Dandelion flower like GaN humidity sensor: Fabrication and its excellent linearity towards entire relative humidity range

2020 ◽  
pp. 1-1
Author(s):  
Manimuthu Veerappan ◽  
Xiaohui Leng ◽  
Dan Luo ◽  
Fei Wang
RSC Advances ◽  
2022 ◽  
Vol 12 (2) ◽  
pp. 1157-1164
Author(s):  
Parag V. Adhyapak ◽  
Aishwarya M. Kasabe ◽  
Amruta D. Bang ◽  
Jalindar Ambekar ◽  
Sulabha K. Kulkarni

A novel, highly sensitive gold nanowire (AuNW) resistive sensor is reported here for humidity sensing in the relative humidity range of 11% to 92% RH as well as for breath sensing.


2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Chunjie Wang ◽  
Aihua Zhang ◽  
Hamid Reza Karimi

The humidity sensitive characteristics of the sensor fabricated from 10 mol% La2O3doped CeO2nanopowders with particle size 17.26 nm synthesized via hydrothermal method were investigated at different frequencies. It was found that the sensor shows high humidity sensitivity, rapid response-recovery characteristics, and narrow hysteresis loop at 100 Hz in the relative humidity range from 11% to 95%. The impedance of the sensor decreases by about five orders of magnitude as relative humidity increases. The maximum humidity hysteresis is about 6% RH, and the response and recovery time is 12 and 13 s, respectively. These results indicate that the nanosized La2O3doped CeO2powder has potential application as high-performance humidity sensor.


Beverages ◽  
2019 ◽  
Vol 5 (4) ◽  
pp. 60
Author(s):  
Noemí del Toro del Toro ◽  
Fredy Fong Casas ◽  
Julio Ayan Rial ◽  
Maria Caridad Portuondo González ◽  
Harold Crespo Sariol ◽  
...  

The Boltzmann equation is applied to fit data of volume loss for evaporation (in %) during spirit ageing in northern white oak (Quercus Alba) standard barrels of 205 L (+/− 10 L) using a temperature and humidity controlled cellar. The Boltzmann equation satisfactory fitted to the experimental data of the volume loss against temperature at constant humidity. Two parameters of the Boltzmann equation showed a linear dependency on the relative humidity of the air, while the other two parameters exhibited a constant value independently of the air humidity. The found empirical mathematical model can be used to calculate the volume loss for evaporation of spirits (40% v/v of ethanol) during ageing in terms of relative humidity (range: 40%–95%) and temperature (range: 10–30 °C) with significant accuracy.


2017 ◽  
Vol 5 (16) ◽  
pp. 3924-3931 ◽  
Author(s):  
Elena Colusso ◽  
Giovanni Perotto ◽  
Yu Wang ◽  
Marco Sturaro ◽  
Fiorenzo Omenetto ◽  
...  

A bioinspired multilayer film made of a new silk–titanate nanocomposite material, showing a humidity-responsive behavior, has been fabricated. The multilayer structure mimics the structure of the cuticle of the Hoplia coerulea beetle and shows long-term stability over a very large relative humidity range.


1952 ◽  
Vol 43 (1) ◽  
pp. 111-144 ◽  
Author(s):  
R. W. Howe

In Nigeria, shelled groundnuts are stored in sacks in covered warehouses and as pyramids in the open air. At the beginning of storage the nuts comprise approximately equal quantities of whole, split and broken nuts of a moisture content of 3·4 per cent. The sacks are exposed to direct hot sun whilst stacking.The mean monthly maximum shade temperature in Kano ranges from 101°F. in April to 85°F. in January and August and the mean monthly minimum from 75°F. in May to 56°F. in January. Monthly maximum relative humidities range from 100 per cent, in August and September to 45 per cent, in February, and the monthly minimum from 71 per cent, in August to 12 per cent, in February. The range of mean relative humidity is 81 per cent, in August and 18 per cent, in February. Rains fall between April and September, 70 per cent, falling in July and August. Heavy falls are recorded on about 25 days.Inside warehouses, the maximum monthly temperatures are 102°F. in May and 79°F. in January and February, and minimum temperatures are 81°F. in June, and 58°F. in February. In August the mean relative humidity range is 93 per cent, to 70 per cent. In December it is 34 per cent. to 20 per cent.Just under the roof of a warehouse and on the surface of pyramids the diurnal range is very large.


2004 ◽  
Vol 100 (1-2) ◽  
pp. 126-130 ◽  
Author(s):  
P. Bruno ◽  
G. Cicala ◽  
F. Corsi ◽  
A. Dragone ◽  
A.M. Losacco

2021 ◽  
Vol 9 (3) ◽  
pp. 276-278
Author(s):  
Naresh Kumar ◽  

The relative humidity studies revealed that maximum mycelial of fungus was observed at 90 per cent relative humidity (89.00 mm), which was followed by 100 per cent (86.30 mm). The least mycelia growth was observed at 50 per cent (45.30 mm). A significant decrease in mycelium growth was observed at 80, 70 and 60 per cent (80.40 mm, 70.20 mm and 57.00 mm) humidity level, respectively. Each fungus has its relative humidity range for the growth.


Chemosensors ◽  
2020 ◽  
Vol 8 (2) ◽  
pp. 39 ◽  
Author(s):  
Maria Vesna Nikolic ◽  
Miloljub D. Lukovic

A porous MgFe2O4-Fe2O3-SnO2 bulk compound with varying SnO2 content was obtained by sintering an appropriate mixture of magnesium oxide, hematite and tin oxide nanopowders at 1000 and 1100 °C. The obtained structure was confirmed by X-ray diffraction analysis. Scanning electron microscopy was used to analyze sample morphology, showing that the addition of SnO2 resulted in an inhomogeneous microstructure with smaller grain size especially at 1000 °C. Significant grain growth of hematite grains was noted at 1100 °C. The influence of relative humidity in the range 30–90% was monitored at room temperature (25 °C) in the frequency range 42 Hz- 1 MHz. The highest reduction of impedance with humidity was noted at lower frequency. Addition of low amounts of SnO2 and sintering at 1000 °C resulted in the highest sensitivity at 105 Hz of 0.391 MΩ/%RH in the RH30–90% range, while the compound with the highest amount of SnO2 showed the largest decrease in impedance with increase in relative humidity ~26 times. All samples showed low hysteresis (below 2%). Complex impedance data was analyzed using equivalent circuits reflecting the dominant influence of the grain boundary in the lower relative humidity range (30–60%) and both grain boundary and grain components in the higher relative humidity range (60–90%).


2013 ◽  
Vol 561 ◽  
pp. 341-346
Author(s):  
Meng Wang ◽  
Ze Guang Lu ◽  
Wan Da Jia ◽  
Huai Yan Zhao ◽  
Feng Shuang Wang

The moisture evaporation amount and drying velocity of monocomponent sealer on the maple-veneered panels as base materials, under the drying conditions of constant temperature of 30°C and relative humidity varied from 30% to 70%, were measured in this study. The results indicated that the moisture evaporation amount increased, and drying velocity decreased with drying time under the same relative humidity, while the moisture evaporation amount decreased with the increase of relative humidity. The drying velocities were remarkable different under different relative humidities. During the same period of drying time, the difference degree of moisture evaporation amount within the relative humidity range of 30% to 50% was smaller than that within the relative humidity range of 50% to 70%.


Sign in / Sign up

Export Citation Format

Share Document