Biological variation data and analytical specification goal estimates of the thrombin generation assay with and without thrombomodulin in healthy individuals

Author(s):  
Antoine Mairesse ◽  
Jean‐Louis Bayart ◽  
Sandrine Desmet ◽  
Helder Lopes Dos Santos ◽  
Pascale Saussoy ◽  
...  
2017 ◽  
Vol 63 (9) ◽  
pp. 1527-1536 ◽  
Author(s):  
Anna Carobene ◽  
Irene Marino ◽  
Abdurrahman Coşkun ◽  
Mustafa Serteser ◽  
Ibrahim Unsal ◽  
...  

Abstract BACKGROUND The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) European Biological Variation Study (EuBIVAS) has been established to deliver rigorously determined biological variation (BV) indices. EuBIVAS determined BV for serum creatinine using the enzymatic and alkaline picrate measurement methods. METHOD In total, 91 healthy individuals (38 males, 53 females; age range, 21–69 years) were bled for 10 consecutive weeks at 6 European laboratories. An equivalent protocol was followed at each center. Sera were stored at −80 °C before analysis. Analyses for each patient were performed in duplicate within a single run on an ADVIA 2400 system (San Raffaele Hospital, Milan). The data were subjected to outlier and homogeneity analysis before performing CV-ANOVA to determine BV and analytical variation (CVA) estimates with confidence intervals (CI). RESULTS The within-subject BV estimates [CVI (95% CI)] were similar for enzymatic [4.4% (4.2–4.7)] and alkaline picrate [4.7% (4.4–4.9)] methods and lower than the estimate presently available online (CVI = 5.9%). No significant male/female BV differences were found. Significant differences were observed in mean creatinine values between men and women and between Turkish individuals and those of other nationalities. Between-subject BV (CVG) estimates, stratified accordingly, produced CVG values similar to historical BV data. CVA was 1.1% for the enzymatic and 4.4% for alkaline picrate methods, indicating that alkaline picrate methods fail to fulfill analytical performance specifications for imprecision (CVAPS). CONCLUSIONS The serum creatinine CVI obtained by EuBIVAS specifies a more stringent CVAPS than previously identified. The alkaline picrate method failed to meet this CVAPS, raising questions regarding its future use.


Author(s):  
Fatma Ucar ◽  
Gonul Erden ◽  
Seyda Ozdemir ◽  
Nurgul Ozcan ◽  
Erdem Bulut ◽  
...  

AbstractBackground:Most of the factors causing preanalytical and analytical variation in ammonia measurement have been identified. Biological variation data for ammonia is still lacking. We therefore estimated the components of biological variation (within-subject=CVMethods:Blood samples from 20 healthy subjects were collected in K2EDTA tubes daily over a period of 4 consecutive days from each subject. Each plasma sample was split into two aliquots; one was immediately analyzed as the samples were collected and the other was stored –80 °C until testing at the end of the collection period and analyzed at once in one analytical run. All samples were analyzed in duplicate. Estimations were calculated according to Fraser and Harris methods.Results:CVConclusions:The present study for the first time described the components of biological variation for ammonia in healthy individuals. These data regarding biological variation of ammonia could be useful for a better evaluation of ammonia test results in clinical interpretation and for determining quality specifications based on biological variation.


1997 ◽  
Vol 78 (04) ◽  
pp. 1215-1220 ◽  
Author(s):  
D Prasa ◽  
L Svendsen ◽  
J Stürzebecher

SummaryA series of inhibitors of factor Xa (FXa) were investigated using the thrombin generation assay to evaluate the potency and specificity needed to efficiently block thrombin generation in activated human plasma. By inhibiting FXa the generation of thrombin in plasma is delayed and decreased. Inhibitor concentrations which cause 50 percent inhibition of thrombin generation (IC50) correlate in principle with the Ki values for inhibition of free FXa. Recombinant tick anticoagulant peptide (r-TAP) is able to inhibit thrombin generation with considerably low IC50 values of 49 nM and 37 nM for extrinsic and intrinsic activation, respectively. However, the potent synthetic, low molecular weight inhibitors of FXa (Ki values of about 20 nM) are less effective in inhibiting the generation of thrombin with IC50 values at micromolar concentrations.The overall effect of inhibitors of FXa in the thrombin generation assay was compared to that of thrombin inhibitors. On the basis of similar Ki values for the inhibition of the respective enzyme, synthetic FXa inhibitors are less effective than thrombin inhibitors. In contrast, the highly potent FXa inhibitor r-TAP causes a stronger reduction of the thrombin activity in plasma than the most potent thrombin inhibitor hirudin.


Author(s):  
Carmen Ricós ◽  
Pilar Fernández-Calle ◽  
Elisabet Gonzalez-Lao ◽  
Margarida Simón ◽  
Jorge Díaz-Garzón ◽  
...  

AbstractObjectivesNumerous biological variation (BV) studies have been performed over the years, but the quality of these studies vary. The objectives of this study were to perform a systematic review and critical appraisal of BV studies on glycosylated albumin and to deliver updated BV estimates for glucose and HbA1c, including recently published high-quality studies such as the European Biological Variation study (EuBIVAS).MethodsSystematic literature searches were performed to identify BV studies. Nine publications not included in a previous review were identified; four for glycosylated albumin, three for glucose, and three for HbA1c. Relevant studies were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Global BV estimates were derived by meta-analysis of BIVAC-compliant studies in healthy subjects with similar study design.ResultsOne study received BIVAC grade A, 2B, and 6C. In most cases, the C-grade was associated with deficiencies in statistical analysis. BV estimates for glycosylated albumin were: CVI=1.4% (1.2–2.1) and CVG=5.7% (4.7–10.6), whereas estimates for HbA1c, CVI=1.2% (0.3–2.5), CVG=5.4% (3.3–7.3), and glucose, CVI=5.0% (4.1–12.0), CVG=8.1% (2.7–10.8) did not differ from previously published global estimates.ConclusionsThe critical appraisal and rating of BV studies according to their methodological quality, followed by a meta-analysis, generate robust, and reliable BV estimates. This study delivers updated and evidence-based BV estimates for glycosylated albumin, glucose and HbA1c.


