Fundamental Properties of the High Pressure Hydrogen Microdischarges in Static and Time-Varying Electric Fields

2017 ◽  
Vol 45 (6) ◽  
pp. 913-917
Author(s):  
Matej Klas ◽  
Ladislav Moravsky ◽  
Stefan Matejcik ◽  
Branislav Radjenovic ◽  
Marija Radmilovic-Radjenovic
2021 ◽  
Vol 23 (7) ◽  
pp. 4277-4286
Author(s):  
S. V. Chuvikov ◽  
E. A. Berdonosova ◽  
A. Krautsou ◽  
J. V. Kostina ◽  
V. V. Minin ◽  
...  

Pt-Catalyst plays a key role in hydrogen adsorption by Cu-BTC at high pressures.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Martin L. Pall

Abstract Millimeter wave (MM-wave) electromagnetic fields (EMFs) are predicted to not produce penetrating effects in the body. The electric but not magnetic part of MM-EMFs are almost completely absorbed within the outer 1 mm of the body. Rodents are reported to have penetrating MM-wave impacts on the brain, the myocardium, liver, kidney and bone marrow. MM-waves produce electromagnetic sensitivity-like changes in rodent, frog and skate tissues. In humans, MM-waves have penetrating effects including impacts on the brain, producing EEG changes and other neurological/neuropsychiatric changes, increases in apparent electromagnetic hypersensitivity and produce changes on ulcers and cardiac activity. This review focuses on several issues required to understand penetrating effects of MM-waves and microwaves: 1. Electronically generated EMFs are coherent, producing much higher electrical and magnetic forces then do natural incoherent EMFs. 2. The fixed relationship between electrical and magnetic fields found in EMFs in a vacuum or highly permeable medium such as air, predicted by Maxwell’s equations, breaks down in other materials. Specifically, MM-wave electrical fields are almost completely absorbed in the outer 1 mm of the body due to the high dielectric constant of biological aqueous phases. However, the magnetic fields are very highly penetrating. 3. Time-varying magnetic fields have central roles in producing highly penetrating effects. The primary mechanism of EMF action is voltage-gated calcium channel (VGCC) activation with the EMFs acting via their forces on the voltage sensor, rather than by depolarization of the plasma membrane. Two distinct mechanisms, an indirect and a direct mechanism, are consistent with and predicted by the physics, to explain penetrating MM-wave VGCC activation via the voltage sensor. Time-varying coherent magnetic fields, as predicted by the Maxwell–Faraday version of Faraday’s law of induction, can put forces on ions dissolved in aqueous phases deep within the body, regenerating coherent electric fields which activate the VGCC voltage sensor. In addition, time-varying magnetic fields can directly put forces on the 20 charges in the VGCC voltage sensor. There are three very important findings here which are rarely recognized in the EMF scientific literature: coherence of electronically generated EMFs; the key role of time-varying magnetic fields in generating highly penetrating effects; the key role of both modulating and pure EMF pulses in greatly increasing very short term high level time-variation of magnetic and electric fields. It is probable that genuine safety guidelines must keep nanosecond timescale-variation of coherent electric and magnetic fields below some maximum level in order to produce genuine safety. These findings have important implications with regard to 5G radiation.


Antioxidants ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 54
Author(s):  
Monika Mieszczakowska-Frąc ◽  
Karolina Celejewska ◽  
Witold Płocharski

Nowadays, thermal treatments are used for extending the shelf-life of vegetable and fruit products by inactivating microorganisms and enzymes. On the other hand, heat treatments often induce undesirable changes in the quality of the final product, e.g., losses of nutrients, color alterations, changes in flavor, and smell. Therefore, the food industry is opening up to new technologies that are less aggressive than thermal treatment to avoid the negative effects of thermal pasteurization. Non-thermal processing technologies have been developed during the last decades as an alternative to thermal food preservation. Processing changes the structure of fruit and vegetables, and hence the bioavailability of the nutrients contained in them. In this review, special attention has been devoted to the effects of modern technologies of fruit and vegetable processing, such as minimal processing (MPFV), high-pressure processing (HPP), high-pressure homogenization (HPH), ultrasounds (US), pulsed electric fields (PEF), on the stability and bioavailability of vitamin C.


