Computation of electric field distribution near EHV/UHV transmission lines

Author(s):  
B Subba Reddy ◽  
Ziyauddin Khan ◽  
Kartik Bhat ◽  
M Balachandra Hegde
2012 ◽  
Vol 516-517 ◽  
pp. 1517-1520
Author(s):  
Jian Xun Hu ◽  
Gong Da Zhang ◽  
Hong Yu Zhang ◽  
Xiao Qin Zhang

Using the finite element analysis, this work analyzed the electric field distribution of 220kV transmission steel tower with double-circuit and composite material transmission tower with the same size, and compared the electric field effect of two materials transmission tower for surroundings. And this work compared the vertical and axial electric field distribution along transmission line of the two materials transmission tower. The results indicate the composite material tower can improve the environment of electric field near the transmission lines.


2021 ◽  
Vol 6 (1) ◽  
pp. 21-30
Author(s):  
Ragaleela Dalapati Rao ◽  
Padmanabha Raju Chinda ◽  
Meduri Kiran

The performance of insulator strings in transmission lines can be improved by corona rings owing to their electric field grading property. The insulation performance of the string depends on the corona ring parameter settings. In this study, the design of a corona ring for a 400 kV non-ceramic overhead line insulator is presented. Two parameters were altered during the investigation, ring measurement (R) and ring tube breadth (r) while maintaining a constant ring height (h). Based on electric field distribution, the proposed composite insulators were compared with glass insulators. Simulation studies were performed for the insulator strings, including corona rings with different design parameters. The corona discharge and optimal configuration results were analyzed, and it was found that the electric field was lower with composite insulators.


2014 ◽  
Vol 521 ◽  
pp. 321-329
Author(s):  
Quan Zhou ◽  
Li Tu ◽  
Rui Bie ◽  
Dong Feng ◽  
You Ping Fan

Currently, there is little experience about design of the 1-tower-double-circuit DC transmission lines. But the electromagnetic field distribution under its lines is complicated. In order to study the nominal electric field distribution of 1-tower-double-circuit DC transmission lines under different situations and a variety of operating conditions, the currents with analytical solutions are used to simulate the discrete or uneven distributed continuous charge. In the works within an acceptable range, the linear equations are built to solve simulation charge according to the electromagnetic theory. And ground nominal electric field of 1-tower-double-circuit DC transmission lines is calculated. The nominal electric field distribution extreme value extreme under different arrangements and nominal electric field distribution under a variety of operating conditions are analyzed comparatively. In this paper, the results show that the arrangements of lines have effects on the distribution characteristics of nominal electric field in normal condition. When monopole or bipolar or the bipolar of one line doesnt work, the change of nominal electric field is pronounced, but their extremes reduce.