scholarly journals Application of UV-cured resin as embedding/mounting media for practical, time-saving otolith specimen preparation

2018 ◽  
Author(s):  
Carlos Augusto Strüssmann ◽  
Kaho Miyoshi ◽  
Shota Mitsui

AbstractOtoliths are calcified structures located in the inner ears of fish, as in most vertebrates, that are responsible primarily for the perception of gravity, balance and movement, and secondarily of sound detection. Microstructural and chemical analyzes of the inner otolith growth layers, called increments, constitute powerful tools to estimate fish age and elucidate many life history and demographic traits of fish populations. Otolith analyzes often require the production of a thin cross section that includes in the same plane of view the otolith core and all microscopic layers formed from birth until the moment of collection (otolith edge). Here we report on the usefulness of UV-cured resins that have become recently popular among nail artists and hobbyists for otolith specimen preparation. We show that single-component UV-cured resins can replace successfully and advantageously the commonly used two-component Epoxy resins to obtain otolith cross sections suitable for both microstructural examination and chemical analysis by electron probe microanalysis. UV-cured resins provide on-demand, extremely rapid (minute-order) hardening and high transparency, while providing similar adhesion and mechanical support for the otoliths during processing and analysis as Epoxy resins. UV-cured resins may revolutionize otolith specimen preparation practically- and time-wise, and may be particularly useful in teaching and workshop situations in which time for otolith embedding is a constraint.

Author(s):  
R. W. Anderson ◽  
D. L. Senecal

A problem was presented to observe the packing densities of deposits of sub-micron corrosion product particles. The deposits were 5-100 mils thick and had formed on the inside surfaces of 3/8 inch diameter Zircaloy-2 heat exchanger tubes. The particles were iron oxides deposited from flowing water and consequently were only weakly bonded. Particular care was required during handling to preserve the original formations of the deposits. The specimen preparation method described below allowed direct observation of cross sections of the deposit layers by transmission electron microscopy.The specimens were short sections of the tubes (about 3 inches long) that were carefully cut from the systems. The insides of the tube sections were first coated with a thin layer of a fluid epoxy resin by dipping. This coating served to impregnate the deposit layer as well as to protect the layer if subsequent handling were required.


Author(s):  
J. S. Wall

The forte of the Scanning transmission Electron Microscope (STEM) is high resolution imaging with high contrast on thin specimens, as demonstrated by visualization of single heavy atoms. of equal importance for biology is the efficient utilization of all available signals, permitting low dose imaging of unstained single molecules such as DNA.Our work at Brookhaven has concentrated on: 1) design and construction of instruments optimized for a narrow range of biological applications and 2) use of such instruments in a very active user/collaborator program. Therefore our program is highly interactive with a strong emphasis on producing results which are interpretable with a high level of confidence.The major challenge we face at the moment is specimen preparation. The resolution of the STEM is better than 2.5 A, but measurements of resolution vs. dose level off at a resolution of 20 A at a dose of 10 el/A2 on a well-behaved biological specimen such as TMV (tobacco mosaic virus). To track down this problem we are examining all aspects of specimen preparation: purification of biological material, deposition on the thin film substrate, washing, fast freezing and freeze drying. As we attempt to improve our equipment/technique, we use image analysis of TMV internal controls included in all STEM samples as a monitor sensitive enough to detect even a few percent improvement. For delicate specimens, carbon films can be very harsh-leading to disruption of the sample. Therefore we are developing conducting polymer films as alternative substrates, as described elsewhere in these Proceedings. For specimen preparation studies, we have identified (from our user/collaborator program ) a variety of “canary” specimens, each uniquely sensitive to one particular aspect of sample preparation, so we can attempt to separate the variables involved.