2019 ◽  
Vol 40 (7) ◽  
pp. 1092-1095 ◽  
Author(s):  
Seungyeol Oh ◽  
Jeonghwan Song ◽  
In Kyeong Yoo ◽  
Hyunsang Hwang

Author(s):  
Hideki Nakagawa

Practical application of fuel cell vehicle has started in the world, and high-pressure hydrogen tanks are currently considered to be the mainstream hydrogen storage system for commercially implemented fuel cell vehicle. Application of metallic materials to the components of high-pressure hydrogen storage system: hydrogen tanks, valves, measuring instructions and so on, have been discussed. In this work, tensile properties of four types of stainless steels were evaluated in 45MPa (6527psig) and 75MPa (10878psig) high-pressure gaseous hydrogen at a slow strain rate of 3×10−6 s−1 at ambient temperature. Type 316L (UNS S31603) stainless steel hardly showed ductility loss in gaseous hydrogen, since it had stable austenitic structure. On the other hand, Type 304 (UNS S30400) metastable austenitic stainless steel showed remarkable ductility loss in gaseous hydrogen, which was caused by the hydrogen embrittlement of strain induced martensitic phase. Likewise, Type 205 (UNS S20500) nitrogen-strengthened austenitic stainless steel showed remarkable ductility loss in gaseous hydrogen, though it had stable austenitic structure in the same manner as Type 316L. The ductility loss of Type 205 was due to the hydrogen embrittlement of austenitic phase resulting from the formation of planar dislocation array. Furthermore, Type 329J4L (UNS S31260) duplex stainless steel showed extreme ductility loss in gaseous hydrogen, which was caused by the hydrogen embrittlement of ferritic phase.


Hyomen Kagaku ◽  
2015 ◽  
Vol 36 (11) ◽  
pp. 562-567
Author(s):  
Hisao MATSUNAGA ◽  
Junichiro YAMABE ◽  
Saburo MATSUOKA

Author(s):  
Z. Y. Li ◽  
C. L. Zhou ◽  
Y. Z. Zhao ◽  
Z. L. Hua ◽  
L. Zhang ◽  
...  

Crack growth analysis (CGA) was applied to estimate the cycle life of the high-pressure hydrogen equipment constructed by the practical materials of 4340 (two heats), 4137, 4130X, A286, type 316 (solution-annealed (SA) and cold-worked (CW)), and type 304 (SA and CW) in 45, 85 and 105 MPa hydrogen and air. The wall thickness was calculated following five regulations of the High Pressure Gas Safety Institute of Japan (KHK) designated equipment rule, KHKS 0220, TSG R0002, JB4732, and ASME Sec. VIII, Div. 3. We also applied CGA for four typical model materials to discuss the effect of ultimate tensile strength (UTS), pressure and hydrogen sensitivity on the cycle life of the high-pressure hydrogen equipment. Leak before burst (LBB) was confirmed in all practical materials in hydrogen and air. The minimum KIC required for LBB of the model material with UTS of even 1500 MPa was 170 MPa·m0.5 in 105 MPa. Cycle life qualified 103 cycles for all practical materials in air. In 105 MPa hydrogen, the cycle life by KIH was much shorter than that in air for two heats of 4340 and 4137 sensitive to hydrogen gas embrittlement (HGE). The cycle life of type 304 (SA) sensitive to HGE was almost above 104 cycles in hydrogen, while the cycle life of type 316 (SA and CW) was not affected by hydrogen and that of A286 in hydrogen was near to that in air. It was discussed that the cycle life increased with decreasing pressure or UTS in hydrogen. This behavior was due to that KIH increased or fatigue crack growth (FCG) decreased with decreasing pressure or UTS. The cycle life data of the model materials under the conditions of the pressure, UTS, KIH, FCG and regulations in both hydrogen and air were proposed quantitatively for materials selection for high-pressure hydrogen storage.


Sign in / Sign up

Export Citation Format

Share Document