically stable and high affinity SV2A PET tracer, [18F]SDM-16, which showed high specific and reversible binding in the NHP brain. [18F]SDM-16 may have potential application in the visualization and quantification of SV2A beyond the brain.


2021 ◽  
Author(s):  
Chao Zheng ◽  
Daniel Holden ◽  
Ming-Qiang Zheng ◽  
Richard Pracitto ◽  
Kyle C. Wilcox ◽  
...  

Abstract PurposeTo investigate the synaptic vesicle glycoprotein 2A (SV2A) expression in the whole central nervous system and peripheral tissues, a metabolically stable SV2A radiotracer is desirable to minimize a potential confounding effect of radiometabolites. The aim of this study was to develop and evaluate a metabolically stable SV2A radiotracer, [18 F]SDM-16, in nonhuman primate brains. MethodsThe racemic SDM-16 (4-(3,5-difluorophenyl)-1-((2-methyl-1H-imidazol-1yl)methyl)pyrrolidin-2-one) was synthesized and assayed for in vitro SV2A binding affinity. We synthesized the enantiopure [18F]SDM-16 using the corresponding arylstannane precursor. Nonhuman primate brain PET was performed on a FOCUS 220 system. Arterial blood was drawn for metabolite analysis and construction of plasma input function. Regional time-activity curves (TACs) were evaluated with the one-tissue compartment (1TC) model to obtain the volume of distribution (VT). Binding potential (BPND) was calculated using either the nondisplaceable volume of distribution (VND) or the centrum semiovale (CS) as the reference region. ResultsRacemic SDM-16 was synthesized in 3 steps with 44% overall yield and has high affinity (K i = 3.7 nM) to human SV2A. [18F]SDM-16 was prepared in greater than 99% radiochemical and enantiomeric purity. This radiotracer displayed high specific binding in brain and was metabolically more stable than other SV2A PET tracers. The plasma free fraction (fP) of [ 18 F]SDM-16 was 69%, which was higher than those of [11C]UCB-J (46%), [18F]SynVesT-1 (43%), [18F]SynVesT-2 (41%), and [18F]UCB-H (43%). The TACs were well described with the 1TC. The averaged test-retest variability (TRV) was -9±8%, and averaged absolute TRV (aTRV) was 10±7% for all analyzed brain regions. ConclusionWe have successfully synthesized a metabolically stable and high affinity SV2A PET tracer, [18F]SDM-16, which showed high specific and reversible binding in the NHP brain. [18F]SDM-16 may have potential application in the visualization and quantification of SV2A beyond the brain.


2015 ◽  
Vol 12 (4) ◽  
pp. 1273-1287
Author(s):  
Ondřej Tichý ◽  
Václav Smídl

Selection of regions of interest in an image sequence is a typical prerequisite step for estimation of time-activity curves in dynamic positron emission tomography (PET). This procedure is done manually by a human operator and therefore suffers from subjective errors. Another such problem is to estimate the input function. It can be measured from arterial blood or it can be searched for a vascular structure on the images which is hard to be done, unreliable, and often impossible. In this study, we focus on blind source separation methods with no needs of manual interaction. Recently, we developed sparse blind source separation and deconvolution (S-BSS-vecDC) method for separation of original sources from dynamic medical data based on probability modeling and Variational Bayes approximation methodology. In this paper, we extend this method and we apply the methods on dynamic brain PET data and application and comparison of derived algorithms with those of similar assumptions are given. The S-BSS-vecDC algorithm is publicly available for download.