scholarly journals Strain distribution in an Si single crystal measured by interference fringes of X-ray mirage diffraction

2013 ◽  
Vol 46 (5) ◽  
pp. 1261-1265 ◽  
Author(s):  
Sukswat Jongsukswat ◽  
Tomoe Fukamachi ◽  
Dongying Ju ◽  
Riichirou Negishi ◽  
Keiichi Hirano ◽  
...  

In X-ray interference fringes accompanied by mirage diffraction, variations have been observed in the spacing and position of the fringes from a plane-parallel Si single crystal fixed at one end as a function of distance from the incident plane of the X-rays to the free crystal end. The variations can be explained by distortion of the sample crystal due to gravity. From the variations and positions of the fringes, the strain gradient of the crystal has been determined. The distribution of the observed strain agrees with that expected from rod theory except for residual strain. When the distortion is large, the observed strain distribution does not agree with that expected from rod theory.

2019 ◽  
Vol 75 (6) ◽  
pp. 842-850
Author(s):  
Tomoe Fukamachi ◽  
Sukswat Jongsukswat ◽  
Dongying Ju ◽  
Riichirou Negishi ◽  
Keiichi Hirano ◽  
...  

Under the anomalous transmission condition in the Bragg mode, X-ray interference fringes were observed between two beams with different hyperbolic trajectories in a very weakly bent plane-parallel perfect crystal with negative strain gradient. The origin of the fringes was analysed based on the dynamical theory of diffraction for a distorted crystal. In the reflected beam from the entrance surface, the interference fringes were observed between once- and twice-reflected beams from the back surface. In the transmitted beam from the back surface, the interference fringes were observed between the direct beam and once-reflected beam from the entrance surface. In the emitted beam from the lateral surface, the interference fringes were observed between the beams after different numbers of reflections in the crystal. The multiply reflected beams were formed by a combined result of long propagation length along the beam direction with large divergence of the refracted beams when the strain gradient was negative. The period of these interference fringes was sensitive to very weak strain, of the order of 10−7.


2014 ◽  
Vol 70 (a1) ◽  
pp. C187-C187
Author(s):  
Alison Edwards

"The renaissance in Laue studies - at neutron sources - provides us with access to single crystal neutron diffraction data for synthetic compounds without requiring synthesis of prohibitively large amounts of compound or improbably large crystals. Such neutron diffraction studies provide vital data where proof of the presence or absence of hydrogen in particular locations is required and which cannot validly be proved by X-ray studies. Since the commissioning of KOALA at OPAL in 2009[1] we have obtained numerous data sets which demonstrate the vital importance of measuring data even where the extent of the diffraction pattern is at relatively low resolution - especially when compared to that obtainable for the same compound with X-rays. In the Laue experiment performed with a fixed radius detector, data reduction is only feasible for crystals in the ""goldilocks"" zone – where the unit cell is relatively large for the detector, a correspondingly low resolution diffraction pattern in which adjacent spots are less affected by overlap will yield more data against which a structure can be refined than a pattern of higher resolution – one where neighbouring spots overlap rendering both unusable (in our current methodology). Analogous application of powder neutron diffraction in such determinations is also considered. Single crystal neutron diffraction studies of several important compounds (up to 5KDa see figure below)[2] in which precise determination of hydride content by neutron diffraction was pivotal to the final formulation will be presented. The neutron data sets typically possess 20% or fewer unique data at substantially "lower resolution" than the corresponding X-ray data sets. Careful refinement clearly reveals chemical detail which is typically unexplored in related X-ray diffraction studies reporting high profile chemistry despite the synthetic route being one which hydride ought to be considered/excluded in product formulation."


1998 ◽  
Vol 62 (1) ◽  
pp. 65-75 ◽  
Author(s):  
P. F. Schofield ◽  
G. van der Laan ◽  
C. M. B. Henderson ◽  
G. Cressey

AbstractThe Fe 2p X-ray absorption spectra of single crystal gillespite, BaFeSi4O10, show a strong linear dichroism, i.e. a large difference in the absorption when measured with the polarization of the X-rays either parallel or perpendicular to the plane of the FeO4 group. The isotropic spectrum, obtained from measurement at the ‘magic angle’, and the polarization dependent spectra have been compared to atomic multiplet calculations and show an excellent agreement with theory. Analysis of the branching ratio, the linear dichroism, and the detailed peak structure confirms that the 5A1 level is the ground state at room temperature and pressure. The 5B2 level is sufficiently low in energy that a distortion of the electronic charge density, induced by increased pressure, may result in a 5B2 ground state.


2009 ◽  
Vol 1217 ◽  
Author(s):  
Lincoln Miara ◽  
Louis Piper ◽  
Jacob Nathan Davis ◽  
Laxmikant Saraf ◽  
Tiffany Kaspar ◽  
...  

AbstractA system to grow heteroepitaxial thin-films of solid oxide fuel cell (SOFC) cathodes on single crystal substrates was developed. The cathode composition investigated was 20% strontium-doped lanthanum manganite (LSM) grown by pulsed laser deposition (PLD) on single crystal (111) yttria-stabilized zirconia (YSZ) substrates. By combining electrochemical impedance spectroscopy (EIS) with x-ray photoemission spectroscopy (XPS) and x-ray absorption spectroscopy XAS measurements, we conclude that electrically driven cation migration away from the two-phase gas-cathode interface results in improved electrochemical performance. Our results provide support to the premise that the removal of surface passivating phases containing Sr2+ and Mn2+, which readily form at elevated temperatures even in O2 atmospheric pressures, is responsible for the improved cathodic performance upon application of a bias.


2019 ◽  
Vol 26 (3) ◽  
pp. 756-761
Author(s):  
Yoko Takeo ◽  
Hiroto Motoyama ◽  
Yasunori Senba ◽  
Hikaru Kishimoto ◽  
Haruhiko Ohashi ◽  
...  

Probing the spatial coherence of X-rays has become increasingly important when designing advanced optical systems for beamlines at synchrotron radiation sources and free-electron lasers. Double-slit experiments at various slit widths are a typical method of quantitatively measuring the spatial coherence over a wide wavelength range including the X-ray region. However, this method cannot be used for the analysis of spatial coherence when the two evaluation points are separated by a large distance of the order of millimetres owing to the extremely narrow spacing between the interference fringes. A Fresnel-mirror-based optical system can produce interference patterns by crossing two beams from two small mirrors separated in the transverse direction to the X-ray beam. The fringe spacing can be controlled via the incidence angles on the mirrors. In this study, a Fresnel-mirror-based optical system was constructed at the soft X-ray beamline (BL25SU) of SPring-8. The relationship between the coherence and size of the virtual source was quantitatively measured at 300 eV in both the vertical and horizontal directions using the beam. The results obtained indicate that this is a valuable method for the optimization of optical systems along beamlines.


X -ray and microscopic examinations of multilayers of certain long-chain esters deposited on transparent bases have been made. An X -ray photograph of a stationary multilayer of ethyl stearate is apparently identical with that obtained by rotating a single crystal of β -ethyl stearate about the long axis of the cell. The spots previously observed on oscillation photographs of multilayers of ethyl stearate are in reality parts of circles, successive arcs of which appear on increasing the angle of incidence of the X -rays on the multilayer. These facts reveal that the multilayer consists of microcrystals all oriented with one axis in common, this axis being the normal to the surface of the multilayer. The single crystals appear to have grown without interruption throughout the entire thickness of the multilayer, which in these investigations was about 1000 mol. thick.


Sign in / Sign up

Export Citation Format

Share Document