Grid-connected Inverter Impedance Estimation Considering Grid Impedance and Frequency Coupling in the Stationary Frame

Author(s):  
Junliang Liu ◽  
Xiong Du ◽  
Ying Shi ◽  
Heng-Ming Tai
2014 ◽  
Vol 986-987 ◽  
pp. 1169-1172
Author(s):  
Ping Wang ◽  
Meng Meng Cai

The LCL filter is widely applied as interface between grid-connected inverter and grid due to the preferable high frequency attenuation characteristic. Under the condition of weak grid, impedance value of grid model cannot be ignored, the existence of grid impedance results in different LCL resonant frequencies, which will arise challenges of traditional active damping control. Based on the analysis of band pass filter using active damping control strategy, an adaptive active damping control is proposed in this paper by introducing the application of active notch filter, which can adjust the position of negative resonance point adaptively so as to manage sudden grid changes. Theoretical analysis and simulation results presented on the platform of grid-connected PV inverter system indicate the effectiveness and adaptability of this active damping strategy.


2021 ◽  
Vol 233 ◽  
pp. 01080
Author(s):  
Xu Hao Hao ◽  
Wang Fang ◽  
Liang Zhi Cheng

When the power grid impedance mutates, the output power of the grid-connected photovoltaic power generation system controlled by drooping will become very unstable. To solve this problem, an improved droop control algorithm based on network impedance detection is proposed. Taking photovoltaic grid-connected power generation system as the research object, the influence of power grid impedance on traditional droop control is firstly expounded by introducing power grid impedance value into traditional droop control. Then the method of real-time network impedance extraction is introduced. Furthermore, according to the bandwidth and phase angle constraints of the equivalent output impedance phase frequency characteristics of the photovoltaic grid-connected inverter, the controller parameters are updated in real time to achieve the purpose of adaptive network impedance mutation. Finally, the proposed method is tested and verified by real-time simulation in the loop respectively. The results show that the proposed method is correct.


Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3676
Author(s):  
Chuanyue Li ◽  
Taoufik Qoria ◽  
Frederic Colas ◽  
Jun Liang ◽  
Wenlong Ming ◽  
...  

The dq impedance stability analysis for a grid-connected current-control inverter is based on the impedance ratio matrix. However, the coupled matrix brings difficulties in deriving its eigenvalues for the analysis based on the general Nyquist criterion. If the couplings are ignored for simplification, unacceptable errors will be present in the analysis. In this paper, the influence of the couplings on the dq impedance stability analysis is studied. To take the couplings into account simply, the determinant-based impedance stability analysis is used. The mechanism between the determinant of the impedance-ratio matrix and the inverter stability is unveiled. Compared to the eigenvalues-based analysis, only one determinant rather than two eigenvalue s-function is required for the stability analysis. One Nyquist plot or pole map can be applied to the determinant to check the right-half-plane poles. The accuracy of the determinant-based stability analysis is also checked by comparing with the state-space stability analysis method. For the stability analysis, the coupling influence on the current control, the phase-locked loop, and the grid impedance are studied. The errors can be 10% in the stability analysis if the couplings are ignored.


Energies ◽  
2018 ◽  
Vol 11 (1) ◽  
pp. 57 ◽  
Author(s):  
Yingjie Wang ◽  
Jiashi Wang ◽  
Wei Zeng ◽  
Haiyuan Liu ◽  
Yushuo Chai

2016 ◽  
Vol 1 (4) ◽  
pp. 50
Author(s):  
Jiao Jiao ◽  
R. Mark Nelms

Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.