2021 ◽  
Vol 1 ◽  
pp. 487-496
Author(s):  
Pavan Tejaswi Velivela ◽  
Nikita Letov ◽  
Yuan Liu ◽  
Yaoyao Fiona Zhao

AbstractThis paper investigates the design and development of bio-inspired suture pins that would reduce the insertion force and thereby reducing the pain in the patients. Inspired by kingfisher's beak and porcupine quills, the conceptual design of the suture pin is developed by using a unique ideation methodology that is proposed in this research. The methodology is named as Domain Integrated Design, which involves in classifying bio-inspired structures into various domains. There is little work done on such bio-inspired multifunctional aspect. In this research we have categorized the vast biological functionalities into domains namely, cellular structures, shapes, cross-sections, and surfaces. Multi-functional bio-inspired structures are designed by combining different domains. In this research, the hypothesis is verified by simulating the total deformation of tissue and the needle at the moment of puncture. The results show that the bio-inspired suture pin has a low deformation on the tissue at higher velocities at the puncture point and low deformation in its own structure when an axial force (reaction force) is applied to its tip. This makes the design stiff and thus require less force of insertion.


1953 ◽  
Vol 20 (1) ◽  
pp. 122-130
Author(s):  
Julius Miklowitz

Abstract In some tensile tests with brittle materials, it was noted that fractures were produced at two different cross sections of the specimen when the rupture load was reached. The phenomenon of the second fracture prompted the present investigation. It is believed that the second fracture is caused by the destructive action of the elastic strain waves created during the first of the two fractures. The analytical and experimental work carried out was focused on describing the character of these waves. Consideration of the mechanics involved reduces the problem to that of a vibrating cantilever beam with time-dependent boundary conditions. Two types of waves are shown to exist. The first is a longitudinal unloading wave (compression). The other is a group of flexural strain waves caused by the moment that develops at the initial fracture section. The methods of operational mathematics and the electric-analog computer have been employed in the analytical study.


2006 ◽  
Vol 983 ◽  
Author(s):  
Yuhong Wu ◽  
Meng Qu ◽  
Lucille A Giannuzzi ◽  
Sanjay Sampath ◽  
Andrew Gouldstone

AbstractThermally sprayed (TS) coatings are widely used for surface engineering across a range of industries, including aerospace, infrastructure and biomedical. TS materials are formed via the successive impingement, rapid quenching and build-up of molten powder particles on a substrate. The impacted ‘splats’ are thus the fundamental microstructural constituents of the coatings, and their intrinsic properties, as well as intersplat bonding and morphology, dictate coating behavior. Beyond the obvious practical considerations, from a scientific standpoint, splats represent a fascinating template for study, due to the highly non-equilibrium processing conditions (rapid deceleration from sub-sonic velocities, million-degree/sec cooling rates). In the literature, many studies of isolated splats on substrates have been carried out, but these have focused on overall morphology (disc-shape vs fragmented). Direct observations of microstructure, in particular cross-section, are limited in the specimen preparation stage due to splat size (tens of microns in diameter, 1-2 microns in thickness). However, Focused Ion Beam (FIB) techniques have allowed this problem to be addressed in a robust manner; in this paper we will discuss such approaches to observe Ni5Al splats on stainless steel substrates. Cross-sections through the splat and the substrate were created by recourse to ion milling and the ion beam itself provided good channeling contrast for grain imaging. The typical splat microstructure with sub-micron Ni(Al) columnar grains, a chill zone at the bottom and a lift off area is observed in high detail. In addition, an amorphous aluminum oxide top layer of 100-200 nm is partially present on top of the Ni(Al) columnar grains. At the splat/substrate interface, defects such as micro- and nano-scale pores were characterized for the first time and will be discussed. These observations provide insights into splat and interface formation during the deposition process and may drastically improve our current understanding of Ni5Al splat properties.


1937 ◽  
Vol 10 (4) ◽  
pp. 778-786
Author(s):  
R. Ariano

Abstract The results of tests of the brittleness of ebonite are described. Resilience is influenced chiefly by the moment of inertia of the cross section of the test-specimen, but it seems also to be affected by the form of the specimen. The state of vulcanization has considerable influence on these mechanical properties within the undercured range, but with thorough vulcanization the state of cure plays no appreciable part. Notching of test-specimens is not of great importance. It diminishes the resilience, but when the tests are compared on a basis of equal moments of inertia of the resistant cross sections, this diminution becomes inappreciable in the case of brittle ebonites. On the other hand, the shape of the notch in ebonites containing no loading ingredients does influence the resilience. With V-shaped notches, the depth of the notch and its angle of aperture influence considerably the resilience of this latter type of ebonite, and notches of minimum depth are sufficient to have an appreciable effect.


