A laser anemometer reference for AIR data calibration

Author(s):  
J. Mandle
Radiocarbon ◽  
2021 ◽  
pp. 1-12
Author(s):  
G Quarta ◽  
M Molnár ◽  
I Hajdas ◽  
L Calcagnile ◽  
I Major ◽  
...  

ABSTRACT The application of accelerator mass spectrometry radiocarbon (AMS 14C) dating in forensics is made possible by the use of the large excursion of the 14C concentration in the post-WWII terrestrial atmosphere due to nuclear testing as a reference curve for data calibration. By this approach high-precision analyses are possible on samples younger than ∼70 years. Nevertheless, the routine, widespread application of the method in the practice of forensics still appears to be limited by different issues due to possible complex interpretation of the results. We present the results of an intercomparison exercise carried out in the framework of an International Atomic Energy Agency (IAEA) CRP-Coordinated Research Project between three AMS laboratories in Italy, Hungary, and Switzerland. Bone and ivory samples were selected with ages spanning from background (>50 ka) to 2018. The results obtained allow us to assess the high degree of reproducibility of the results and the remarkable consistency of the experimental determinations.


Author(s):  
Xianda Chen ◽  
Yifei Xiao ◽  
Yeming Tang ◽  
Julio Fernandez-Mendoza ◽  
Guohong Cao

Sleep apnea is a sleep disorder in which breathing is briefly and repeatedly interrupted. Polysomnography (PSG) is the standard clinical test for diagnosing sleep apnea. However, it is expensive and time-consuming which requires hospital visits, specialized wearable sensors, professional installations, and long waiting lists. To address this problem, we design a smartwatch-based system called ApneaDetector, which exploits the built-in sensors in smartwatches to detect sleep apnea. Through a clinical study, we identify features of sleep apnea captured by smartwatch, which can be leveraged by machine learning techniques for sleep apnea detection. However, there are many technical challenges such as how to extract various special patterns from the noisy and multi-axis sensing data. To address these challenges, we propose signal denoising and data calibration techniques to process the noisy data while preserving the peaks and troughs which reflect the possible apnea events. We identify the characteristics of sleep apnea such as signal spikes which can be captured by smartwatch, and propose methods to extract proper features to train machine learning models for apnea detection. Through extensive experimental evaluations, we demonstrate that our system can detect apnea events with high precision (0.9674), recall (0.9625), and F1-score (0.9649).


2019 ◽  
Vol 71 (1) ◽  
Author(s):  
Bin Zhou ◽  
Bingjun Cheng ◽  
Xiaochen Gou ◽  
Lei Li ◽  
Yiteng Zhang ◽  
...  

Abstract The High Precision Magnetometer (HPM) is one of the main payloads onboard the China Seismo-Electromagnetic Satellite (CSES). The HPM consists of two Fluxgate Magnetometers (FGM) and the Coupled Dark State Magnetometer (CDSM), and measures the magnetic field from DC to 15 Hz. The FGMs measure the vector components of the magnetic field; while the CDSM detects the magnitude of the magnetic field with higher accuracy, which can be used to calibrate the linear parameters of the FGM. In this paper, brief descriptions of measurement principles and performances of the HPM, ground, and in-orbit calibration results of the FGMs are presented, including the thermal drift and magnetic interferences from the satellite. The HPM in-orbit vector data calibration includes two steps: sensor non-linearity corrections based on on-ground calibration and fluxgate linear parameter calibration based on the CDSM measurements. The calibration results show a reasonably good stability of the linear parameters over time. The difference between the field magnitude calculated from the calibrated FGM components and the magnitude directly measured by the CDSM is just 0.5 nT (1σ) when the linear parameters are fitted separately for the day- and the night-side. Satellite disturbances have been analyzed including soft and hard remanence as well as magnetization of the magnetic torquer, radiation from the Tri-Band Beacon, and interferences from the rotation of the solar wing. A comparison shows consistency between the HPM and SWARM magnetic field data. Observation examples are introduced in the paper, which show that HPM data can be used to survey the global geomagnetic field and monitor the magnetic field disturbances in the ionosphere.


Geophysics ◽  
2013 ◽  
Vol 78 (6) ◽  
pp. R249-R257 ◽  
Author(s):  
Maokun Li ◽  
James Rickett ◽  
Aria Abubakar

We found a data calibration scheme for frequency-domain full-waveform inversion (FWI). The scheme is based on the variable projection technique. With this scheme, the FWI algorithm can incorporate the data calibration procedure into the inversion process without introducing additional unknown parameters. The calibration variable for each frequency is computed using a minimum norm solution between the measured and simulated data. This process is directly included in the data misfit cost function. Therefore, the inversion algorithm becomes source independent. Moreover, because all the data points are considered in the calibration process, this scheme increases the robustness of the algorithm. Numerical tests determined that the FWI algorithm can reconstruct velocity distributions accurately without the source waveform information.


1994 ◽  
Vol 347 ◽  
Author(s):  
J.Ch. Bolomey ◽  
G. Cottard ◽  
P. Berthaud ◽  
A. Lemaitre ◽  
J. F. Portala

ABSTRACTMicrowave multiport sensors have been shown to provide some unique capabilities to achieve real-time testing of products conveyed at high speed. In many applications, quantitative measurements of physical quantities such as moisture content, density, etc… are required, either to guarantee reliable production or to optimally control a fabrication/transformation process. In this paper, different ways of extracting such physical quantities from microwave measurements performed by multiport sensors are presented. Model approaches are used, based on polynomial expansions of the physical quantities to be measured as a function of the microwave amplitude and phase data. Calibration procedures have been investigated for both paper and wood material samples. Comparisons between in-situ, microwave and conventional, measurements are analysed.


1983 ◽  
Vol 49 (1-3) ◽  
pp. 155-162 ◽  
Author(s):  
L.M. Ikioka ◽  
R.D. Brum ◽  
G.S. Samuelsen
Keyword(s):  

1975 ◽  
Vol 29 (5) ◽  
pp. 1408-1410 ◽  
Author(s):  
I. L. Povkh ◽  
A. B. Stupin ◽  
S. N. Maksyutenko ◽  
P. V. Aslanov ◽  
E. A. Roshchin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document