Sensorless control of synchronous reluctance motors based on an extended emf model and initial position estimation

Author(s):  
S. Ichikawa ◽  
M. Tomita ◽  
S. Doki ◽  
S. Okuma
Author(s):  
Umesh Kumar Soni ◽  
Ramesh Kumar Tripathi

Background: Brushless DC motors are highly efficient motors due to its high torque to weight ratio, compact design, high speed operating capability and higher power density. Conventional Hall sensor based rotor position sensing is affected by the heating, vibration, interference and noise. Objective: The innovative, cost effective and easily implementable sensorless techniques are essential in order to achieve high efficiency, reduced current and reduced torque pulsations. Further, a delay free, high load fast startup is also important issue. Methods: In this paper an extensive review of various techniques based on the detection of freewheeling diode current, phase back EMF zero crossoing point detection, back EMF integration method and third harmonic back EMF was done. The study and effect of various PWM strategies on back EMF detection was studied. Later on the sensorless schemes based on flux linkage estimation and flux linkage increment were introduced. The load torque observers, unknown input observers, sliding mode observers, L∞-induced observers, H ∞ - deconvolution filter for back EMF estimation were also reviewed. As the brushless DC motors have no back EMF at starting and for back EMF based commutation a minimum speed is required for sufficient back EMF. Therefore various strategies of open and close-loop reduced current startup have been studied to achieve effective commutation without reverse torque. Initial position detection (IPD) schemes, which are mostly based on saliency and current response to inductance variation, is effective where reverse torque is strictly prohibited. A detailed review of these initial position detection techniques (IPD) has also been presented. Results: The detailed mathematical and graphical analysis has been presented here in order to understand the working of the state-of-art sensorless techniques. Conclusion: The back EMF detection using direct and indirect methods of terminal voltage filtering have the problem of delay and attenuation, PWM noise, freewheeling diode spikes and disturbance in detected back EMFs is a drawback. The parameter detuning, underestimation and overestimation, offset problem, system noise and observer gain variation etc. limit the applicability of observer based technique. Therefore, a more robust and precise position estimation scheme is essential.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1254
Author(s):  
Gianluca Brando ◽  
Adolfo Dannier ◽  
Ivan Spina

This paper focuses on the performance analysis of a sensorless control for a Doubly Fed Induction Generator (DFIG) in grid-connected operation for turbine-based wind generation systems. With reference to a conventional stator flux based Field Oriented Control (FOC), a full-order adaptive observer is implemented and a criterion to calculate the observer gain matrix is provided. The observer provides the estimated stator flux and an estimation of the rotor position is also obtained through the measurements of stator and rotor phase currents. Due to parameter inaccuracy, the rotor position estimation is affected by an error. As a novelty of the discussed approach, the rotor position estimation error is considered as an additional machine parameter, and an error tracking procedure is envisioned in order to track the DFIG rotor position with better accuracy. In particular, an adaptive law based on the Lyapunov theory is implemented for the tracking of the rotor position estimation error, and a current injection strategy is developed in order to ensure the necessary tracking sensitivity around zero rotor voltages. The roughly evaluated rotor position can be corrected by means of the tracked rotor position estimation error, so that the corrected rotor position is sent to the FOC for the necessary rotating coordinate transformation. An extensive experimental analysis is carried out on an 11 kW, 4 poles, 400 V/50 Hz induction machine testifying the quality of the sensorless control.


2021 ◽  
Vol 12 (1) ◽  
pp. 9
Author(s):  
Yong Li ◽  
Hao Wu ◽  
Xing Xu ◽  
Xiaodong Sun ◽  
Jindong Zhao

Permanent magnet traction motor has the advantages of high efficiency, high power density, high torque density and quick dynamic response, which has been widely used in the traction field of electric vehicle. The high-performance control of permanent magnet traction motor depends on accurate rotor position information, which is usually obtained by using mechanical position sensors such as hall sensor, encoder and rotary transformer. However, the traditional mechanical sensor has the disadvantages of high cost, large volume and poor anti-interference ability, which limits the application of permanent magnet motor. The sensorless control technology is an effective way to solve the above-mentioned problem. Firstly, the sensorless control techniques of permanent magnet motor are classified. The sensorless control techniques of permanent magnet motor for rotor initial position, zero-low speed range, medium-high speed range and full speed range are deeply described and compared. Finally, the development trend of sensorless control technology of permanent magnet traction motor is prospected.


Sign in / Sign up

Export Citation Format

Share Document