scholarly journals Comparing two automated methods of DNA extraction from degraded skeletal remains

2020 ◽  
Author(s):  
Linda Rubinstein

AbstractDNA extraction from degraded skeletal samples is often particularly challenging. The difficulty derives from the fact that variable environment has significant effect on DNA preservation. During the years 2002-2015 unidentified degraded skeletal remains were accumulated at our institute, National Institute of Forensic Medicine (NIFM), most of them with none or partial DNA profile.As new methods rapidly emerge, we revisited the samples with partial DNA profiles. We have chosen to use these samples to compare two automated methods: Prepfiler Express BTA (Applied Biosystems) and QIAcube (Quiagen), in hope of acquiring a more complete DNA profile and eventually even make new identifications. In both methods a preparation step is required, after which the samples undergo automatic DNA extraction.The two protocols are based on different extraction methods. Fresh or non-problematic bone samples as the positive control gave the same results in both methods. In the degraded skeletal samples, the results were significantly better using the QIAcube method.

2010 ◽  
Vol 4 (5) ◽  
pp. 275-280 ◽  
Author(s):  
Hwan Young Lee ◽  
Myung Jin Park ◽  
Na Young Kim ◽  
Jeong Eun Sim ◽  
Woo Ick Yang ◽  
...  

2016 ◽  
Vol 66 (2) ◽  
pp. 187-202 ◽  
Author(s):  
Branimira Špoljarić ◽  
Maja Popović ◽  
Josip Crnjac ◽  
Zrinka Žderić Savatović ◽  
Martina Ratko ◽  
...  

Abstract Animal hairs are an apt surface for retention of forensic trace epithelial samples. The aim of this study was threefold: to evaluate different methods of sample collection (moistened and dry swabs) and DNA extraction (Chelex® 100 method, Qiagen EZ1® DNA Investigator Kit), as well as to examine the morphological differences of hair fibres between two species (dog, sheep) and their ultimate impact on sample collection and processing. Our preliminary findings suggest that the use of EZ1® DNA Investigator Kit yields donor DNA profiles of higher quality. The results of different sample collection methods have shown intraspecific variations that require further investigation. The ability of retention and subsequent extraction of trace DNA appears to be similar between the two species, despite significant morphological differences between their coat hairs.


2017 ◽  
Author(s):  
Maria A. Nieves-Colón ◽  
Andrew T. Ozga ◽  
William J. Pestle ◽  
Andrea Cucina ◽  
Vera Tiesler ◽  
...  

ABSTRACTObjectivesThe tropics harbor a large part of the world’s biodiversity and have a long history of human habitation. However, paleogenomics research in these climates has been constrained so far by poor ancient DNA yields. Here we compare the performance of two DNA extraction methods on ancient samples of teeth and petrous portions excavated from tropical and semitropical sites in Tanzania, Mexico, and Puerto Rico (N=12).Materials and MethodsAll samples were extracted twice, built into double-stranded sequencing libraries, and shotgun sequenced on the Illumina HiSeq 2500. The first extraction protocol, Method D, was previously designed for recovery of ultrashort DNA fragments from skeletal remains. The second, Method H, modifies the first by adding an initial EDTA wash and an extended digestion and decalcification step.ResultsNo significant difference was found in overall ancient DNA yields or post-mortem damage patterns recovered from samples extracted with either method, irrespective of tissue type. However, Method H samples had higher endogenous content and more mapped reads after quality-filtering, but also higher clonality. In contrast, samples extracted with Method D had shorter average DNA fragments.DiscussionBoth methods successfully recovered endogenous ancient DNA. But, since surviving DNA in ancient or historic remains from tropical contexts is extremely fragmented, our results suggest that Method D is the optimal choice for working with samples from warm and humid environments. Additional optimization of extraction conditions and further testing of Method H with different types of samples may allow for improvement of this protocol in the future.


2016 ◽  
Vol 52 ◽  
pp. 171-176
Author(s):  
M. Palkina ◽  
O. Metlitska

The aim of the research – adaptation, optimization and using of existing DNA extraction methods from bees’ biological material with the reagent «Chelex-100" under complex economic conditions of native laboratories, which will optimize labour costs and improve the economic performance of DNA extraction protocol. Materials and methods. In order to conduct the research the samples of honey bees’ biological material: queen pupae exuviae, larvae of drone brood, some adult bees’ bodies (head and thorax) were selected. Bowl and drone brood were obtained from the experimental bee hives of Institute of Apiculture nd. a. P. I. Prokopovich of NAAS. DNA extraction from biosamples of Apis mellifera ssp. was carried out using «Chelex-100®» ion exchange resin in different concentrations and combinations. Before setting tests for determination of quantitative and quality indexes, dilution of DNA samples of the probed object was conducted in ratio 1:40. The degree of contamination with protein and polysaccharide fractions (OD 260/230), quantitative content of DNA (OD 260/280) in the extracted tests were conducted using spectrophotometer of «Biospec – nano» at the terms of sample volume in 2 µl and length of optical way in 0,7 mm [7]. Verification of DNA samples from biological material of bees, isolated by «Chelex-100®», was conducted after cold keeping during 24 hours at 20°C using PСR with primaries to the fragment of gene of quantitative trait locus (QTL) Sting-2 of next structure [8]:  3' – CTC GAC GAG ACG ACC AAC TTG – 5’; 3' – AAC CAG AGT ATC GCG AGT GTT AC – 5’ Program of amplification: 94 °C – 5 minutes – 1 cycle; 94 °C – 1 minute, 57°C – 1 minute, 72 °C – 2 minutes – 30 cycles; elongation after 72°C during 2 minutes – 1 cycle. The division of obtained amplicons was conducted by gel electrophoresis at a low current – 7 µÀ, in 1,5 % agarose gel (Sigma ®) in TAE buffer [7]. The results. At the time of optimization of DNA isolation methods, according to existing methods of foreign experts, it was found optimal volume of ion exchange resin solution was in the proposed concentration: instead of 60 µl of solution used 120 µl of «Chelex-100®», time of incubation was also amended from 30 minutes to 180 minutes [9]. The use of the author's combination of method «Chelex-100®» with lysis enzymes, proteinase K and detergents (1M dithiothreitol), as time of incubation was also amended, which was reduced to 180 minutes instead of the proposed 12 hours [10]. Changes in quality characteristics of obtained DNA in samples after reduction in incubation time were not found. Conclusions. The most economical method of DNA isolation from bees’ biological material is 20% solution of «Chelex-100» ion exchange resin with the duration of the incubation period of 180 minutes. It should also be noted that the best results can be obtained from exuviae, selected immediately after the queen’s exit from bowl, that reduces the likelihood of DNA molecules destruction under the influence of nucleases activation, but not later than 12 hours from release using the technology of isolated obtain of queens.