Author(s):  
Michela Bottani ◽  
Aasne K. Aarsand ◽  
Giuseppe Banfi ◽  
Massimo Locatelli ◽  
Abdurrahman Coşkun ◽  
...  

Abstract Objectives Thyroid biomarkers are fundamental for the diagnosis of thyroid disorders and for the monitoring and treatment of patients with these diseases. The knowledge of biological variation (BV) is important to define analytical performance specifications (APS) and reference change values (RCV). The aim of this study was to deliver BV estimates for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), thyroglobulin (TG), and calcitonin (CT). Methods Analyses were performed on serum samples obtained from the European Biological Variation Study population (91 healthy individuals from six European laboratories; 21–69 years) on the Roche Cobas e801 at the San Raffaele Hospital (Milan, Italy). All samples from each individual were evaluated in duplicate within a single run. The BV estimates with 95% CIs were obtained by CV-ANOVA, after analysis of variance homogeneity and outliers. Results The within-subject (CV I ) BV estimates were for TSH 17.7%, FT3 5.0%, FT4 4.8%, TG 10.3, and CT 13.0%, all significantly lower than those reported in the literature. No significant differences were observed for BV estimates between men and women. Conclusions The availability of updated, in the case of CT not previously published, BV estimates for thyroid markers based on the large scale EuBIVAS study allows for refined APS and associated RCV applicable in the diagnosis and management of thyroid and related diseases.


2012 ◽  
Vol 58 (12) ◽  
pp. 1703-1710 ◽  
Author(s):  
Yeo-Min Yun ◽  
Julianne Cook Botelho ◽  
Donald W Chandler ◽  
Alex Katayev ◽  
William L Roberts ◽  
...  

BACKGROUND Testosterone measurements that are accurate, reliable, and comparable across methodologies are crucial to improving public health. Current US Food and Drug Administration–cleared testosterone assays have important limitations. We sought to develop assay performance requirements on the basis of biological variation that allow physiologic changes to be distinguished from assay analytical errors. METHODS From literature review, the technical advisory subcommittee of the Partnership for the Accurate Testing of Hormones compiled a database of articles regarding analytical and biological variability of testosterone. These data, mostly from direct immunoassay-based methodologies, were used to specify analytical performance goals derived from within- and between-person variability of testosterone. RESULTS The allowable limits of desirable imprecision and bias on the basis of currently available biological variation data were 5.3% and 6.4%, respectively. The total error goal was 16.7%. From recent College of American Pathologists proficiency survey data, most currently available testosterone assays missed these analytical performance goals by wide margins. Data from the recently established CDC Hormone Standardization program showed that although the overall mean bias of selected certified assays was within 6.4%, individual sample measurements could show large variability in terms of precision, bias, and total error. CONCLUSIONS Because accurate measurement of testosterone across a wide range of concentrations [approximately 2–2000 ng/dL (0.069–69.4 nmol/L)] is important, we recommend using available data on biological variation to calculate performance criteria across the full range of expected values. Additional studies should be conducted to obtain biological variation data on testosterone from women and children, and revisions should be made to the analytical goals for these patient populations.


2012 ◽  
Vol 130 ◽  
pp. S127
Author(s):  
Olga Smirnova ◽  
Yuriy Namestnikov ◽  
Gelena Berezovskaya ◽  
Elena Klokova ◽  
Mikhail Karpenko ◽  
...  

Author(s):  
Shuo Wang ◽  
Min Zhao ◽  
Zihan Su ◽  
Runqing Mu

Abstract Objectives A large number of people undergo annual health checkup but accurate laboratory criterion for evaluating their health status is limited. The present study determined annual biological variation (BV) and derived parameters of common laboratory analytes in order to accurately evaluate the test results of the annual healthcare population. Methods A total of 43 healthy individuals who had regular healthcare once a year for six consecutive years, were enrolled using physical, electrocardiogram, ultrasonography and laboratory. The annual BV data and derived parameters, such as reference change value (RCV) and index of individuality (II) were calculated and compared with weekly data. We used annual BV and homeostatic set point to calculate personalized reference intervals (RIper) which were compared with population-based reference intervals (RIpop). Results We have established the annual within-subject BV (CVI), RCV, II, RIper of 24 commonly used clinical chemistry and hematology analytes for healthy individuals. Among the 18 comparable measurands, CVI estimates of annual data for 11 measurands were significantly higher than the weekly data. Approximately 50% measurands of II were <0.6, the utility of their RIpop were limited. The distribution range of RIper for most measurands only copied small part of RIpop with reference range index for 8 measurands <0.5. Conclusions Compared with weekly BV, for annual healthcare individuals, annual BV and related parameters can provide more accurate evaluation of laboratory results. RIper based on long-term BV data is very valuable for “personalized” diagnosis on annual health assessments.


Haemophilia ◽  
2018 ◽  
Vol 24 (6) ◽  
pp. e410-e416 ◽  
Author(s):  
Guy Aaron Young ◽  
Roxana Carmona ◽  
Viridiana Cano Garcia