scholarly journals Utility of contrast‐enhanced echocardiography in the diagnosis and follow‐up of a pseudoaneurysm of the aortic arch

2021 ◽  
Author(s):  
Yu Wu ◽  
Jia Xu ◽  
Menghe Wang ◽  
Yuman Li ◽  
Qing Lv

Author(s):  
Yu Wu ◽  
Yuman Li ◽  
Jia Xu ◽  
Wang Menghe ◽  
Qing Lv

Spontaneous pseudoaneurysm of the aortic arch is an exceptionally rare and potentially life-threatening condition.Diagnosis of pseudoaneurysms of the aortic arch mainly depends on imaging examinations.Contrast-enhanced echocardiography, as a non-invasive, bed-side and radiation-free tool, plays an important role in the rapid diagnosis and postoperative follow-up of pseudoaneurysms of the aortic arch.



2008 ◽  
Vol 47 (01) ◽  
pp. 37-42 ◽  
Author(s):  
T. Pfluger ◽  
V. Schneider ◽  
M. Hacker ◽  
N. Bröckel ◽  
D. Morhard ◽  
...  

SummaryAim: Assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [18F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CECT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for >6 months. Results: Region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/ CE-CT as compared to PET/LD-CT. Conclusion: Overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma.



Author(s):  
Xiangmin Li ◽  
Zhenpeng Peng ◽  
Xuhui Zhou ◽  
Zhi Dong ◽  
Chaogui Yan ◽  
...  


Author(s):  
Vito Cantisani ◽  
Nicola Di Leo ◽  
Emanuele David ◽  
Dirk-André Clevert

AbstractIn recent years, the implementation of contrast-enhanced ultrasound (CEUS) in clinical practice has opened new horizons in the arterial pathologies research field, since this technique is able to supply new sets of data that can be crucial in patient management. The main applications of CEUS in the arterial system are the detection, characterization, and follow-up of carotid plaques and endoleaks after EVAR. Other situations in which CEUS was demonstrated to be a useful tool are large vessel vasculitis, dissections, and untreated aneurysms. In carotid atherosclerosis CEUS is not only able to acquire quantitative data about stenosis but also to perform a qualitative assessment of the plaque. The most important plaque features that CEUS is able to depict are ulceration, neovascularization, and the presence of inflammatory infiltrates. All of these factors contribute to plaque vulnerability. Thus, CEUS is crucial in order to allow better risk stratification and management of patients. In follow-up after EVAR, CEUS shows sensitivity and specificity values similar to CTA while ensuring several advantages, such as lower cost and the absence of ionizing radiation and nephrotoxic agents. Moreover, CEUS is able to offer real-time evaluation of endoleaks and thus is a useful tool in cases that are ambiguous on CTA. Most limitations are patient-related and are the same as in all other ultrasound techniques, such as high BMI and meteorism.



2016 ◽  
Author(s):  
S. Dash ◽  
A. Goel ◽  
S. Sogani

Purpose: To evaluate the role of 18F-FDG PET with contrast enhanced CT (PET-CECT) in early detection of recurrence in follow up patients of carcinoma cervix. Methods: Patients with histopathologically proven carcinoma cervix who underwent chemotherapy, radiotherapy and/or surgery and on follow up were recruited in the study. Fifty-two patients underwent 18F-FDG PET-CECT for detection of recurrence. The median age was 51.5 (average = 53.4) years. PET-CECT studies were evaluated and analyzed separately by an experienced nuclear medicine physician and a radiologist independently. The physicians were blinded for the patient history. PET-CECT results were validated with histopathological correlation, conventional radiologic imaging/follow up PET-CECT study and clinical follow up. Results: Out of 52 patients, 34 patients were reported as positive for recurrence, 17 of these were having active local recurrence and 31 patients had regional lymph nodal metastases, 14 patients had distant metastases (out of them 6 patients had distant lymph node metastases, 6 had pulmonary metastases, 4 had skeletal metastases and two had liver metastases). Remaining 18 patients were reported as negative for recurrence. The lung was the most common site for distant metastasis. Patient were then further evaluated based on histopathological correlation, conventional radiologic imaging and follow up PET-CECT scan and five were found to be false positive and one patient was identified as false negative. The sensitivity, specificity, positive and negative predictive value were derived to be 96.7%, 77.3%, 85.3% and 94.4%, respectively. Accuracy was calculated to be 88.5%. Conclusions: 18F-FDG PET-CECT is a very useful non-invasive modality for the early detection of recurrence and metastatic workup in patients with carcinoma cervix with a very high sensitivity and negative predictive value. It is also useful in targeting biopsy sites in suspected cases of recurrence.



2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
G Amir ◽  
N Soffair ◽  
G Frenkel ◽  
E Bruckheimer ◽  
E Nachum ◽  
...  