Genes ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 146
Author(s):  
Catarina Xavier ◽  
Mayra Eduardoff ◽  
Barbara Bertoglio ◽  
Christina Amory ◽  
Cordula Berger ◽  
...  

The efficient extraction of DNA from challenging samples, such as bones, is critical for the success of downstream genotyping analysis in molecular genetic disciplines. Even though the ancient DNA community has developed several protocols targeting small DNA fragments that are typically present in decomposed or old specimens, only recently forensic geneticists have started to adopt those protocols. Here, we compare an ancient DNA extraction protocol (Dabney) with a bone extraction method (Loreille) typically used in forensics. Real-time quantitative PCR and forensically representative typing methods including fragment size analysis and sequencing were used to assess protocol performance. We used four bone samples of different age in replicates to study the effects of both extraction methods. Our results confirm Loreille’s overall increased gain of DNA when enough tissue is available and Dabney’s improved efficiency for retrieving shorter DNA fragments that is beneficial when highly degraded DNA is present. The results suggest that the choice of extraction method needs to be based on available sample, degradation state, and targeted genotyping method. We modified the Dabney protocol by pooling parallel lysates prior to purification to study gain and performance in single tube typing assays and found that up to six parallel lysates lead to an almost linear gain of extracted DNA. These data are promising for further forensic investigations as the adapted Dabney protocol combines increased sensitivity for degraded DNA with necessary total DNA amount for forensic applications.


2021 ◽  
Vol 11 (4) ◽  
pp. 1943
Author(s):  
Joo-Young Kim ◽  
Ju Yeon Jung ◽  
Da-Hye Kim ◽  
Seohyun Moon ◽  
Won-Hae Lee ◽  
...  

Analytical techniques such as DNA profiling are widely used in various fields, including forensic science, and novel technologies such as direct polymerase chain reaction (PCR) amplification are continuously being developed in order to acquire DNA profiles efficiently. However, non-specific amplification may occur depending on the quality of the crime scene evidence and amplification methods employed. In particular, the ski-slope effect observed in direct PCR amplification has led to inaccurate interpretations of the DNA profile results. In this study, we aimed to reduce the ski-slope effect by using dimethyl sulfoxide (DMSO) in direct PCR. We confirmed that DMSO (3.75%, v/v) increased the amplification yield of large-sized DNA sequences more than that of small-sized ones. Using 50 Korean buccal samples, we further demonstrated that DMSO reduced the ski-slope effect in direct PCR. These results suggest that the experimental method developed in this study is suitable for direct PCR and may help to successfully obtain DNA profiles from various types of evidence at crime scenes.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1989
Author(s):  
Laura Téblick ◽  
Severien Van Keer ◽  
Annemie De Smet ◽  
Pierre Van Damme ◽  
Michelle Laeremans ◽  
...  

The potential of first-void (FV) urine as a non-invasive liquid biopsy for detection of human papillomavirus (HPV) DNA and other biomarkers has been increasingly recognized over the past decade. In this study, we investigated whether the volume of this initial urine stream has an impact on the analytical performance of biomarkers. In parallel, we evaluated different DNA extraction protocols and introduced an internal control in the urine preservative. Twenty-five women, diagnosed with high-risk HPV, provided three home-collected FV urine samples using three FV urine collection devices (Colli-Pee) with collector tubes that differ in volume (4, 10, 20 mL). Each collector tube was prefilled with Urine Conservation Medium spiked with phocine herpesvirus 1 (PhHV-1) DNA as internal control. Five different DNA extraction protocols were compared, followed by PCR for GAPDH and PhHV-1 (qPCR), HPV DNA, and HBB (HPV-Risk Assay), and ACTB (methylation-specific qPCR). Results showed limited effects of collection volume on human and HPV DNA endpoints. In contrast, significant variations in yield for human endpoints were observed for different DNA extraction methods (p < 0.05). Additionally, the potential of PhHV-1 as internal control to monitor FV urine collection, storage, and processing was demonstrated.


Sign in / Sign up

Export Citation Format

Share Document