Probabilistic and Statistical Method Application for Electric Power Losses Calculation

Author(s):  
Nadezhda A. Korheeva ◽  
Anatoly V. Lykin ◽  
Lola Sh Atabaeva
2019 ◽  
Vol 2 (2) ◽  
pp. 29-35
Author(s):  
C. Agbeboaye ◽  
F. O. Akpojedje ◽  
B. I. Ogbe

The issue of erratic and epileptic power supply in Nigeria Electricity Company is as old as the country itself. This is not unconnected to some factors such as: inadequate power generated in the national grid, electric power losses in the distribution network, government instability and unstable power reform policies, to mention but a few. The effects of erratic and epileptic power supply have been a major challenge to every sector in Nigeria especially the telecommunication industry. The telecommunication industry plays a significant role in the growth and development of every nation. Hence, this paper aims at critically investigating the causes and effects of erratic and epileptic electric power supply in Nigerian telecommunication industry. More so, the paper suggested and recommended ways to curb and enhance the current erratic and epileptic power situation in the country in order to boost the productivity of telecommunication industry and other sectors as well.


The article dwells upon optimizing, reduction of losses in, and improving the stability of grids by implementing devices that affect the parameters and power flows in a grid. State-of-the-art technology for better control is crucial for the development of electric power systems. FACTS technologies or flexible alternating current transmission systems, essentially transform the grid from a passive electricity transport into a device that actively controls the grid parameters. The article analyzes the development of a 500/220/110 kV grid that uses parameter-affective devices: SVC, BSK, LCD. Steady-state parameters, active power losses, and electric power losses were calculated for a year before and after the devices were deployed. Each device was therefore analyzed for effectiveness. The parameters of the SVC-equipped 500/220/110 kV grid were calculated for emergency operation with the 500 kV line being offline. Thus, the paper also analyzes the emergency performance of the SVC.


2021 ◽  
pp. 51-56
Author(s):  
NATALIA VIKTOROVNA SAVINA ◽  
◽  
VLADIMIR ALEXANDROVICH GAMOLIN ◽  
LARISA ANATOLIEVNA MYASOEDOVA ◽  
◽  
...  

Given the ever-increasing cost of electrical energy, minimizing of power losses is one of the main tasks for the electric grid systems. In this paper, we consider the features of intellectualization of electricity metering and the effect of the introduction of smart metering systems in terms of reduction of power losses.


Vestnik MEI ◽  
2021 ◽  
Vol 3 (3) ◽  
pp. 11-18
Author(s):  
Nailia Sh. Chemborisova ◽  
◽  
Ivan D. Chernenkov ◽  

The problem of selecting the electric power system control nodes is studied. By performing control of these modes, matters concerned with providing reliable power supply of the required quality to consumers can be settled in the most efficient manner. As an example, a fragment of the electric power system mathematical model used in the Finist mode-setting simulator for a power system dispatch control center operator is considered, which represents a highly branched electrical network consisting of eleven 110 kV nodes, three 220 kV nodes connected with the system, and two generator nodes. A new procedure for selecting the control nodes is proposed, which takes into account a combination of different indicators having different measurement units, dimensions and scales is proposed. These indicators characterize the following properties of power system nodes: the reactive power fraction absorbed at a node, the sensitivity of voltage to reactive load variations, the number of connected power lines, and statistical indicators characterizing the change of voltage at the nodes and reactive power flows for different options of installing the reactive power compensation devices. For combined use of these indicators, they were ranked according to the efficiency of installing reactive power compensation devices in the system. For each indicator, a scale of five ranks (intervals) is set, which determine the preferences (qualitative judgments) of the researcher in evaluating the reactive power compensation devices installation efficiency at the system nodes. The highest rank (5) corresponds to the maximum efficiency, and the lowest rank (1) corresponds to the minimum efficiency. To calculate the individual (integral) priority indicator of installing reactive power compensation devices, the ranks of indicators are added together, and their sum is divided by the product of the number of ranks by the number of the used indicators (features). Based on the calculation results, the rating (location) of each node is determined, and the nodes for installing the reactive power compensation devices are selected according to their effect on ensuring the electric power system operation reliability, active power losses in the network, and voltage regulation. Thus, a new procedure is presented for determining the integral indicators for comprehensively estimating the properties of complex electric power system nodes and selecting the controlled nodes using a system of various indicators. These indicators characterize the studied nodes in terms of the efficiency of installing reactive power compensation devices to reduce active power losses in the network, voltage regulation, and ensuring the electric power system operational reliability. The validity of the results obtained in the study is confirmed by their comparison with the indicators of the balance-conductivity method, which has proven itself in solving problems connected with determining the nodes for controlling electric power system operation modes.


2019 ◽  
Vol 124 ◽  
pp. 02013 ◽  
Author(s):  
D. D. Micu ◽  
I. V. Ivshin ◽  
E. I. Gracheva ◽  
O. V. Naumov ◽  
A. N. Gorlov

This paper presents calculation of resistance of tightening contact joints of switching devices. It allows considering the technical condition of low-voltage switching equipment and to specify energy emitted in the switching device in the mode of electrical networks operation is presented in the article.


2018 ◽  
Vol 239 ◽  
pp. 01035 ◽  
Author(s):  
Stanislav Istomin ◽  
Artem Perestenko ◽  
Cong Dang

The paper considers the issue of organization of control of electric power consumption by electric rolling stock by visualizing information on the monitor of the driver's console. With the correct analysis of information coming on board of the electric rolling stock, the train driver makes correction of the driving modes of the train in terms of energy efficiency. In this paper, to visualize information on the efficiency of power consumption by an electric rolling stock on the route, the authors propose using an indicator diagram using a green, white, and orange gradient. The variant of output of the final information on the efficiency of power consumption of electrical energy by an electric rolling stock both within the distances operated by the locomotive crews and within the hauls to the monitor of the driver's console is presented. One of the main advantages of using the technology of visual control of electric power consumption by electric rolling stock is the promptness of correction of decision-making on the rational use of energy resources, the identification of objective reasons for the overspending of energy, and the identification of reference results for the driving of trains. The prospect of development of the research topic is the approbation and implementation of the proposed technical and technological solutions in the production, which will reduce the specific consumption and unproductive electric power losses within the boundaries of the railway accounting zones.