scholarly journals A Real Distribution Network Voltage Regulation Incorporating Auto-Tap-Changer Pole Transformer Multiobjective Optimization

2019 ◽  
Vol 9 (14) ◽  
pp. 2813 ◽  
Author(s):  
Sayed Mir Shah Danish ◽  
Ryuto Shigenobu ◽  
Mitsunaga Kinjo ◽  
Paras Mandal ◽  
Narayanan Krishna ◽  
...  

A number of studies realized operation of power systems are unstable in developing countries due to misconfiguration of distribution systems, limited power transfer capability, inconsistency of renewable resources integration, paucity of control and protection measures, timeworn technologies, and disproportionately topology. This study underlines an Afghanistan case study with 40% power losses that is mainly pertinent from old distribution systems. The long length of distribution systems, low-power transfer capability, insufficient control and protection strategy, peak-demand elimination, and unstable operation (low energy quality and excessive voltage deviations) are perceived pre-eminent challenges of Afghanistan distribution systems. Some attainable solutions that fit challenges are remodeling (network reduction), networks reinforcement, optimum compensation strategy, reconfiguration options, improving, and transfer capability. This paper attempts to propose a viable solution using multiobjective optimization method of auto-tap-changer pole transformer (ATCTr). The proposed methodology in terms of optimal numbers and placement of ATCTr can be known as a novel two-dimensional solution. For this purpose, a real case of Kabul City distribution system is evaluated. Simulation results indicate the effectiveness of the proposed method in reducing system losses and improving system overall performance. This approach tends to regulate the voltage deviation in a proper and statutory range with minimum number and optimum placement of ATCTrs. The proposed method is simulated using MATLAB® environment to compare and evaluate performance of the proposed network under different situations and scenarios.

Author(s):  
Gunjan Varshney ◽  
Durg S. Chauhan ◽  
Madhukar P. Dave ◽  
Nitin

Background: In modern electrical power distribution systems, Power Quality has become an important concern due to the escalating use of automatic, microprocessor and microcontroller based end user applications. Methods: In this paper, power quality improvement has done using Photovoltaic based Distribution Static Compensator (PV-DSTATCOM). Complete simulation modelling and control of Photovoltaic based Distribution Static Compensator have been provided in the presented paper. In this configuration, DSTATCOM is fed by solar photovoltaic array and PV module is also helpful to maintain the DC link voltage. The switching of PV-STATCOM is controlled by Unit template based control theory. Results: The performance of PV-DSTATCOM has been evaluated for Unity Power Factor (UPF) and AC Voltage Control (ACVC) modes. Here, for studying the power quality issues three-phase distribution system is considered and results have been verified through simulation based on MATLAB software. Conclusion: Different power quality issues and their improvement are studied and presented here for harmonic reduction, DC voltage regulation and power factor correction.


Mathematics ◽  
2018 ◽  
Vol 6 (9) ◽  
pp. 158
Author(s):  
Farzaneh Pourahmadi ◽  
Payman Dehghanian

Allocation of the power losses to distributed generators and consumers has been a challenging concern for decades in restructured power systems. This paper proposes a promising approach for loss allocation in power distribution systems based on a cooperative concept of game-theory, named Shapley Value allocation. The proposed solution is a generic approach, applicable to both radial and meshed distribution systems as well as those with high penetration of renewables and DG units. With several different methods for distribution system loss allocation, the suggested method has been shown to be a straight-forward and efficient criterion for performance comparisons. The suggested loss allocation approach is numerically investigated, the results of which are presented for two distribution systems and its performance is compared with those obtained by other methodologies.


