Sphenopalatine Foramen Computed Tomography Landmarks

2020 ◽  
Vol 31 (1) ◽  
pp. 210-213
Author(s):  
Mohammad Waheed El-Anwar ◽  
Alaa Omar Khazbak ◽  
Atef Hussein ◽  
Sameh Saber ◽  
Ahmed Awad Bessar ◽  
...  
2017 ◽  
Vol 8 (2) ◽  
pp. ar.2017.8.0196 ◽  
Author(s):  
Anne K. Maxwell ◽  
Henry P. Barham ◽  
Anne E. Getz ◽  
Todd T. Kingdom ◽  
Vijay R. Ramakrishnan

Background Transnasal endoscopic sphenopalatine artery ligation is becoming the procedure of choice for surgical management of intractable posterior epistaxis. Landmarks for localization of the sphenopalatine foramen can assist in rapid surgical exposure of the sphenopalatine artery. Objective This study examined distances from easily identified endoscopic surgical landmarks to the sphenopalatine foramen. Methods By using computed tomography of the sinus to study radiologic anatomy in 50 adults, distances were measured between five simple endoscopic landmarks and the sphenopalatine foramen. The two-tailed t-test was used for statistical analysis. Results Right- and left-sided measurements were similar. The mean (standard deviation [SD]) anteroposterior distances to the sphenopalatine foramen were the following: from the maxillary line (36.7 ± 5.5 mm), anterior head of the middle turbinate (33.8 ± 6.7 mm), basal lamella (11.8 ± 1.9 mm), and choanal arch (–9.2 ± 1.4 mm). The mean (SD) distance in the vertical dimension from the nasal floor was 26.6 ± 2.6 mm. Female patients had statistically shorter distances to the sphenopalatine foramen from the maxillary line, anterior head of the middle turbinate, choanal arch, and nasal floor. Conclusion Reliable endoscopic landmarks exist in relation to consistent anatomic structures and can be used to help quickly estimate the location of the sphenopalatine foramen at the onset of the procedure.


2015 ◽  
Vol 129 (S3) ◽  
pp. S47-S52 ◽  
Author(s):  
S Nalavenkata ◽  
C Meller ◽  
D Novakovic ◽  
M Forer ◽  
N P Patel

AbstractObjective:To establish whether nasal bony landmarks on computed tomography could be utilised reliably in endoscopic approaches to the sphenopalatine foramen.Methods:A prospective analysis of 102 consecutive helical computed tomography scans of the paranasal sinuses was carried out by 2 senior ENT surgeons. Distances from the sphenopalatine foramen to endoscopically palpable bony landmarks were measured.Results:There were a total of 102 patients (45 females and 57 males), with a mean age of 62 years. The mean distance from the posterior fontanelle to the sphenopalatine foramen was 14.1 mm (standard deviation = 2.13). The average vertical distance of the sphenopalatine foramen opening from the bony attachment of the inferior turbinate was 14.13 mm. There were no statistically significant differences between any of these measurements (foramen widthp-value = 0.714, distance from fontanellep-value = 0.43 and distance from inferior turbinatep-value = 0.48).Conclusion:Determination of reliable bony landmarks is clinically useful in endoscopic surgery and can aid identification of the sphenopalatine foramen. The inferior turbinate concha and posterior fontanelle may be used as reliable computed tomography landmarks for endoscopic approaches to the sphenopalatine foramen.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


2001 ◽  
Vol 120 (5) ◽  
pp. A3-A3
Author(s):  
C HASSAN ◽  
P CERRO ◽  
A ZULLO ◽  
C SPINA ◽  
S MORINI

Sign in / Sign up

Export Citation Format

Share Document