scholarly journals Seroprevalence of Antibodies to SARS-CoV-2 in Healthcare Workers in Non-epidemic Region: A Hospital Report in Iwate Prefecture, Japan

Author(s):  
Akihiro Nakamura ◽  
Ryoichi Sato ◽  
Sanae Ando ◽  
Natsuko Oana ◽  
Eiji Nozaki ◽  
...  

AbstractBackgroundAs of June 18, 2020, Iwate is the only one of 47 prefectures in Japan with no confirmed coronavirus disease 2019 (COVID-19) cases. Serological survey for COVID-19 antibodies is crucial in area with low prevalence as well as epidemic area when addressing health and social issues caused by COVID-19.MethodsSerum samples from healthcare workers (n = 1,000, mean 40 ± 11 years) of Iwate Prefectural Central Hospital, Iwate, Japan were tested for the prevalence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies. Two laboratory-based quantitative tests (Abbott’s and Roche’s immunoassays) and one point-of-care (POC) qualitative test performed simultaneously. Sensitivity and specificity were 100%, 99.6% in Abbott’s immunoassay; 100%, 99.8% in Roche’s immunoassay; 97.8%, 94.6% in Alfa POC test, respectively.ResultsThe laboratory-based quantitative tests showed positive in 4 of 1,000 samples (0.4%) (95% CI: 0.01 to 0.79): 4/1,000 (0.4%) (95% CI: 0.01 to 0.79) in Abbott; 0/1,000 (0%) in Roche. Positive samples were not detected for both Abbott’s and Roche’s immunoassays. The POC qualitative test showed positive in 33 of 1,000 samples (3.3%) (95% CI: 2.19 to 4.41). There were no samples with simultaneous positive reaction for two quantitative tests and a POC test.ConclusionsInfected COVID-2 cases were not confirmed by a retrospective serological study in healthcare workers of our hospital. The POC qualitative tests with lower specificity have the potential for higher false positive reactions than the laboratory-based quantitative tests in areas with very low prevalence of COVID-19.

2021 ◽  
Author(s):  
M R Shincy ◽  
Vandana Govindan ◽  
H H Sudhakar ◽  
V T Venkatesha ◽  
K Padmapriya ◽  
...  

ABSTRACTBackgroundMedical professionals and researchers have been urging the need for wide and rapid testing of citizens in order to plan measures that can contain the spread of the virus. Antibody tests play an important role throughout the patient care pathway and are vital for the management and surveillance of the virus. Although RT-PCR is considered as the gold standard, serological tests based on antibodies are helpful for on-time detection. We performed one to one assessment of point-of-care lateral flow assay (POCTs), enzyme immunoassay (EIAs), electrochemiluminescence immunoassay (CLIA), to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG antibody.Materials and Methods611 healthcare workers were recruited between November and December 2020 at Central Research Laboratory, KIMS. Collected serum samples were analysed according to manufacturer’s protocol. The Standard Q IgG/IgM combo assay, Anti-SARS CoV-2 Human IgG ELISA, and the Elecsys® to measure the IgG titer of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).ResultsThe kits displayed a sensitivity of 61.2%,79.5%, 91.8% and specificity of 61.7%,64.1%,80.2% for the Standard Q IgG/IgM combo assay, Anti-SARS CoV-2 Human IgG ELISA, and the Elecsys® in order.ConclusionOur results indicate high sensitivity and specificity for the Elecsys® assay compared to Anti-SARS CoV-2 Human IgG ELISA, the Standard Q IgG/IgM combo assay.


2021 ◽  
pp. 45-48
Author(s):  
Shincy M R ◽  
Vandana Govindan ◽  
Sudhakar H H ◽  
Padmapriya K ◽  
Venkatesha V T ◽  
...  

