Analysis of experimental rapid power transfer and fault performance in DC naval power systems

Author(s):  
M. Steurer ◽  
M. Bosworth ◽  
D. Soto ◽  
S. D. Sudhoff ◽  
S. D. Pekarek ◽  
...  
Author(s):  
Diego A. Monroy-Ortiz ◽  
Sergio A. Dorado-Rojas ◽  
Eduardo Mojica-Nava ◽  
Sergio Rivera

Abstract This article presents a comparison between two different methods to perform model reduction of an Electrical Power System (EPS). The first is the well-known Kron Reduction Method (KRM) that is used to remove the interior nodes (also known as internal, passive, or load nodes) of an EPS. This method computes the Schur complement of the primitive admittance matrix of an EPS to obtain a reduced model that preserves the information of the system as seen from to the generation nodes. Since the primitive admittance matrix is equivalent to the Laplacian of a graph that represents the interconnections between the nodes of an EPS, this procedure is also significant from the perspective of graph theory. On the other hand, the second procedure based on Power Transfer Distribution Factors (PTDF) uses approximations of DC power flows to define regions to be reduced within the system. In this study, both techniques were applied to obtain reduced-order models of two test beds: a 14-node IEEE system and the Colombian power system (1116 buses), in order to test scalability. In analyzing the reduction of the test beds, the characteristics of each method were classified and compiled in order to know its advantages depending on the type of application. Finally, it was found that the PTDF technique is more robust in terms of the definition of power transfer in congestion zones, while the KRM method may be more accurate.


Sensors ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 2052
Author(s):  
Milena Kurzawa ◽  
Cezary Jędryczka ◽  
Rafał M. Wojciechowski

In this paper, the feasibility of applying a multi-branch equivalent model employing first- and second-order Cauer circuits for the analysis of electromagnetic transducers used in systems of wireless power transfer is discussed. A method of formulating an equivalent model (EqM) is presented, and an example is shown for a wireless power transfer system (WPTS) consisting of an air transformer with field concentrators. A method is proposed to synthesize the EqM of the considered transducer based on the time-harmonic field model, an optimization algorithm employing the evolution strategy (ES) and the equivalent Cauer circuits. A comparative analysis of the performance of the considered WPTS under high-frequency voltage supply calculated using the proposed EqM and a 3D field model in the time domain using the finite element method (FEM) was carried out. The selected results of the conducted analysis are presented and discussed.


2019 ◽  
Vol 9 (18) ◽  
pp. 3769
Author(s):  
Yi-Hung Liao ◽  
Yue Lin

This paper presents a bidirectional wireless power transfer system for mobile power applications. A novel 2-switch bidirectional wireless power transfer system with dual-side control is proposed for mobile power applications. Although only two switches are adopted, the energy can be transferred from the transmitter side to the receiver side and vice versa. The term bidirectional means that the power-flow is bidirectional and also that the transmitter is also a receiver and the receiver is also a transmitter. The output energy can be easily controlled by the duty ratios of the two switches. Thus, the proposed bidirectional power transfer system uses only one circuit to achieve bidirectional power transfer. Hence, the system cost and volume can be reduced so that the system is small and convenient for mobile power systems, portable and/or wearable electronic devices. A prototype system is constructed and the experimental results verify the validity of the proposed bidirectional wireless power transfer system.


2019 ◽  
Vol 9 (14) ◽  
pp. 2813 ◽  
Author(s):  
Sayed Mir Shah Danish ◽  
Ryuto Shigenobu ◽  
Mitsunaga Kinjo ◽  
Paras Mandal ◽  
Narayanan Krishna ◽  
...  

A number of studies realized operation of power systems are unstable in developing countries due to misconfiguration of distribution systems, limited power transfer capability, inconsistency of renewable resources integration, paucity of control and protection measures, timeworn technologies, and disproportionately topology. This study underlines an Afghanistan case study with 40% power losses that is mainly pertinent from old distribution systems. The long length of distribution systems, low-power transfer capability, insufficient control and protection strategy, peak-demand elimination, and unstable operation (low energy quality and excessive voltage deviations) are perceived pre-eminent challenges of Afghanistan distribution systems. Some attainable solutions that fit challenges are remodeling (network reduction), networks reinforcement, optimum compensation strategy, reconfiguration options, improving, and transfer capability. This paper attempts to propose a viable solution using multiobjective optimization method of auto-tap-changer pole transformer (ATCTr). The proposed methodology in terms of optimal numbers and placement of ATCTr can be known as a novel two-dimensional solution. For this purpose, a real case of Kabul City distribution system is evaluated. Simulation results indicate the effectiveness of the proposed method in reducing system losses and improving system overall performance. This approach tends to regulate the voltage deviation in a proper and statutory range with minimum number and optimum placement of ATCTrs. The proposed method is simulated using MATLAB® environment to compare and evaluate performance of the proposed network under different situations and scenarios.


Energies ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 6663
Author(s):  
Bae-Geun Lee ◽  
Joonwoo Lee ◽  
Soobae Kim

This paper presents a static network equivalent model for Korean power systems. The proposed equivalent model preserves the overall transmission network characteristics focusing on power flows among areas in Korean power systems. For developing the model, a power transfer distribution factor (PTDF)-based k-means++ algorithm was used to cluster the bus groups in which similar PTDF characteristics were identified. For the reduction process, the bus groups were replaced by a single bus with a generator or load, and an equivalent transmission line was determined to maintain power flows in the original system model. Appropriate voltage levels were selected, and compensation for real power line losses was made for the correct representation. A Korean power system with more than 1600 buses was reduced to a 38-bus system with 13 generators, 25 loads, and 74 transmission lines. The effectiveness of the developed equivalent model was evaluated by performing power flow simulations and comparisons of various characteristics of the original and reduced systems. The simulation comparisons show that the developed equivalent model maintains inter-area power flows as close as possible to the original Korean power systems.