Hard and soft X-ray imaging to resolve human ovarian cortical structures

2019 ◽  
Vol 26 (4) ◽  
pp. 1322-1329 ◽  
Author(s):  
Lorella Pascolo ◽  
Gabriela Sena ◽  
Alessandra Gianoncelli ◽  
Alice Cernogoraz ◽  
Geroge Kourousias ◽  
...  

Laboratory and synchrotron X-ray tomography are powerful tools for non-invasive studies of biological samples at micrometric resolution. In particular, the development of phase contrast imaging is enabling the visualization of sample details with a small range of attenuation coefficients, thus allowing in-depth analyses of anatomical and histological structures. Reproductive medicine is starting to profit from these techniques, mainly applied to animal models. This study reports the first imaging of human ovarian tissue where the samples consisted of surgically obtained millimetre fragments, properly fixed, stained with osmium tetroxide and included in epoxydic resin. Samples were imaged by the use of propagation phase contrast synchrotron radiation micro-computed tomography (microCT), obtained at the SYRMEP beamline of Elettra light source (Trieste, Italy), and X-ray absorption microCT at the Theoretical Biology MicroCT Imaging Laboratory in Vienna, Austria. The reconstructed microCT images were compared with the soft X-ray absorption and phase contrast images acquired at the TwinMic beamline of Elettra in order to help with the identification of structures. The resulting images allow the regions of the cortex and medulla of the ovary to be distinguished, identifying early-stage follicles and visualizing the distribution of blood vessels. The study opens to further application of micro-resolved 3D imaging to improve the understanding of human ovary's structure and support diagnostics as well as advances in reproductive technologies.

2021 ◽  
Vol 11 (7) ◽  
pp. 2971
Author(s):  
Siwei Tao ◽  
Congxiao He ◽  
Xiang Hao ◽  
Cuifang Kuang ◽  
Xu Liu

Numerous advances have been made in X-ray technology in recent years. X-ray imaging plays an important role in the nondestructive exploration of the internal structures of objects. However, the contrast of X-ray absorption images remains low, especially for materials with low atomic numbers, such as biological samples. X-ray phase-contrast images have an intrinsically higher contrast than absorption images. In this review, the principles, milestones, and recent progress of X-ray phase-contrast imaging methods are demonstrated. In addition, prospective applications are presented.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
F. Barbato ◽  
S. Atzeni ◽  
D. Batani ◽  
D. Bleiner ◽  
G. Boutoux ◽  
...  

AbstractX-ray phase contrast imaging (XPCI) is more sensitive to density variations than X-ray absorption radiography, which is a crucial advantage when imaging weakly-absorbing, low-Z materials, or steep density gradients in matter under extreme conditions. Here, we describe the application of a polychromatic X-ray laser-plasma source (duration ~0.5 ps, photon energy >1 keV) to the study of a laser-driven shock travelling in plastic material. The XPCI technique allows for a clear identification of the shock front as well as of small-scale features present during the interaction. Quantitative analysis of the compressed object is achieved using a density map reconstructed from the experimental data.


Author(s):  
Daniel H. Morse ◽  
Arlyn J. Antolak ◽  
Bernice E. Mills

X-ray radiography has long been recognized as a valuable tool for detecting internal features and flaws. Recent developments in microfabrication and composite materials have extended inspection requirements to the resolution limits of conventional radiography. Our work has been directed toward pushing both detection and measurement capabilities to a smaller scale. Until recently, we have used conventional contact radiography, optimized to resolve small features. With the recent purchase of a nano-focus (sub-micron) x-ray source, we are now investigating projection radiography, phase contrast imaging and micro-computed tomography (μ-CT). Projection radiography produces a magnified image that is limited in spatial resolution mainly by the source size, not by film grain size or detector pixel size. Under certain conditions phase contrast can increase the ability to resolve small features such as cracks, especially in materials with low absorption contrast. Micro-computed tomography can provide three-dimensional measurements on a micron scale and has been shown to provide better sensitivity than simple radiographs. We have included applications of these techniques to small-scale measurements not easily made by mechanical or optical means. Examples include void detection in meso-scale nickel MEMS parts, measurement of edge profiles in thick gold lithography masks, and characterization of the distribution of phases in composite materials. Our work, so far, has been limited to film.


2011 ◽  
Vol 5 (1) ◽  
pp. 19-25 ◽  
Author(s):  
Lu Zhang ◽  
Shuqian Luo

The current imaging methods have a limited ability to visualize microstructures of biological soft tissues. Small lesions cannot be detected at the early stage of the disease. Phase contrast imaging (PCI) is a novel non-invasive imaging technique that can provide high contrast images of soft tissues by the use of X-ray phase shift. It is a new choice in terms of non-invasively revealing soft tissue details. In this study, the lung and hepatic fibrosis models of mice and rats were used to investigate the ability of PCI in microstructures observation of soft tissues. Our results demonstrated that different liver fibrosis stages could be distinguished non-invasively by PCI. The three-dimensional morphology of a segment of blood vessel was constructed. Noteworthy, the blood clot inside the vessel was visualized in three dimensions which provided a precise description of vessel stenosis. Furthermore, the whole lung airways including the alveoli were obtained. We had specifically highlighted its use in the visualization and assessment of the alveoli. To our knowledge, this was the first time for non-invasive alveoli imaging using PCI. This finding may offer a new perspective on the diagnosis of respiratory disease. All the results confirmed that PCI will be a valuable tool in biological soft tissues imaging.


2013 ◽  
Vol 24 (1) ◽  
pp. 015007 ◽  
Author(s):  
Yaohu Lei ◽  
Yang Du ◽  
Ji Li ◽  
Zhigang Zhao ◽  
Xin Liu ◽  
...  

2020 ◽  
Vol 64 (2) ◽  
pp. 20503-1-20503-5
Author(s):  
Faiz Wali ◽  
Shenghao Wang ◽  
Ji Li ◽  
Jianheng Huang ◽  
Yaohu Lei ◽  
...  

Abstract Grating-based x-ray phase-contrast imaging has the potential to enhance image quality and provide inner structure details non-destructively. In this work, using grating-based x-ray phase-contrast imaging system and employing integrating-bucket method, the quantitative expressions of signal-to-noise ratios due to photon statistics and mechanical error are analyzed in detail. Photon statistical noise and mechanical error are the main sources affecting the image noise in x-ray grating interferometry. Integrating-bucket method is a new phase extraction method translated to x-ray grating interferometry; hence, its image quality analysis would be of great importance to get high-quality phase image. The authors’ conclusions provide an alternate method to get high-quality refraction signal using grating interferometer, and hence increases applicability of grating interferometry in preclinical and clinical usage.


Sign in / Sign up

Export Citation Format

Share Document