Background: The detection of SARS-CoV-2 IgG is important to determine the course of COVID-19. Medical professionals and researchers have been urging the need for wide and rapid testing of citizens in order to plan measures that can contain the spread of the virus. Antibody tests play an important role throughout the patient care pathway and are vital for the management and surveillance of the virus. Although RTPCR is considered to be the gold standard, serological tests based on antibodies could be very helpful for on-time detection. We performed one to one assessment of electrochemiluminescence immunoassay, enzyme immunoassay (EIAs), and point-of-care lateral ow assay (POCTs) to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG antibody. Materials and Methods: 611 healthcare workers were recruited between November and December 2020 at Central Research Laboratory, KIMS. ® Collected serum samples were analysed using three commercially available assays: the Elecsys , Anti-SARS CoV-2 Human IgG ELISA, the Standard Q IgG/IgM combo assay following the manufacturer's protocol to measure the IgG titer of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Results:The kits displayed a sensitivity of 91.8%, 79.5% ,61.2% and a specicity of 80.2%, 64.1% ,61.7% in order. Conclusion: ® Our results indicate a high sensitivity and specicity for the Elecsys assay compared to Anti-SARS CoV-2 Human IgG ELISA, the Standard Q IgG/IgM combo assays.


2020 ◽  
Author(s):  
Danielle Dias Conte ◽  
Joseane Mayara Almeida Carvalho ◽  
Luciano Kleber de Souza Luna ◽  
Klinger Soares Faíco-Filho ◽  
Ana Helena Perosa ◽  
...  

AbstractSince the Coronavirus Disease 2019 (COVID-19) pandemic, Brazil has the third-highest number of confirmed cases and the second-highest number of recovered patients. SARS-CoV-2 detection by real-time RT-PCR is the gold standard in certified infrastructured laboratories. However, for large-scale testing, diagnostics should be fast, cost-effective, widely available, and deployed for the community, such as serological tests based on lateral flow immunoassay (LFIA) for IgM/IgG detection. We evaluated three different commercial point-of-care (POC) LFIAs for anti-SARS-CoV-2 IgM and IgG detection in capillary whole blood of 100 healthcare workers (HCW) previously tested by RT-PCR: 1) COVID-19 IgG/IgM BIO (Bioclin, Brazil), 2) Diagnostic kit for IgM/IgG Antibody to Coronavirus (SARS-CoV-2) (Livzon, China); and 3) SARS-CoV-2 Antibody Test (Wondfo, China). A total of 84 positives and 16 negatives HCW were tested. The data was also analyzed by the number of days post symptoms (DPS) in three groups: <30 (n=26), 30-59 (n=42), and >59 (n=16). Overall detection was 85.71%, 47.62%, and 44.05% for Bioclin, Livzon, and Wondfo, respectively, with a specificity of 100%, and 98.75% for Livzon on storage serum samples. Bioclin was more sensitive (p<0.01), regardless of the DPS. Thus, the Bioclin can be used as a POC test to monitor SARS-CoV-2 seroconversion in HCW.


2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


2020 ◽  
pp. 175717742097679
Author(s):  
Kordo Saeed ◽  
Emanuela Pelosi ◽  
Nitin Mahobia ◽  
Nicola White ◽  
Christopher Labdon ◽  
...  

