Comparative Study of Lateral and Trench Power MOSFETs in Multi-MHz Buck Converter Applications

Author(s):  
Yali Xiong ◽  
Xu Cheng ◽  
David Okada ◽  
Z. John Shen
2008 ◽  
Vol 2008 ◽  
pp. 1-9 ◽  
Author(s):  
Yali Xiong ◽  
Xu Cheng ◽  
Xiangcheng Wang ◽  
Pavan Kumar ◽  
Lina Guo ◽  
...  

This paper investigates the performance perspectives and theoretical limitations of trench power MOSFETs in synchronous rectifier buck converters operating in the MHz frequency range. Several trench MOSFET technologies are studied using a mixed-mode device/circuit modeling approach. Individual power loss contributions from the control and synchronous MOSFETs, and their dependence on switching frequency between 500 kHz and 5 MHz are discussed in detail. It is observed that the conduction loss contribution decreases from 40% to 4% while the switching loss contribution increases from 60% to 96% as the switching frequency increases from 500 KHz to 5 MHz. Beyond 1 MHz frequency there is no obvious benefit to increase the die size of either SyncFET or CtrlFET. The RDS(ON)×QG figure of merit (FOM) still correlates well to the overall converter efficiency in the MHz frequency range. The efficiency of the hard switching buck topology is limited to 80% at 2 MHz and 65% at 5 MHz even with the most advanced trench MOSFET technologies.


Sign in / Sign up

Export Citation Format

Share Document