Electric Field Analysis of 220 kV Composite Material Tower Lines

2012 ◽  
Vol 516-517 ◽  
pp. 1517-1520
Author(s):  
Jian Xun Hu ◽  
Gong Da Zhang ◽  
Hong Yu Zhang ◽  
Xiao Qin Zhang

Using the finite element analysis, this work analyzed the electric field distribution of 220kV transmission steel tower with double-circuit and composite material transmission tower with the same size, and compared the electric field effect of two materials transmission tower for surroundings. And this work compared the vertical and axial electric field distribution along transmission line of the two materials transmission tower. The results indicate the composite material tower can improve the environment of electric field near the transmission lines.

2014 ◽  
Vol 521 ◽  
pp. 321-329
Author(s):  
Quan Zhou ◽  
Li Tu ◽  
Rui Bie ◽  
Dong Feng ◽  
You Ping Fan

Currently, there is little experience about design of the 1-tower-double-circuit DC transmission lines. But the electromagnetic field distribution under its lines is complicated. In order to study the nominal electric field distribution of 1-tower-double-circuit DC transmission lines under different situations and a variety of operating conditions, the currents with analytical solutions are used to simulate the discrete or uneven distributed continuous charge. In the works within an acceptable range, the linear equations are built to solve simulation charge according to the electromagnetic theory. And ground nominal electric field of 1-tower-double-circuit DC transmission lines is calculated. The nominal electric field distribution extreme value extreme under different arrangements and nominal electric field distribution under a variety of operating conditions are analyzed comparatively. In this paper, the results show that the arrangements of lines have effects on the distribution characteristics of nominal electric field in normal condition. When monopole or bipolar or the bipolar of one line doesnt work, the change of nominal electric field is pronounced, but their extremes reduce.


Author(s):  
Rahul Krishnan ◽  
Subhajit Samanta ◽  
Sudha R ◽  
K Govardhan

This paper involves designing and applying electric field analysis on multiple long rod insulators. Quality HV insulators are an integral part of power systems because they separate the Transmission lines carrying high voltages from the grounded poles. They must have the ability to withstand both high electrical and mechanical stress. So for this purpose modeling of long rod insulator was done with multiple materials such as ceramic, porcelain, and fiber glass and silicon rubber. Electric field analysis can be used to determine voltage profile of each material which in turn can be used to determine how much electrical stress the material can undertake. An attempt was made to model existing long rod insulator designs using software like Solidworks. Subsequently modifications were made to the design by changing parameters such as diameter of the insulator body, angle made by insulator cups etc. These models were then subjected to electric field analysis using finite element analysis software such as Elecnet or Comsol Multiphysics in order to identify the points where maximum electric field stress exists. Further modifications were made on order to reduce and equalize the electric field over the insulator surface.


2010 ◽  
Vol 43 ◽  
pp. 546-550
Author(s):  
Kang Huang ◽  
Gen Qian ◽  
Qing Song Liang ◽  
Yu Feng Qu

The structure of current micro-machined gyroscope result in detection error and processing difficulty, which can be reduced by redesigning the structure such as a new type researched here to enhance the accuracy..The new structure for gyroscope and the method of driving force calculating for it is introduced in this paper. A 3D micro-machined gyroscope model has been built through CAD software, while finite model through CAE software. Besides, the driving structure has been analyzed to gain the size of driving force and electric-field distribution.


2014 ◽  
Vol 1008-1009 ◽  
pp. 598-602
Author(s):  
Shu Min Sun ◽  
Yan Cheng ◽  
Xin Su

±1000kV DC wall bushing is a complex insulation system working in different conditions, such as DC, AC and polarity reversal. No matter what kind of conditions, the space charge effects on the electric field distribution of the bushing are remarkable. A finite element model for ±1000kV DC wall bushing is established based on space charge theory, to analyze the electric field distribution in different conditions, especially when polarity reversal occurs. The research results provide useful references for the electric field analysis and insulation optimization of UHV (ultra high voltage) DC wall bushings.


2011 ◽  
Vol 291-294 ◽  
pp. 2352-2355
Author(s):  
Cheng Lin Liu ◽  
Ze Sun ◽  
Yun Zhao ◽  
Xing Fu Song ◽  
Gui Min Lu ◽  
...  

The electric field distribution was the main factor affecting on the current efficiency of electrolysis cell. So, the electric field distribution of magnesium electrolysis cell was studied to improve the current efficiency by two of main finite element softwares, COMSOL and ANSYS. The electric field distribution and its trends with the electrolyte change from 1.25m to 1.40m were calculated by using the two softwares. Form the results, the characteristics of COMSOL and ANSYS can be obtained. The conclusions of the paper will provided a significant reference for choose the appropriate software in practice process.


Author(s):  
Tohid Jahangiri ◽  
Claus Leth Bak ◽  
Faria Da Silva ◽  
Brian Endahl

<p>The use of uni-body composite cross-arm in a fully composite-based pylon is a new concept for the next generation of overhead transmission lines. The crossarm is stressed by phase-to-phase voltages except in two regions, which are stressed by phase-to-ground voltages caused by installation of shield wires. Due to a major difference between the novel cross-arm structure and traditional composite cross-arms, the electric field distribution in the uni-body composite cross-arm is of considerable interest. This paper presents and analyses the electric field distribution around and inside the hollow core uni-body cross-arm through which ground cable passes to connect the shield wires. Two different shed profiles are considered on the cross-arm and evaluated based on the guidelines of IEC 60815-3. </p><p>The 2D geometry of pylon is modeled in ANSYS Finite Element Analysis package. The electric field and potential distribution along the pylon is graphically depicted and the effectiveness of assigned shed profiles in controlling the power frequency stresses are investigated in the areas with high field intensities.</p>


2013 ◽  
Vol 347-350 ◽  
pp. 1276-1282
Author(s):  
Yu Ping Teng ◽  
Shao Tao Dai ◽  
Li Ye Xiao ◽  
Dong Zhang ◽  
Bing Song Cheng

The 75 m/1.5 kA AC high-temperature superconducting cable(75 m HTS cable) and the 360 m/10 kA DC HTS power cable (10 kA HTS cable), which are supported by Chinese State 863 projects, are both of the demonstration projects facing to industrialization application. The characteristic in structure of warm dielectric (WD) insulated HTS cable is introduced. The electric field distribution characteristic at the cryogenic envelope body, the end-point of metallic shield layer at the end of the HTS cable and the connection sections are analyzed; the controlling method for electric field stress is introduced; there is serious concentration of electric field both in the termination and the connection sections between the termination and the cryogenic envelope. It is difficult to calculate the electric field of the part with irregular or special structure by resolution analytical methods, and the numerical analysis method is effective to analyze the electric field of the shaped structural part for HTS cable. The electric analysis, simulation, the design and processing of insulation for the two cables are finished based upon these two cables run well by now.


2013 ◽  
Vol 690-693 ◽  
pp. 3132-3135 ◽  
Author(s):  
Guo Jun Jiang ◽  
Sai Zhang

The low productivity of conventional single-needle electrospinning inhibits the application of nanofibers to a commercial level. In order to improve the productivity of the electrospinning technique, a terraced spinneret has been designed based on the finite element analysis in this paper. The electric field distribution was modeled with the use of Ansoft Maxwell software. The experiment results demonstrated this special design spinneret has the potential to produce smooth nanofibers on a large scale.


Sign in / Sign up

Export Citation Format