Robust Light Field Synthesis From Stereo Images With Left-Right Geometric Consistency

Author(s):  
Chun-Hao Chao ◽  
Chang-Le Liu ◽  
Homer H. Chen
2021 ◽  
Author(s):  
Yi-Chou Chen ◽  
Chun-Hao Chao ◽  
Chang-Le Liu ◽  
Kuang-Tsu Shih ◽  
Homer H. Chen
Keyword(s):  

Author(s):  
W. C. T. Dowell

Stereo imaging is not new to electron microscopy. Von Ardenne, who first published transmission pairs nearly forty hears ago, himself refers to a patent application by Ruska in 1934. In the early days of the electron microscope von Ardenne employed a pair of magnetic lenses to view untilted specimens but soon opted for the now standard technique of tilting the specimen with respect to the beam.In the shadow electron microscope stereo images can, of course, be obtained by tilting the specimen between micrographs. This obvious method suffers from the disadvantage that the magnification is very sensitive to small changes in specimen height which accompany tilting in the less sophisticated stages and it is also time consuming. A more convenient method is provided by horizontally displacing the specimen between micrographs. The specimen is not tilted and the technique is both simple and rapid, stereo pairs being obtained in less than thirty seconds.


2020 ◽  
pp. 108-115 ◽  
Author(s):  
Vladimir P. Budak ◽  
Anton V. Grimaylo

The article describes the role of polarisation in calculation of multiple reflections. A mathematical model of multiple reflections based on the Stokes vector for beam description and Mueller matrices for description of surface properties is presented. On the basis of this model, the global illumination equation is generalised for the polarisation case and is resolved into volume integration. This allows us to obtain an expression for the Monte Carlo method local estimates and to use them for evaluation of light distribution in the scene with consideration of polarisation. The obtained mathematical model was implemented in the software environment using the example of a scene with its surfaces having both diffuse and regular components of reflection. The results presented in the article show that the calculation difference may reach 30 % when polarisation is taken into consideration as compared to standard modelling.


2005 ◽  
Vol 6 (2) ◽  
pp. 65 ◽  
Author(s):  
Marc Gerdisch ◽  
Thomas Hinkamp ◽  
Stephen D. Ainsworth

<P>Background: Use of the interrupted coronary anastomosis has largely been abandoned in favor of the more rapid continuous suturing technique. The Coalescent U-CLIP anastomotic device allows the surgeon to create an interrupted distal anastomosis in the same amount of time that it would take to create a continuous anastomosis. This acute bovine study examined the effect of the anastomotic technique on blood flow and vessel wall function. </P><P>Methods: End-to-side coronary anastomoses were created in an open chest bovine model using the left and right internal thoracic arteries and the left anterior descending coronary artery. All other variables except suturing technique were carefully controlled. In each animal, one anastomosis was completed using a continuous suturing technique and the other was performed in an interrupted fashion using the Coalescent U-CLIP anastomotic device. Volumetric flow curves through each graft were analyzed using key indicators of anastomotic quality, and anastomotic compliance was evaluated using intravascular ultrasound. Luminal castings were created of each vessel to examine the interior surface of each anastomosis for constrictions and deformities. </P><P>Results: The interrupted anastomoses created with the Coalescent U-CLIP anastomotic device showed significant differences with respect to anastomotic compliance, pulsatility index, peak flow, and percentage of diastolic flow. The cross-sectional area and degree of luminal deformity were also different for the two suturing techniques. </P><P>Conclusions: In this acute bovine model, interrupted coronary anastomoses demonstrated superior geometric consistency and greater physiologic compliance than did continuously sutured anastomoses. The interrupted anastomosis also caused fewer disturbances to the flow waveform, behaving similarly to a normal vessel wall. The combination of these effects may influence both acute and long-term patency of the coronary bypass grafts.</P>


2016 ◽  
Vol 136 (12) ◽  
pp. 522-531
Author(s):  
Yuta Ideguchi ◽  
Yuki Uranishi ◽  
Shunsuke Yoshimoto ◽  
Yoshihiro Kuroda ◽  
Masataka Imura ◽  
...  
Keyword(s):  

2018 ◽  
Vol 2018 (4) ◽  
pp. 142-1-142-5
Author(s):  
Hiroaki Yano ◽  
Tomohiro Yendo
Keyword(s):  

2019 ◽  
Vol 2019 (3) ◽  
pp. 636-1-636-6
Author(s):  
H. Harlyn Baker ◽  
Gregorij Kurillo ◽  
Allan Miller ◽  
Alessandro Temil ◽  
Tom Defanti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document