scholarly journals Estimating Assembly Base Errors Using K-mer Abundance Difference (KAD) Between Short Reads and Genome Assembled Sequences

Author(s):  
Cheng He ◽  
Guifang Lin ◽  
Hairong Wei ◽  
Haibao Tang ◽  
Frank F White ◽  
...  

ABSTRACTGenome sequences provide genomic maps with a single-base resolution for exploring genetic contents. Sequencing technologies, particularly long reads, have revolutionized genome assemblies for producing highly continuous genome sequences. However, current long-read sequencing technologies generate inaccurate reads that contain many errors. Some errors are retained in assembled sequences, which are typically not completely corrected by using either long reads or more accurate short reads. The issue commonly exists but few tools are dedicated for computing error rates or determining error locations. In this study, we developed a novel approach, referred to as K-mer Abundance Difference (KAD), to compare the inferred copy number of each k-mer indicated by short reads and the observed copy number in the assembly. Simple KAD metrics enable to classify k-mers into categories that reflect the quality of the assembly. Specifically, the KAD method can be used to identify base errors and estimate the overall error rate. In addition, sequence insertion and deletion as well as sequence redundancy can also be detected. Therefore, KAD is valuable for quality evaluation of genome assemblies and, potentially, provides a diagnostic tool to aid in precise error correction. KAD software has been developed to facilitate public uses.

2020 ◽  
Vol 2 (3) ◽  
Author(s):  
Cheng He ◽  
Guifang Lin ◽  
Hairong Wei ◽  
Haibao Tang ◽  
Frank F White ◽  
...  

Abstract Genome sequences provide genomic maps with a single-base resolution for exploring genetic contents. Sequencing technologies, particularly long reads, have revolutionized genome assemblies for producing highly continuous genome sequences. However, current long-read sequencing technologies generate inaccurate reads that contain many errors. Some errors are retained in assembled sequences, which are typically not completely corrected by using either long reads or more accurate short reads. The issue commonly exists, but few tools are dedicated for computing error rates or determining error locations. In this study, we developed a novel approach, referred to as k-mer abundance difference (KAD), to compare the inferred copy number of each k-mer indicated by short reads and the observed copy number in the assembly. Simple KAD metrics enable to classify k-mers into categories that reflect the quality of the assembly. Specifically, the KAD method can be used to identify base errors and estimate the overall error rate. In addition, sequence insertion and deletion as well as sequence redundancy can also be detected. Collectively, KAD is valuable for quality evaluation of genome assemblies and, potentially, provides a diagnostic tool to aid in precise error correction. KAD software has been developed to facilitate public uses.


BMC Genomics ◽  
2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Kelsi A. Lindblad ◽  
Jananan S. Pathmanathan ◽  
Sandrine Moreira ◽  
John R. Bracht ◽  
Robert P. Sebra ◽  
...  

Abstract Background Whole-genome shotgun sequencing, which stitches together millions of short sequencing reads into a single genome, ushered in the era of modern genomics and led to a rapid expansion of the number of genome sequences available. Nevertheless, assembly of short reads remains difficult, resulting in fragmented genome sequences. Ultimately, only a sequencing technology capable of capturing complete chromosomes in a single run could resolve all ambiguities. Even “third generation” sequencing technologies produce reads far shorter than most eukaryotic chromosomes. However, the ciliate Oxytricha trifallax has a somatic genome with thousands of chromosomes averaging only 3.2 kbp, making it an ideal candidate for exploring the benefits of sequencing whole chromosomes without assembly. Results We used single-molecule real-time sequencing to capture thousands of complete chromosomes in single reads and to update the published Oxytricha trifallax JRB310 genome assembly. In this version, over 50% of the completed chromosomes with two telomeres derive from single reads. The improved assembly includes over 12,000 new chromosome isoforms, and demonstrates that somatic chromosomes derive from variable rearrangements between somatic segments encoded up to 191,000 base pairs away. However, while long reads reduce the need for assembly, a hybrid approach that supplements long-read sequencing with short reads for error correction produced the most complete and accurate assembly, overall. Conclusions This assembly provides the first example of complete eukaryotic chromosomes captured by single sequencing reads and demonstrates that traditional approaches to genome assembly can mask considerable structural variation.