Author(s):  
Gaikwad Vikas Subhash ◽  
Swati S. More

Reactive power compensation is an important issue in electric power systems, involving operational, economical and quality of service aspects. Consumer loads (residential, industrial, service sector, etc.) impose active and reactive power demand, depending on their characteristics. This paper presents an efficient method for solving the load flow problem in distribution systems and which is implemented for Pune city (India) to check the validity of proposed method. A simple algebraic matrix equation to solve the load flow problem is derived by using the complex power balance equations. By adopting the rectangular coordinate, which requires the neglect of only second order terms in the linearization procedure, the proposed method gives better convergence characteristics. Newton-Raphsonmethod is the famous load flow calculation technique, and normally used dueto its rapidness of numerical convergence. The proposed method estimates the incremental changesof active power on each generation bus with respect to the total system power loss, efficiency and the estimated value are used to update the slack bus power.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Ying-Yi Hong ◽  
Faa-Jeng Lin ◽  
Fu-Yuan Hsu

The Kyoto protocol recommended that industrialized countries limit their green gas emissions in 2012 to 5.2% below 1990 levels. Photovoltaic (PV) arrays provide clear and sustainable renewable energy to electric power systems. Solar PV arrays can be installed in distribution systems of rural and urban areas, as opposed to wind-turbine generators, which cause noise in surrounding environments. However, a large PV array (several MW) may incur several operation problems, for example, low power quality and reverse power. This work presents a novel method to reconfigure the distribution feeders in order to prevent the injection of reverse power into a substation connected to the transmission level. Moreover, a two-stage algorithm is developed, in which the uncertain bus loads and PV powers are clustered by fuzzy-c-means to gain representative scenarios; optimal reconfiguration is then achieved by a novel mean-variance-based particle swarm optimization. The system loss is minimized while the operational constraints, including reverse power and voltage variation, are satisfied due to the optimal feeder reconfiguration. Simulation results obtained from a 70-bus distribution system with 4 large PV arrays validate the proposed method.


Complexity ◽  
2019 ◽  
Vol 2019 ◽  
pp. 1-13 ◽  
Author(s):  
Yinuo Huang ◽  
Licheng Wang ◽  
Kai Wang

Distributed rooftop photovoltaic (PV) generators prospered distributed generation (DG) in recent years. Certain randomness of rooftop PV connection may lead to significant PV power imbalance across three phases, especially in low-voltage distribution systems. Due to interphase line coupling, traditional Var compensation methods which typically have competent voltage regulation performance may become less effective in such PV imbalance scenarios. In this paper, the limitation of traditional Var compensation methods in voltage regulation with unbalanced PV power integration is demonstrated and comprehensively analyzed. After describing the voltage regulation challenge, based on the voltage sensitivity analysis, it is revealed that PV power unbalanced level together with equivalent mutual impedance among phase conductors has a significant impact on the effectiveness of traditional Var compensation methods on voltage regulation. On this basis, to improve the performance of voltage regulation methods, some suggestions are proposed for both current system operation and future distribution system planning. Numerical studies demonstrate the effectiveness of the proposed suggestions. Future rooftop PV integration in LV systems can benefit from this research.


Author(s):  
Reza Tajik

Nowadays, the utilization of renewable energy resources in distribution systems (DSs) has been rapidly increased. Since distribution generation (DG) use renewable resources (i.e., biomass, wind and solar) are emerging as proper solutions for electricity generation. Regarding the tremendous deployment of DG, common distribution networks are undergoing a transition to DSs, and the common planning methods have become traditional in the high penetration level. Indeed, in conformity with the voltage violation challenge of these resources, this problem must be dealt with too. So, due to the high penetration of DG resources and nonlinear nature of most industrial loads, the planning of DG installation has become an important issue in power systems. The goal of this paper is to determine the planning of DG in distribution systems through smart grid to minimize losses and control grid factors. In this regard, the present work intending to propose a suitable method for the planning of DSs, the key properties of DS planning problem are evaluated from the various aspects, such as the allocation of DGs, and planning, and high-level uncertainties. Also depending on these analyses, this universal literature review addressed the updated study associated with DS planning. In this work, an operational design has been prepared for a higher performance of the power distribution system in the presence of DG. Artificial neural network (ANN) has been used as a method for voltage monitoring and generation output optimization. The findings of the study show that the proposed method can be utilized as a technique to improve the process of the distribution system under various penetration levels and in the presence of DG. Also, the findings revealed that the optimal use of ANN method leads to more controllable and apparent DS.


