Large-Scale Calculations of Low-Frequency Induced Currents in High-Resolution Human Body Models.

Author(s):  
A. Barchanski ◽  
M. Clemens ◽  
E. Gjonaj ◽  
H. De Gersem ◽  
T. Weiland
2007 ◽  
Vol 43 (4) ◽  
pp. 1693-1696 ◽  
Author(s):  
Andreas Barchanski ◽  
Markus Clemens ◽  
Erion Gjonaj ◽  
Herbert De Gersem ◽  
Thomas Weiland

Author(s):  
Changmiao Hu ◽  
Ping Tang

In recent years, China's demand for satellite remote sensing images increased. Thus, the country launched a series of satellites equipped with high-resolution sensors. The resolutions of these satellites range from 30 m to a few meters, and the spectral range covers the visible to the near-infrared band. These satellite images are mainly used for environmental monitoring, mapping, land surface classification and other fields. However, haze is an important factor that often affects image quality. Thus, dehazing technology is becoming a critical step in high-resolution remote sensing image processing. This paper presents a rapid algorithm for dehazing based on a semi-physical haze model. Large-scale median filtering technique is used to extract large areas of bright, low-frequency information from images to estimate the distribution and thickness of the haze. Four images from different satellites are used for experiment. Results show that the algorithm is valid, fast, and suitable for the rapid dehazing of numerous large-sized high-resolution remote sensing images in engineering applications.


Author(s):  
Jangyong Ahn ◽  
Seon-Eui Hong ◽  
Haerim Kim ◽  
Kyunghwan Song ◽  
Hyung-Do Choi ◽  
...  

The concept of a coupling factor was introduced in International Electrotechnical Commission (IEC) 62311 and 62233 to provide a product safety assessment that considers the localized exposure when an electromagnetic field (EMF) source is close to the human body. To calculate the coupling factors between the human body and EMF source, a numerical calculation should be carried out to calculate the internal quantities of the human body models. However, at frequencies below 10 MHz, the computed current density or internal electric field has computational artifacts from segmentation or discretization errors. Specifically, coupling factors are calculated based on the maximum values, which may include computational artifacts due to abnormal peaks. In this study, we propose an improved calculation method to remove computational artifacts by applying the 99.99th percentile in calculating the coupling factors without underestimation. The performance of the proposed method is verified through a comparison based on various human body models with wireless power transfer (WPT) systems and compliance with the reference levels and basic restrictions. The results indicate that the proposed method can provide uniform coupling factors by reducing the computational errors by up to 65.3% compared to a conventional method.


Author(s):  
P. A. Marsh ◽  
T. Mullens ◽  
D. Price

It is possible to exceed the guaranteed resolution on most electron microscopes by careful attention to microscope parameters essential for high resolution work. While our experience is related to a Philips EM-200, we hope that some of these comments will apply to all electron microscopes.The first considerations are vibration and magnetic fields. These are usually measured at the pre-installation survey and must be within specifications. It has been our experience, however, that these factors can be greatly influenced by the new facilities and therefore must be rechecked after the installation is completed. The relationship between the resolving power of an EM-200 and the maximum tolerable low frequency interference fields in milli-Oerstedt is 10 Å - 1.9, 8 Å - 1.4, 6 Å - 0.8.


2020 ◽  
Vol E103.C (11) ◽  
pp. 588-596
Author(s):  
Masamune NOMURA ◽  
Yuki NAKAMURA ◽  
Hiroo TARAO ◽  
Amane TAKEI

2014 ◽  
Vol 31 (2) ◽  
Author(s):  
Mariela Gabioux ◽  
Vladimir Santos da Costa ◽  
Joao Marcos Azevedo Correia de Souza ◽  
Bruna Faria de Oliveira ◽  
Afonso De Moraes Paiva

Results of the basic model configuration of the REMO project, a Brazilian approach towards operational oceanography, are discussed. This configuration consists basically of a high-resolution eddy-resolving, 1/12 degree model for the Metarea V, nested in a medium-resolution eddy-permitting, 1/4 degree model of the Atlantic Ocean. These simulations performed with HYCOM model, aim for: a) creating a basic set-up for implementation of assimilation techniques leading to ocean prediction; b) the development of hydrodynamics bases for environmental studies; c) providing boundary conditions for regional domains with increased resolution. The 1/4 degree simulation was able to simulate realistic equatorial and south Atlantic large scale circulation, both the wind-driven and the thermohaline components. The high resolution simulation was able to generate mesoscale and represent well the variability pattern within the Metarea V domain. The BC mean transport values were well represented in the southwestern region (between Vitória-Trinidade sea mount and 29S), in contrast to higher latitudes (higher than 30S) where it was slightly underestimated. Important issues for the simulation of the South Atlantic with high resolution are discussed, like the ideal place for boundaries, improvements in the bathymetric representation and the control of bias SST, by the introducing of a small surface relaxation. In order to make a preliminary assessment of the model behavior when submitted to data assimilation, the Cooper & Haines (1996) method was used to extrapolate SSH anomalies fields to deeper layers every 7 days, with encouraging results.


Sign in / Sign up

Export Citation Format

Share Document