2019 ◽  
Vol 36 (7) ◽  
pp. 2253-2255 ◽  
Author(s):  
Jiang Hu ◽  
Junpeng Fan ◽  
Zongyi Sun ◽  
Shanlin Liu

Abstract Motivation Although long-read sequencing technologies can produce genomes with long contiguity, they suffer from high error rates. Thus, we developed NextPolish, a tool that efficiently corrects sequence errors in genomes assembled with long reads. This new tool consists of two interlinked modules that are designed to score and count K-mers from high quality short reads, and to polish genome assemblies containing large numbers of base errors. Results When evaluated for the speed and efficiency using human and a plant (Arabidopsis thaliana) genomes, NextPolish outperformed Pilon by correcting sequence errors faster, and with a higher correction accuracy. Availability and implementation NextPolish is implemented in C and Python. The source code is available from https://github.com/Nextomics/NextPolish. Supplementary information Supplementary data are available at Bioinformatics online.


2021 ◽  
Vol 3 (2) ◽  
Author(s):  
Jean-Marc Aury ◽  
Benjamin Istace

Abstract Single-molecule sequencing technologies have recently been commercialized by Pacific Biosciences and Oxford Nanopore with the promise of sequencing long DNA fragments (kilobases to megabases order) and then, using efficient algorithms, provide high quality assemblies in terms of contiguity and completeness of repetitive regions. However, the error rate of long-read technologies is higher than that of short-read technologies. This has a direct consequence on the base quality of genome assemblies, particularly in coding regions where sequencing errors can disrupt the coding frame of genes. In the case of diploid genomes, the consensus of a given gene can be a mixture between the two haplotypes and can lead to premature stop codons. Several methods have been developed to polish genome assemblies using short reads and generally, they inspect the nucleotide one by one, and provide a correction for each nucleotide of the input assembly. As a result, these algorithms are not able to properly process diploid genomes and they typically switch from one haplotype to another. Herein we proposed Hapo-G (Haplotype-Aware Polishing Of Genomes), a new algorithm capable of incorporating phasing information from high-quality reads (short or long-reads) to polish genome assemblies and in particular assemblies of diploid and heterozygous genomes.


2021 ◽  
Vol 10 (4) ◽  
Author(s):  
Håkon Kaspersen ◽  
Thomas H. A. Haverkamp ◽  
Hanna Karin Ilag ◽  
Øivind Øines ◽  
Camilla Sekse ◽  
...  

ABSTRACT In total, 12 quinolone-resistant Escherichia coli (QREC) strains containing qnrS1 were submitted to long-read sequencing using a FLO-MIN106 flow cell on a MinION device. The long reads were assembled with short reads (Illumina) and analyzed using the MOB-suite pipeline. Six of these QREC genome sequences were closed after hybrid assembly.


2015 ◽  
Author(s):  
Rene L Warren ◽  
Benjamin P Vandervalk ◽  
Steven JM Jones ◽  
Inanc Birol

Owing to the complexity of the assembly problem, we do not yet have complete genome sequences. The difficulty in assembling reads into finished genomes is exacerbated by sequence repeats and the inability of short reads to capture sufficient genomic information to resolve those problematic regions. Established and emerging long read technologies show great promise in this regard, but their current associated higher error rates typically require computational base correction and/or additional bioinformatics pre-processing before they could be of value. We present LINKS, the Long Interval Nucleotide K-mer Scaffolder algorithm, a solution that makes use of the information in error-rich long reads, without the need for read alignment or base correction. We show how the contiguity of an ABySS E. coli K-12 genome assembly could be increased over five-fold by the use of beta-released Oxford Nanopore Ltd. (ONT) long reads and how LINKS leverages long-range information in S. cerevisiae W303 ONT reads to yield an assembly with less than half the errors of competing applications. Re-scaffolding the colossal white spruce assembly draft (PG29, 20 Gbp) and how LINKS scales to larger genomes is also presented. We expect LINKS to have broad utility in harnessing the potential of long reads in connecting high-quality sequences of small and large genome assembly drafts. Availability: http://www.bcgsc.ca/bioinfo/software/links


BMC Genomics ◽  
2019 ◽  
Vol 20 (S11) ◽  
Author(s):  
Arghya Kusum Das ◽  
Sayan Goswami ◽  
Kisung Lee ◽  
Seung-Jong Park