Background: We report an outbreak of SARS coronavirus-2 (SARS-CoV-2) infection among healthcare workers (HCW) in an NHS elective healthcare facility. Methodology: A narrative chronological account of events after declaring an outbreak of SARS-CoV-2 among HCWs. As part of the investigations, HCWs were offered testing during the outbreak. These were: (1) screening by real-time reverse transcriptase polymerase chain reaction (RT- PCR) to detect a current infection; and (2) serum samples to determine seroprevalence. Results: Over 180 HCWs were tested by real-time RT-PCR for SARS-CoV-2 infection. The rate of infection was 15.2% (23.7% for clinical or directly patient-facing HCWs vs. 4.8% in non-clinical non-patient-facing HCWs). Of the infected HCWs, 57% were asymptomatic. Seroprevalence (SARS-CoV-2 IgG) among HCWs was 13%. It was challenging to establish an exact source for the outbreak. The importance of education, training, social distancing and infection prevention practices were emphasised. Additionally, avoidance of unnecessary transfer of patients and minimising cross-site working for staff and early escalation were highlighted. Establishing mass and regular screening for HCWs are also crucial to enabling the best care for patients while maintaining the wellbeing of staff. Conclusion: To our knowledge, this is the first UK outbreak report among HCWs and we hope to have highlighted some key issues and learnings that can be considered by other NHS staff and HCWs globally when dealing with such a task in future.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ernesta Cavalcanti ◽  
Maria Antonietta Isgrò ◽  
Domenica Rea ◽  
Lucia Di Capua ◽  
Giusy Trillò ◽  
...  

Abstract Background Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection and the resulting disease, coronavirus disease 2019 (COVID-19), have spread to millions of people globally, requiring the development of billions of different vaccine doses. The SARS-CoV-2 spike mRNA vaccine (named BNT162b2/Pfizer), authorized by the FDA, has shown high efficacy in preventing SARS-CoV-2 infection after administration of two doses in individuals 16 years of age and older. In the present study, we retrospectively evaluated the differences in the SARS-CoV-2 humoral immune response after vaccine administration in the two different cohorts of workers at the INT - IRCCS “Fondazione Pascale” Cancer Center (Naples, Italy): previously infected to SARS-CoV-2 subjects and not infected to SARS-CoV-2 subjects. Methods We determined specific anti-RBD (receptor-binding domain) titers against trimeric spike glycoprotein (S) of SARS-CoV-2 by Roche Elecsys Anti-SARS-CoV-2 S immunoassay in serum samples of 35 healthcare workers with a previous documented history of SARS-CoV-2 infection and 158 healthcare workers without, after 1 and 2 doses of vaccine, respectively. Moreover, geometric mean titers and relative fold changes (FC) were calculated. Results Both previously infected and not infected to SARS-CoV-2 subjects developed significant immune responses to SARS-CoV-2 after the administration of 1 and 2 doses of vaccine, respectively. Anti-S antibody responses to the first dose of vaccine were significantly higher in previously SARS-CoV-2-infected subjects in comparison to titers of not infected subjects after the first as well as the second dose of vaccine. Fold changes for subjects previously infected to SARS-CoV-2 was very modest, given the high basal antibody titer, as well as the upper limit of 2500.0 BAU/mL imposed by the Roche methods. Conversely, for naïve subjects, mean fold change following the first dose was low ($$ \overline{x} $$ x ¯ =1.6), reaching 3.8 FC in 72 subjects (45.6%) following the second dose. Conclusions The results showed that, as early as the first dose, SARS-CoV-2-infected individuals developed a remarkable and statistically significant immune response in comparison to those who did not contract the virus previously, suggesting the possibility of administering only one dose in previously SARS-CoV-2-infected subjects. FC for previously infected subjects should not be taken into account for the generally high pre-vaccination values. Conversely, FC for not infected subjects, after the second dose, were = 3.8 in > 45.0% of vaccinees, and ≤ 3.1 in 19.0%, the latter showing a potential susceptibility to further SARS-CoV-2 infection.


Biosensors ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 157
Author(s):  
Bárbara V. M. Silva ◽  
Marli T. Cordeiro ◽  
Marco A. B. Rodrigues ◽  
Ernesto T. A. Marques ◽  
Rosa F. Dutra

