$W_{e}=100\mathrm{nm}$ InP/lnGaAs DHBT with Self-aligned MOCVD Regrown p-GaAs Extrinsic Base Exhibiting $1\Omega-\mu\mathrm{m}^{2}$ Base Contact Resistivity

Author(s):  
Yihao Fang ◽  
Hsin-Ying Tseng ◽  
Mark J.W. Rodwell
Author(s):  
Rose Emergo ◽  
Steve Brockett ◽  
Pat Hamilton

Abstract A single power amplifier-duplexer device was submitted by a customer for analysis. The device was initially considered passing when tested against the production test. However, further electrical testing suggested that the device was stuck in a single power mode for a particular frequency band at cold temperatures only. This paper outlines the systematic isolation of a parasitic Schottky diode formed by a base contactcollector punch through process defect that pulled down the input of a NOR gate leading to the incorrect logic state. Note that this parasitic Schottky diode is parallel to the basecollector junction. It was observed that the logic failure only manifested at colder temperatures because the base contact only slightly diffused into the collector layer. Since the difference in the turn-on voltages between the base-collector junction and the parasitic Schottky diode increases with decreasing temperature, the effect of the parasitic diode is only noticeable at lower temperatures.


1984 ◽  
Vol 20 (22) ◽  
pp. 944 ◽  
Author(s):  
S.S. Gill ◽  
J.R. Dawsey ◽  
A.G. Cullis
Keyword(s):  

2021 ◽  
Vol 13 (6) ◽  
pp. 7317-7323
Author(s):  
Zhenyi Wang ◽  
Chenguang Fu ◽  
Kaiyang Xia ◽  
Feng Liu ◽  
Xinbing Zhao ◽  
...  

2012 ◽  
Vol 49 (11) ◽  
pp. 1267-1284 ◽  
Author(s):  
Olajide Samuel Oshati ◽  
Arun J. Valsangkar ◽  
Allison B. Schriver

Earth pressure data from the field instrumentation of a cast-in-place reinforced rectangular box culvert are presented in this paper. The instrumented culvert is a 2.60 m by 3.60 m double-cell reinforced cast-in-place rectangular box buried under 25.10 m of fill constructed using the induced trench installation (ITI) method. The average earth pressure measured across the roof was 0.42 times the overburden pressure, and an average of 0.52 times the overburden pressure was measured at mid-height of the culvert on the sidewalls. Base contact pressure under the rectangular box culvert was also measured, providing field-based data demonstrating increased base pressure resulting from downward drag forces developed along the sidewalls of the box culvert. An average increase of 25% from the measured vertical earth pressures on the roof plus the culvert dead load (DL) pressure was calculated at the culvert base. A model culvert was also tested in a geotechnical centrifuge to obtain data on earth pressures at the top, sides, and base of the culvert. The data from the centrifuge testing were compared with the prototype structure, and the centrifuge test results agreed closely with the measured field prototype pressures, in spite of the fact that full similitude was not attempted in centrifuge testing.


Sign in / Sign up

Export Citation Format

Share Document