Abstract Background Long-read sequencing has shown the promises to overcome the short length limitations of second-generation sequencing by providing more complete assembly. However, the computation of the long sequencing reads is challenged by their higher error rates (e.g., 13% vs. 1%) and higher cost ($0.3 vs. $0.03 per Mbp) compared to the short reads. Methods In this paper, we present a new hybrid error correction tool, called ParLECH (Parallel Long-read Error Correction using Hybrid methodology). The error correction algorithm of ParLECH is distributed in nature and efficiently utilizes the k-mer coverage information of high throughput Illumina short-read sequences to rectify the PacBio long-read sequences.ParLECH first constructs a de Bruijn graph from the short reads, and then replaces the indel error regions of the long reads with their corresponding widest path (or maximum min-coverage path) in the short read-based de Bruijn graph. ParLECH then utilizes the k-mer coverage information of the short reads to divide each long read into a sequence of low and high coverage regions, followed by a majority voting to rectify each substituted error base. Results ParLECH outperforms latest state-of-the-art hybrid error correction methods on real PacBio datasets. Our experimental evaluation results demonstrate that ParLECH can correct large-scale real-world datasets in an accurate and scalable manner. ParLECH can correct the indel errors of human genome PacBio long reads (312 GB) with Illumina short reads (452 GB) in less than 29 h using 128 compute nodes. ParLECH can align more than 92% bases of an E. coli PacBio dataset with the reference genome, proving its accuracy. Conclusion ParLECH can scale to over terabytes of sequencing data using hundreds of computing nodes. The proposed hybrid error correction methodology is novel and rectifies both indel and substitution errors present in the original long reads or newly introduced by the short reads.


2019 ◽  
Author(s):  
Laura H. Tung ◽  
Mingfu Shao ◽  
Carl Kingsford

AbstractThird-generation sequencing technologies benefit transcriptome analysis by generating longer sequencing reads. However, not all single-molecule long reads represent full transcripts due to incomplete cDNA synthesis and the sequencing length limit of the platform. This drives a need for long read transcript assembly. We quantify the benefit that can be achieved by using a transcript assembler on long reads. Adding long-read-specific algorithms, we evolved Scallop to make Scallop-LR, a long-read transcript assembler, to handle the computational challenges arising from long read lengths and high error rates. Analyzing 26 SRA PacBio datasets using Scallop-LR, Iso-Seq Analysis, and StringTie, we quantified the amount by which assembly improved Iso-Seq results. Through combined evaluation methods, we found that Scallop-LR identifies 2100–4000 more (for 18 human datasets) or 1100–2200 more (for eight mouse datasets) known transcripts than Iso-Seq Analysis, which does not do assembly. Further, Scallop-LR finds 2.4–4.4 times more potentially novel isoforms than Iso-Seq Analysis for the human and mouse datasets. StringTie also identifies more transcripts than Iso-Seq Analysis. Adding long-read-specific optimizations in Scallop-LR increases the numbers of predicted known transcripts and potentially novel isoforms for the human transcriptome compared to several recent short-read assemblers (e.g. StringTie). Our findings indicate that transcript assembly by Scallop-LR can reveal a more complete human transcriptome.


2018 ◽  
Author(s):  
Andrew J. Page ◽  
Jacqueline A. Keane

AbstractGenome sequencing is rapidly being adopted in reference labs and hospitals for bacterial outbreak investigation and diagnostics where time is critical. Seven gene multi-locus sequence typing is a standard tool for broadly classifying samples into sequence types, allowing, in many cases, to rule a sample in or out of an outbreak, or allowing for general characteristics about a bacterial strain to be inferred. Long read sequencing technologies, such as from PacBio or Oxford Nanopore, can produce read data within minutes of an experiment starting, unlike short read sequencing technologies which require many hours/days. However, the error rates of raw uncorrected long read data are very high. We present Krocus which can predict a sequence type directly from uncorrected long reads, and which was designed to consume read data as it is produced, providing results in minutes. It is the only tool which can do this from uncorrected long reads. We tested Krocus on over 600 samples sequenced with using long read sequencing technologies from PacBio and Oxford Nanopore. It provides sequence types on average within 90 seconds, with a sensitivity of 94% and specificity of 97%, directly from uncorrected raw sequence reads. The software is written in Python and is available under the open source license GNU GPL version 3.


2019 ◽  
Author(s):  
Aaron M. Wenger ◽  
Paul Peluso ◽  
William J. Rowell ◽  
Pi-Chuan Chang ◽  
Richard J. Hall ◽  
...  

AbstractThe major DNA sequencing technologies in use today produce either highly-accurate short reads or noisy long reads. We developed a protocol based on single-molecule, circular consensus sequencing (CCS) to generate highly-accurate (99.8%) long reads averaging 13.5 kb and applied it to sequence the well-characterized human HG002/NA24385. We optimized existing tools to comprehensively detect variants, achieving precision and recall above 99.91% for SNVs, 95.98% for indels, and 95.99% for structural variants. We estimate that 2,434 discordances are correctable mistakes in the high-quality Genome in a Bottle benchmark. Nearly all (99.64%) variants are phased into haplotypes, which further improves variant detection. De novo assembly produces a highly contiguous and accurate genome with contig N50 above 15 Mb and concordance of 99.998%. CCS reads match short reads for small variant detection, while enabling structural variant detection and de novo assembly at similar contiguity and markedly higher concordance than noisy long reads.


Sign in / Sign up

Export Citation Format

Share Document