2015 ◽  
Vol 799-800 ◽  
pp. 251-255 ◽  
Author(s):  
Adeel Zafar ◽  
Mokhtar Awang ◽  
Sajjad Raza Khan ◽  
Sattar Emamian

Friction stir welding (FSW) of polymers is relatively a new concept among modern polymer joining techniques. This study demonstrates the applicability of FSW on 16mm thick nylon-6 plates at constant welding rate of 25mm/min and varying rotational speed between 300 to 1000RPM. A special designed tool was fabricated which has double shoulder and right-hand threaded pin profile. It has shown excellent results at relatively lower rotation speeds. Visual inspection and microstructural examination of cross sections showed that the cavities and tunnel defects appeared only at higher rotational speeds. A linear relationship was observed between temperature and rotation speed.


1987 ◽  
Vol 115 ◽  
Author(s):  
T. Boone ◽  
S. Nakahara

ABSTRACTA technique for observing both plan view and cross sections of a specimen directly in a transmission electron microscope (TEM) without relying on a tedious thinning operation was developed. This technique involves cleaving a specimen perpendicular to the plane, so that the thin (electron transparent) section of the cleaved edge can be directly imaged by TEM. The only limitations of this technique are that a specimen must be readily criacked or cleaved and that, since the transparent region is often bounded by a 90° corner, the extent of electron transparent region is somewhat localized. Nevertheless, the technique has the advantages of the ease of specimen preparation, and the absence of contamination or damage introduced in other conventional thinning methods. The geometry of the cleaved specimen is also suitable for reflection electron microscopy.


1879 ◽  
Vol 29 (196-199) ◽  
pp. 493-505

1. It is not necessary to enter into the question of the advisability of employing continuous girders in bridges with spans of less than 200 feet, but it is generally conceded that the increased economy due to the employment of continuous girders in longer spans more than counterbalances the well-known practical objections to continuity. Hence the practical solution of the general problem—given the conditions at the ends of a continuous girder, the spans, the moment of inertia of all cross sections, and the loading, to find the bending moment and shearing stress in every cross-section, is not unworthy of our attention.


1991 ◽  
Vol 254 ◽  
Author(s):  
John Benedict ◽  
Ron Anderson ◽  
Stanley J. Klepeis

AbstractCross sections of material specimens for TEM analysis must be produced in the shortest time possible, contain few, if any, artifacts and have a large area available for analysis. The analyst must also be able to prepare these cross sections from specified areas of complex, heterogeneous structures on a routine, reproducible basis to meet the growing needs of the semiconductor industry for TEM analysis. The specimen preparation spatial resolution required for preparing precision cross sections is substantially less than one micron. Cross sections meeting these requirements can be prepared by mounting a specimen to the Tripod Polisher and mechanically polishing on one side of the specimen, using a sequence of progressively finer grit diamond lapping films, until the area of interest is reached. This polished surface is then very briefly polished on a cloth wheel with colloidal silica to attain the final polish on that side. The specimen is then flipped over on the Tripod Polisher and polished from the other side, using same sequence of diamond lapping films to reach the predefined area of interest. The Tripod Polisher is set at a slight angle, to produce a tapered, wedge-shaped specimen, which has the area of interest at the thinnest edge of the taper. The specimen is polished with the diamond lapping films and the colloidal silica until it is 1000 Angstroms or less in thickness. The specimen is removed from the polisher and mounted on a 2 × 1mm slotted grid with M-Bond 610 epoxy. After the epoxy is cured the specimen can be taken directly to the microscope for analysis. The need for ion milling has been eliminated or reduced to a few minutes in most of our work because of the thinness of the final specimen. The total specimen preparation time is between 2.5 and 4 hours, depending on the specimen and the size of the specified area. The area available for analysis ranges from 0.5mm up to the full size of the mounting grid opening. The wedge shape of the specimen provides the mechanical stability needed for a long thin specimen.


Sign in / Sign up

Export Citation Format

Share Document