Zika virus (ZIKV) is a mosquito-borne infection, predominant in tropical and subtropical regions causing international concern due to the ZIKV disease having been associated with congenital disabilities, especially microcephaly and other congenital abnormalities in the fetus and newborns. Development of strategies that minimize the devastating impact by monitoring and preventing ZIKV transmission through sexual intercourse, especially in pregnant women, since no vaccine is yet available for the prevention or treatment, is critically important. ZIKV infection is generally asymptomatic and cross-reactivity with dengue virus (DENV) is a global concern. An innovative screen-printed electrode (SPE) was developed for amperometric detection of the non-structural protein (NS2B) of ZIKV by exploring the intrinsic redox catalytic activity of Prussian blue (PB), incorporated into a carbon nanotube–polypyrrole composite. Thus, this immunosensor has the advantage of electrochemical detection without adding any redox-probe solution (probe-less detection), allowing a point-of-care diagnosis. It was responsive to serum samples of only ZIKV positive patients and non-responsive to negative ZIKV patients, even if the sample was DENV positive, indicating a possible differential diagnosis between them by NS2B. All samples used here were confirmed by CDC protocols, and immunosensor responses were also checked in the supernatant of C6/36 and in Vero cell cultures infected with ZIKV.


Author(s):  
Emily J. Godbout ◽  
Rachel Pryor ◽  
Mary Harmon ◽  
Alison Montpetit ◽  
Joan Greer ◽  
...  

Author(s):  
Giuseppe Vetrugno ◽  
Daniele Ignazio La Milia ◽  
Floriana D’Ambrosio ◽  
Marcello Di Pumpo ◽  
Roberta Pastorino ◽  
...  

Healthcare workers are at the forefront against COVID-19, worldwide. Since Fondazione Policlinico Universitario A. Gemelli (FPG) IRCCS was enlisted as a COVID-19 hospital, the healthcare workers deployed to COVID-19 wards were separated from those with limited/no exposure, whereas the administrative staff were designated to work from home. Between 4 June and 3 July 2020, an investigation was conducted to evaluate the seroprevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoglobulin (IgG) antibodies among the employees of the FPG using point-of-care (POC) and venous blood tests. Sensitivity, specificity, and predictive values were determined with reverse-transcription polymerase chain reaction on nasal/oropharyngeal swabs as the diagnostic gold standard. The participants enrolled amounted to 4777. Seroprevalence was 3.66% using the POC test and 1.19% using the venous blood test, with a significant difference (p < 0.05). The POC test sensitivity and specificity were, respectively, 63.64% (95% confidence interval (CI): 62.20% to 65.04%) and 96.64% (95% CI: 96.05% to 97.13%), while those of the venous blood test were, respectively, 78.79% (95% CI: 77.58% to 79.94%) and 99.36% (95% CI: 99.07% to 99.55%). Among the low-risk populations, the POC test’s predictive values were 58.33% (positive) and 98.23% (negative), whereas those of the venous blood test were 92.86% (positive) and 98.53% (negative). According to our study, these serological tests cannot be a valid alternative to diagnose COVID-19 infection in progress.


Micromachines ◽  
2021 ◽  
Vol 12 (8) ◽  
pp. 882
Author(s):  
M. Munzer Alseed ◽  
Hamzah Syed ◽  
Mehmet Cengiz Onbasli ◽  
Ali K. Yetisen ◽  
Savas Tasoglu

Civil wars produce immense humanitarian crises, causing millions of individuals to seek refuge in other countries. The rate of disease prevalence has inclined among the refugees, increasing the cost of healthcare. Complex medical conditions and high numbers of patients at healthcare centers overwhelm the healthcare system and delay diagnosis and treatment. Point-of-care (PoC) testing can provide efficient solutions to high equipment cost, late diagnosis, and low accessibility of healthcare services. However, the development of PoC devices in developing countries is challenged by several barriers. Such PoC devices may not be adopted due to prejudices about new technologies and the need for special training to use some of these devices. Here, we investigated the concerns of end users regarding PoC devices by surveying healthcare workers and doctors. The tendency to adopt PoC device changes is based on demographic factors such as work sector, education, and technology experience. The most apparent concern about PoC devices was issues regarding low accuracy, according to the surveyed clinicians.


Sign in / Sign up

Export Citation Format

Share Document