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 199
Author(s):  
Chengwei Lei ◽  
Weisong Tian

Fused contactors and thermal magnetic circuit breakers are commonly applied protective devices in power distribution systems to protect the circuits when short-circuit faults occur. A power distribution system may contain various makes and models of protective devices, as a result, customizable simulation models for protective devices are demanded to effectively conduct system-level reliable analyses. To build the models, thermal energy-based data analysis methodologies are first applied to the protective devices’ physical properties, based on the manufacturer’s time/current data sheet. The models are further enhanced by integrating probability tools to simulate uncertainties in real-world application facts, for example, fortuity, variance, and failure rate. The customizable models are expected to aid the system-level reliability analysis, especially for the microgrid power systems.


2012 ◽  
Vol 15 (2) ◽  
pp. 17-26
Author(s):  
Loc Dac Ho

A distribution system is one of the most important parts of power systems which show a connection between power plants and loads. Each connection has an economic affection in transferring power from sources to loads. Power companies expect to find out an optimal configuration with great benefits which is the lowest power loss. This paper proposes an application of a genetic algorithm for finding out an optimal configuration which has the lowest power loss with constrains such as: unisolated loads, limited powers in lines and transformers and lowest voltage drops. The effectiveness of the proposal is confirmed through simulation results on power systems [3] as well as comparisons with other results of [1], [3], [6], [8]


Author(s):  
V. Lakshmi Devi ◽  
T. Phanindra

Electrical distribution system suffers from various problems like reactive power burden, unbalanced loading, voltage regulation and harmonic distortion. Though DSTATCOMS are ideal solutions for such systems, they are not popular because of the cost and complexity of control involved. Phase wise balanced reactive power compensations are required for fast changing loads needing dynamic power factor correcting devices leading to terminal voltage stabilization. Static Var Compensators (SVCs) remain ideal choice for such loads in practice due to low cost and simple control strategy. These SVCs, while correcting power factor, inject harmonics into the lines causing serious concerns about quality of the distribution line supplies at PCC. This paper proposes to minimize the harmonics injected into the distribution systems by the operation of TSC-TCR type SVC used in conjunction with fast changing loads at LV distribution level. Fuzzy logic system and ANN are going to be used solve this nonlinear problem, giving optimum triggering delay angles used to trigger switches in TCR. The scheme with Artificial Neural Network (ANN) is attractive and can be used at distribution level where load harmonics are within limits. Verification of the system and by using mat lab / simulink with proper modeling.


IJOSTHE ◽  
2017 ◽  
Vol 4 (3) ◽  
pp. 6 ◽  
Author(s):  
Sarika Gautami ◽  
Rajeev Tiwari

Photovoltaic power generation refers to the use of solar photovoltaic cells to the solar radiation can be directly transformed into electricity generation. Distributed photovoltaic power generation, refers to the construction in the vicinity of the user's location, the operation mode to the user side of spontaneous self-occupied mainly, the excess power on the Internet, and in the distribution system to balance the characteristics of the photovoltaic power generation facilities. Distributed photovoltaic power generation follow the principle of local conditions, clean and efficient, decentralized layout, the principle of the nearest use, and make full use of local solar energy resources, alternative and reduce fossil energy consumption. This paper aims to investigate and emphasize the importance of the grid-connected PV system. The investigation was conducted to critically review the literature on expected potential problems associated with issues of PV based grid system. The main purpose of this paper is to discuss the basic understanding of photovoltaic (PV) based distributed generation power system and how these power flows will influence the performance and stability of a power system. Some of the PV grid integration issues such as voltage regulation, voltage sags, harmonic distortion, etc are also discussed and possible solutions are also mentioned.


Sign in / Sign up

Export Citation Format

Share Document