Fractionation characteristic evaluation in a squeezing-electric-field-type cell sorter

Author(s):  
Sena Hasegawa ◽  
Tsutomu Takahashi ◽  
Seiichi Suzuki
2004 ◽  
Vol 383 (3-4) ◽  
pp. 235-239 ◽  
Author(s):  
M. Senthil Kumar ◽  
T.H. Kim ◽  
S.H. Lee ◽  
S.M. Song ◽  
J.W. Yang ◽  
...  

2014 ◽  
Vol 635-637 ◽  
pp. 755-759
Author(s):  
Fang Yan Zheng ◽  
Zi Ran Chen ◽  
Zhi Cheng Yu

Signal processing circuits are proposed for the electric field type time grating sensors. The proposed design scheme integrates sampling function and processing function into a signal field programmable gate array (FPGA) based on system on programmable chip (SOPC) technology. Employing NiosII technology and adding self-defined instructions improve data processing speed for time grating sensors. The proposed signal processing circuits are simple and stabile. The proposed signal processing circuits are applied to electric field type linear time grating sensors, the experiments results that the peak-to peak measuring error is 0.3um within 200mm without any corrections.


Author(s):  
G. F. Rempfer

In photoelectron microscopy (PEM), also called photoemission electron microscopy (PEEM), the image is formed by electrons which have been liberated from the specimen by ultraviolet light. The electrons are accelerated by an electric field before being imaged by an electron lens system. The specimen is supported on a planar electrode (or the electrode itself may be the specimen), and the accelerating field is applied between the specimen, which serves as the cathode, and an anode. The accelerating field is essentially uniform except for microfields near the surface of the specimen and a diverging field near the anode aperture. The uniform field forms a virtual image of the specimen (virtual specimen) at unit lateral magnification, approximately twice as far from the anode as is the specimen. The diverging field at the anode aperture in turn forms a virtual image of the virtual specimen at magnification 2/3, at a distance from the anode of 4/3 the specimen distance. This demagnified virtual image is the object for the objective stage of the lens system.


Author(s):  
Patrick P. Camus

The theory of field ion emission is the study of electron tunneling probability enhanced by the application of a high electric field. At subnanometer distances and kilovolt potentials, the probability of tunneling of electrons increases markedly. Field ionization of gas atoms produce atomic resolution images of the surface of the specimen, while field evaporation of surface atoms sections the specimen. Details of emission theory may be found in monographs.Field ionization (FI) is the phenomena whereby an electric field assists in the ionization of gas atoms via tunneling. The tunneling probability is a maximum at a critical distance above the surface,xc, Fig. 1. Energy is required to ionize the gas atom at xc, I, but at a value reduced by the appliedelectric field, xcFe, while energy is recovered by placing the electron in the specimen, φ. The highest ionization probability occurs for those regions on the specimen that have the highest local electric field. Those atoms which protrude from the average surfacehave the smallest radius of curvature, the highest field and therefore produce the highest ionizationprobability and brightest spots on the imaging screen, Fig. 2. This technique is called field ion microscopy (FIM).


Sign in / Sign up

Export Citation Format

Share Document