A New Secure Scan Design with PUF-based Key for Authentication

Author(s):  
Qidong Wang ◽  
Aijiao Cui ◽  
Gang Qu ◽  
Huawei Li
Keyword(s):  
Author(s):  
Yuki YOSHIKAWA ◽  
Tomomi NUWA ◽  
Hideyuki ICHIHARA ◽  
Tomoo INOUE

Author(s):  
T. Kiyan ◽  
C. Boit ◽  
C. Brillert

Abstract In this paper, a methodology based upon laser stimulation and a comparison of continuous wave and pulsed laser operation will be presented that localizes the fault relevant sites in a fully functional scan chain cell. The technique uses a laser incident from the backside to inject soft faults into internal nodes of a master-slave scan flip-flop in consequence of localized photocurrent. Depending on the illuminated type of the transistors (n- or p-type), injection of a logic ‘0’ or ‘1’ into the master or the slave stage of a flip-flop takes place. The laser pulse is externally triggered and can easily be shifted to various time slots in reference to clock and scan pattern. This feature of the laser diode allows triggering the laser pulse on the rising or the falling edge of the clock. Therefore, it is possible to choose the stage of the flip-flop in which the fault injection should occur. It is also demonstrated that the technique is able to identify the most sensitive signal condition for fault injection with a better time resolution than the pulse width of the laser, a significant improvement for failure analysis of integrated circuits.


2021 ◽  
Vol 9 (6) ◽  
pp. 62
Author(s):  
Sofia Stromeyer ◽  
Daniel Wiedemeier ◽  
Albert Mehl ◽  
Andreas Ender

The purpose of this in vitro study was to compare the time efficiency of digital chairside and labside workflows with a conventional workflow for single-unit restorations. The time efficiency in this specific sense was defined as the time, which has to be spent in a dental office by a dental professional performing the relevant steps. A model with interchangeable teeth on position 36 was created. These teeth were differently prepared, responding to several clinical situations to perform single-unit restorations. Different manufacturing techniques were used: For the digital workflows, CEREC Omnicam (CER) and Trios 3 (TN/TI) were used. The conventional workflow, using a dual-arch tray impression technique, served as the control group. For the labside workflow (_L) and the conventional impression procedure (CO), the time necessary for the impressions and temporary restorations was recorded and served as operating time. The chairside workflow time was divided by the time for the entire workflow (_C) including scan, design, milling and finishing the milled restoration, and in the actual working time (_CW) leaving out the chairside milling of the restoration. Labside workflow time ranged from 9 min 27 s (CER_L) to 12 min 41 s (TI_L). Entire chairside time ranged from 43 min 35 s (CER_C) to 58 min 43 s (TI_C). Pure chairside working time ranged from 15 min 21 s (CER_CW) to 23 min 17 s (TI_CW). Conventional workflow time was 10 min 39 s (CO) on average. The digital labside workflow and the conventional workflow require a similar amount of time. The digital chairside workflow is more time consuming.


2002 ◽  
Author(s):  
Zhang Liang ◽  
He Xiangqing
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document