Abstract Background Vascular anomalies of the Aortic arch can cause respiratory symptoms in children due to tracheal compression. Treatment consists of division of the vascular rings, nevertheless data regarding mid- term results is scarce. The purpose of this study was to evaluate clinical results of vascular ring surgery. Methods Between2007–2014, 85 children underwent vascular ring surgery. 51 had Double Aortic Arch (DAA, 60%), 31 Right Arch with Aberrant Subclavian Artery (RAA & ALSA, 36.5%) and 3 had RAA, mirror image branching & left ductus arteriosus (3.5%). Mean age and weight at operation were 12.4±13months and 8.6±4.1 kg respectively. Mid-term follow-up included clinical follow up by a pulmonologist (38 patients, 44.7%) and a telephone questionnaire (71 patients, 83%) performed 57±25.7 months after surgery. Results In most patients, symptomatic relief occurred in less than 6 months (table 1). Mid –term follow up revealed that although most parents described a significant improvement in their child's respiratory symptoms (95%), a significant number of patients described some residual respiratory symptoms (table 2). We did not find any significant association between age at surgery (under 6 month), or vascular ring anatomy (DAA vs. RAA&ASA) and the presence of residual symptoms at follow up Conclusions Surgical division of vascular rings results in a significant clinical improvement within one year, nevertheless many patients remain symptomatic to some degree. We found no association between the age at surgery or anatomic variant to the presence of symptoms in mid- term follow up. Further evaluation whether a more aggressive surgical approach is warranted in order to decrease the incidence long-term symptoms. Funding Acknowledgement Type of funding source: None



Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 486
Author(s):  
Akihiro Funaoka ◽  
Kazushi Numata ◽  
Atsuya Takeda ◽  
Yusuke Saigusa ◽  
Yuichirou Tsurugai ◽  
...  

Radiotherapy is one of the available curative therapies for hepatocellular carcinoma (HCC). We investigate the use of contrast-enhanced ultrasound using Sonazoid (SCEUS) in evaluating the efficacy of radiotherapy for HCC. We enrolled 59 patients with 59 HCCs in this retrospective study. Tumor size and tumor vascularity were evaluated using SCEUS before and 1, 3, 7, 10, and 13 months after radiotherapy. The median follow-up period was 44.5 months (range: 16–82 months). Of the HCCs, 95% (56/59) had no local recurrence, while 5% (3/59) did. At 13 months after radiotherapy, in cases with no local recurrence, SCEUS showed a reduction in tumor vascularity in all cases, while tumor size reduction (>30% reduction, compared with pre-radiotherapy) was observed in 82.1% (46/56). In all three cases of local recurrence, vascularity and tumor size reduction were not observed during the follow-up period and residual HCCs were demonstrated pathologically. Compared with cases with local recurrence, tumor size reduction and reduction in tumor vascularity (p < 0.001) were significantly greater in cases with no local recurrence at 13 months after radiotherapy. SCEUS may be useful in evaluating radiotherapy efficacy for HCC.



BMC Cancer ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Wei Chen ◽  
Yu kun Luo ◽  
Ying Zhang ◽  
Qing Song ◽  
Jie Tang

Abstract Background Treatment for radioiodine refractory differentiated thyroid carcinoma (RR-DTC) is challenging. The purpose of this study was to assess the efficacy and safety of ultrasound-guided implantation of radioactive 125I-seed in radioiodine refractory differentiated thyroid carcinoma. Methods Thirty-six cervical metastatic lymph nodes (CMLNs) diagnosed with RR-DTC from 18 patients were enrolled in this retrospective study. US and contrast-enhanced ultrasound (CEUS) examinations were performed before implantation. Follow-up comprised US, CEUS, thyroglobulin (Tg) level and routine hematology at 1–3, 6, 9 and 12 months and every 6 months thereafter. The volumes of the nodules were compared before implantation and at each follow-up point. The volume reduction rate (VRR) of nodules was also recorded. Results The median volume of the nodules was 523 mm3 (148, 2010mm3) initially, which decreased significantly to 53mm3 (0, 286mm3) (P < 0.01) at the follow-up point of 24 months with a median VRR as 95% (86,100%). During the follow-up period (the range was 24–50 months), 25 (69%) nodules had VRR greater than 90%, of which 12 (33%) nodules had VVR ≈ 100% with unclear structures and only 125I seed images were visible in the US. At the last follow-up visit, the serum Tg level decreased from 57.0 (8.6, 114.8) ng/ml to 4.9 (0.7, 50.3) ng/ml, (P < 0.01). Conclusion US-guided 125I seed implantation is safety and efficacy in treating RR- DTC. It could be an effective supplement for the comprehensive treatment of thyroid cancer.



2018 ◽  
Vol 84 (2) ◽  
pp. 208-214 ◽  
Author(s):  
R. Viola Mebert ◽  
Beat SchnÜRiger ◽  
Daniel Candinas ◽  
Tobias Haltmeier

Nonoperative management of blunt splenic and hepatic injuries has become the standard of care for hemodynamically stable patients. However, nonoperative management may lead to delayed complications and appropriate follow-up is therefore crucial. The aim of this systematic literature review was to assess the role of different imaging modalities in the follow-up assessment of patients with blunt splenic or hepatic injuries using the PubMed database. Eighteen studies were found to be relevant to the topic. A total of 2725 patients were enrolled in the included studies. Both retrospective and prospective studies, but no randomized controlled trials were found. In these studies, CT, ultrasound, and contrast-enhanced ultrasound were discussed. CT was the most commonly used imaging modality. Taking into account all studies included, only one patient underwent intervention due to a complication diagnosed by follow-up CTscan in the absence of clinical signs and symptoms. This equates to a total of 920 CT scans performed to diagnose one clinically nonevident complication that required intervention. Based on the reviewed literature, routine imaging follow-up CT scans may not be indicated in asymptomatic patients with lower grade blunt splenic or hepatic injuries. Contrast-enhanced ultrasound is a promising alternative imaging modality for the follow-up of these patients.



Sign in / Sign up

Export Citation Format

Share Document