scholarly journals Primary Graft Failure, Infection, and Endothelial Cell Density in Corneal Transplants With Increased Death-to-Preservation Time

Cornea ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Michelle J. Sun ◽  
Andrew T. Duong ◽  
Khoa D. Tran ◽  
Megan M.W. Straiko ◽  
Christopher G. Stoeger ◽  
...  
2017 ◽  
Vol 47 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Dhaval Patel ◽  
Radhika Tandon ◽  
Anita Ganger ◽  
Aarti Vij ◽  
Sanjeev Lalwani ◽  
...  

To evaluate the impact of death-to-preservation time (DPT) on effective utilisation of donor corneas. In a prospective observational study conducted at our tertiary eye centre, donated corneas received over a 15-month period from November 2011 to January 2013 were evaluated. Donor age, donor refrigeration (done or not), DPT, endothelial cell density (ECD), corneal grading, clinical utilisation and surgical outcome after graft transplantation were noted. To analyse the impact of different DPT on donor cornea transplantation, primary outcome measures (corneal grading and endothelial cell density) and secondary outcome measures (primary graft failure and graft infection) were analysed. A total of 990 corneas were assessed. Primary outcomes showed no significant difference for higher DPT ( P > 0.01). ECD, where DPT was >12 h, was better for refrigerated corneas ( P < 0.001). Prolonged DPT had no significant effect on primary graft failure ( P = 0.131) and graft infection ( P = 0.137) in the first month after transplantation. We find that DPT should not be the only criteria to assess the cornea quality; other donor characteristics should be considered equally important. Donor refrigeration should be encouraged in cases where early retrieval is not possible.


Ophthalmology ◽  
2015 ◽  
Vol 122 (3) ◽  
pp. 448-456 ◽  
Author(s):  
Jonathan H. Lass ◽  
Tonya D. Riddlesworth ◽  
Robin L. Gal ◽  
Craig Kollman ◽  
Beth A. Benetz ◽  
...  

Ophthalmology ◽  
2019 ◽  
Vol 126 (8) ◽  
pp. 1076-1083 ◽  
Author(s):  
Sanjay V. Patel ◽  
Jonathan H. Lass ◽  
Beth Ann Benetz ◽  
Loretta B. Szczotka-Flynn ◽  
Nathan J. Cohen ◽  
...  

2020 ◽  
Vol 259 (1) ◽  
pp. 113-119
Author(s):  
Doreen Koechel ◽  
Nicola Hofmann ◽  
Jan D. Unterlauft ◽  
Peter Wiedemann ◽  
Christian Girbardt

Abstract Purpose This study aims to investigate possible differences in clinical outcomes between precut and surgeon-cut grafts for Descemet membrane endothelial keratoplasty (DMEK). Methods 142 consecutive patients who underwent DMEK were included in the study. 44 patients received precut tissues, and 98 patients received surgeon-cut tissues. Precut grafts were allocated to the patient by the German Society for Tissue Transplantation if available. We compared the outcomes of both groups for changes in visual acuity, central corneal thickness, endothelial cell density, re-bubbling rate, and graft failure rate. Results Patients who received precut tissues experienced similar increase in visual acuity (median change 0.4 logMAR) and decrease of corneal swelling (median change 132 μm) compared with those who received surgeon-cut tissues (median VA change 0.3 logMAR, p = 0.55, CCT change 118 μm, p = 0.63). There was no statistical difference in endothelial cell density (1436 vs. 1569 cells/mm2, p = 0.37), re-bubbling (32% vs. 35%, p = 0.85), and graft failure rate (5% vs. 1%, p = 0.23). No primary graft failure occurred in the group of precut grafts. Conclusion Both methods lead to comparable results for visual acuity, corneal deswelling, endothelial cell density, and re-bubbling rate. A previously described higher graft failure rate for precut tissues could not be confirmed in our study. Thus, we do not see medical reasons against the use of precut tissues. There are several advantages of precut DMEK tissues over surgeon-cut tissues, especially the prevention of graft loss during preparation in the operating theater.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Naohiko Aketa ◽  
Miki Uchino ◽  
Motoko Kawashima ◽  
Yuichi Uchino ◽  
Kenya Yuki ◽  
...  

AbstractThis population-based cross-sectional study was performed to determine the mean corneal endothelial cell density (ECD), coefficient of variation (CV), and hexagonality (HEX), and their associations with myopia in Japanese adults living in Chikusei city. Of 7109 participants with available data, 5713 (2331 male and 3382 female) participants were eligible for analysis. After assessing the relationship between participant characteristics and spherical equivalent refraction (SER), the association of SER with the abnormal value of ECD (< 2000 cells/mm), CV (≥ 0.40), and HEX (≤ 50%) were determined using the logistic regression models adjusting for potential confounders (age, intraocular pressure, keratometric power, height, and antihypertensive drug use). In male participants, there was no statistically significant relationships between SER and endothelial parameters. In female participants, compared to emmetropia, SER ≤ − 6 D had significantly higher odds ratio (OR) of having the abnormal value of CV (OR = 2.07, 95% confidence interval [CI] 1.39–3.10) and HEX (OR = 2.04, 95% CI 1.29–3.23), adjusted for potential confounders, indicating that the high myopia was associated with the abnormal values of CV and HEX. Further adjustment for contact lenses wear partly attenuated these associations. Association between the SER and ECD was not detected.


Author(s):  
Lei Shi ◽  
Fabian Norbert Fries ◽  
Kassandra Xanthopoulou ◽  
Tanja Stachon ◽  
Loay Daas ◽  
...  

Abstract Purpose To analyze endothelial cell density (ECD) and central corneal thickness (CCT) following penetrating keratoplasty (PKP) in Acanthamoeba keratitis (AK) patients. Patients and Methods In this retrospective, clinical, single-center, cross-sectional, observational study, patients were enrolled who underwent PKP at the Department of Ophthalmology of Saarland University Medical Center, Homburg/Saar, Germany between May 2008 and December 2016 with the diagnosis of AK. In all, 33 eyes of 33 patients (14 males, 42%) were enrolled; their mean age at the time of surgery was 39.5 ± 14.3 years. Postoperatively, AK patients received topical polyhexamethylene biguanide, propamidine isethionate, neomycin sulphate/gramicidin/polymixin B sulfate, and prednisolone acetate eye drops (5 ×/day each), and the topical treatment was tapered sequentially with 1 drop every 6 weeks over 6 months. CCT was recorded using Pentacam HR Scheimpflug tomography and ECD with the EM-3000 specular microscope before surgery and 3 and 6 months after surgery as well as after the first and second (complete) suture removal. Results ECD tended to decrease significantly from the time point before surgery (2232 ± 296 cells/mm2) to the time point 3 months after surgery (1914 ± 164 cells/mm2; p = 0.080) and to the time point after the first suture removal (1886 ± 557 cells/mm2; p = 0.066) and decrease significantly to the time point after the second suture removal (1650 ± 446 cells/mm2; p = 0.028). CCT did not change significantly over the analyzed time period (p ≥ 0.475). Conclusion In AK, endothelial cell loss does not seem to be accelerated following PKP, despite the postoperative use of diamidine and biguanide. A subsequent prospective comparative study should confirm our retrospective longitudinal analysis.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Tatsuya Jujo ◽  
Jiro Kogo ◽  
Hiroki Sasaki ◽  
Reio Sekine ◽  
Keiji Sato ◽  
...  

Abstract Backgrounds However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar. Methods Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o’clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications. Results The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was − 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred. Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.


Sign in / Sign up

Export Citation Format

Share Document