Acceleration Reliability Tests for Lead-free Solder Joints under Thermal Cycling Coupling with Current Stressing

Author(s):  
Hongbo Xu ◽  
Shuai Zhang ◽  
Hongyun Zhao ◽  
Mingyu Li
Author(s):  
N. Islam ◽  
J. C. Suhling ◽  
P. Lall ◽  
T. Shete ◽  
H. S. Gale ◽  
...  

In this study, we have examined the thermal cycling reliability of several lead free chip resistor solder joint configurations. Five sizes of resistors (2512, 1206, 0805, 0603, 0402), 2 temperature ranges (−40 to 125°C and −40 to 150°C), and five different solder types have been examined. The solders include the normal SnAgCu alloy recommended by earlier studies (95.5Sn-3.8Ag-0.7Cu), and several variations that include small percentages of Bismuth and Indium to enhance fatigue resistance. Results have been compared to data for standard 63Sn-37Pb joints.


2013 ◽  
Vol 634-638 ◽  
pp. 2800-2803 ◽  
Author(s):  
Li Meng Yin ◽  
Yan Fei Geng ◽  
Zhang Liang Xu ◽  
Song Wei

Adopting an accurate micro-tensile method based on dynamic mechanical analyzer (DMA) instrument, the tensile strength of three kinds of copper-wire/solder/copper-wire sandwich structured microscale lead-free solder joints that underwent current stressing with a direct current density of 1.0×104 A/cm2 and loading time of 48 hours were investigated, and compared with those solder joints isothermal aged at 100 0C for 48 hours and as-reflowed condition. These three kinds of microscale columnar solder joints have different volumes, i.e., a same diameter of 300 μm but different heights of 100 μm, 200 μm and 300 μm. Experimental results show that both current stressing and isothermal aging degrades the tensile strength of microscale solder joints, and the solder joint with smaller volume obtains higher tensile strength under same test condition. In addition, current stressing induces obvious electromigration (EM) issue under high current density of 1.0×104 A/cm2, resulting in the decreasing of tensile strength and different fracture position, mode and surface morphology of microscale solder joints. The degree of strength degradation increases with the increasing of joint height when keep joint diameter constant, this is mainly due to that electromigration leads to voids form and grow at the interface of cathode, and solder joints with larger volume may contains more soldering defects as well.


2006 ◽  
Vol 20 (25n27) ◽  
pp. 4553-4558
Author(s):  
OUK SUB LEE ◽  
NO HOON MYOUNG ◽  
DONG HYEOK KIM ◽  
MAN JAE HUR ◽  
SI WOON HWANG

The use of BGA (Ball Grid Array) interconnects utilizing the lead-free solder joint has grown rapidly because of its small volume and diversity of application. Thus, it requires the continuous quantification and refinement of lead-free solder joint reliability. The lead-free solder creep and cyclically applied mechanical loads cause metal fatigue on the lead-free solder joint which inevitably leads to an electrical discontinuity. In the field application, BGA solder joints experience mechanical loads during temperature changes caused by power up/down events as the result of the CTE (Coefficient of Thermal Expansion) mismatch between the substrate and the Si die. In this paper, extremely small resistance changes at joint area corresponding to through-cracks generated by thermal fatigue were measured. In this way, the failure was defined in terms of anomalous changes in electrical resistance of the joint. Furthermore the reliability of BGA solder joints in thermal cycling is evaluated by using the modified coffin-Manson criterion which may define and distinguish failure. Any change in circuit resistance according to the accumulated damage induced by the thermal cycling in the joint was recorded and evaluated in order to quantitate reliability of solder joint.


Sign in / Sign up

Export Citation Format

Share Document