Surface structures and sense organs of the cypris larva of Balanus balanoides as seen by scanning and transmission electron microscopy.

2009 ◽  
Vol 178 (2) ◽  
pp. 161-172 ◽  
Author(s):  
G. Walker ◽  
V. E. Lee
2019 ◽  
Vol 25 (1) ◽  
pp. 250-256
Author(s):  
Zong-You Huang ◽  
Si-Yan Li ◽  
Wen Lu ◽  
Xia-Lin Zheng

AbstractLittle is known of the olfactory mechanisms of host detection in the ovipositors of endoparasitoids and ectoparasitoids. An endoparasitoid Aprostocetus causalis La Salle & Wu (Hymenoptera: Eulophidae) and an ectoparasitoid Quadrastichus mendeli Kim & La Salle (Hymenoptera: Eulophidae: Tetrastichinae) are the two parasitoids of the eucalyptus gall wasp Leptocybe spp. Structures and sense organs of ovipositors of A. causalis and Q. mendeli were studied using scanning and transmission electron microscopy, which provided essential information for exploring the mechanism of host detection by endoparasitoid and ectoparasitoid. The ovipositors of two parasitoids consisted of the first and second valvulae and ended in a pointed tip. There were three types of microtrichia, two types of sensilla chaetica, and one type of sensilla campaniformia on the ovipositors of A. causalis and Q. mendeli. However, Q. mendeli has the fourth type of microtrichia on the ovipositor. The morphology, types, distribution, length, and width of these sensilla and microtrichia were described, and their possible functions are discussed in conjunction with the stinging, oviposition, and the host selection process.


2006 ◽  
Vol 72 (8) ◽  
pp. 5211-5217 ◽  
Author(s):  
David R. Elliott ◽  
Michael Wilson ◽  
Catherine M. F. Buckley ◽  
David A. Spratt

ABSTRACT Interbacterial adhesion of bacteria isolated from canine dental plaque was assessed by performing a visual coaggregation assay. Using conditions mimicking those likely to be encountered in vivo, the entire cultivable plaque microbiota from a single dog was assessed, and eight (6.7%) unique coaggregation interactions were detected for 120 crosses. Transmission electron microscopy was used to visualize several of the bacteria in isolation and as coaggregates, which revealed surface structures that may be involved in adhesion and coaggregation. The results of this study indicate that the prevalence of coaggregating pairs of dental plaque bacteria in dogs is similar to the prevalence of coaggregating pairs of dental plaque bacteria reported in humans. In addition, genera found in both hosts generally exhibited similar coaggregation reactions; however, autoaggregation was found to be more common among oral bacteria isolated from dogs.


1990 ◽  
Vol 64 (3) ◽  
pp. 181-192 ◽  
Author(s):  
A. H. H. Awad ◽  
A. J. Probert

ABSTRACTTransmission electron microscopy shows that the uterus of female Schistosoma margrebowiei possesses the same ultrastructure as that of the tegument but lacks spines and sense organs. It does not possess secretory cells and opens at the gonopore which by scanning electron microscopy was seen to be composed of numerous leaf-like protrusions. The morphology of the ovary is comparable with that of other Digenea. Immature and mature ova possess cortically arranged granules and occur within the posterior zone of the ovary. Cilia and lamellae line the luminal surface of the oviduct and ootype, the lamellae running unidirectionally along the duct. Only a single type of secretory cell is seen within Mehlis' gland and this produces dense bodies which are associated with Goldi bodies. Narrow cytoplasmic channels supported by microtubules deliver these secretory bodies to the ootype. The vitelline duct is lined with cilia and lamellae and the vitelline gland contains four types of cells, S1, S2, S3 and S4. Calcareous corpuscles are found within mature S4 cells.


Author(s):  
G. G. Shaw

The morphology and composition of the fiber-matrix interface can best be studied by transmission electron microscopy and electron diffraction. For some composites satisfactory samples can be prepared by electropolishing. For others such as aluminum alloy-boron composites ion erosion is necessary.When one wishes to examine a specimen with the electron beam perpendicular to the fiber, preparation is as follows: A 1/8 in. disk is cut from the sample with a cylindrical tool by spark machining. Thin slices, 5 mils thick, containing one row of fibers, are then, spark-machined from the disk. After spark machining, the slice is carefully polished with diamond paste until the row of fibers is exposed on each side, as shown in Figure 1.In the case where examination is desired with the electron beam parallel to the fiber, preparation is as follows: Experimental composites are usually 50 mils or less in thickness so an auxiliary holder is necessary during ion milling and for easy transfer to the electron microscope. This holder is pure aluminum sheet, 3 mils thick.


Author(s):  
R. W. Anderson ◽  
D. L. Senecal

A problem was presented to observe the packing densities of deposits of sub-micron corrosion product particles. The deposits were 5-100 mils thick and had formed on the inside surfaces of 3/8 inch diameter Zircaloy-2 heat exchanger tubes. The particles were iron oxides deposited from flowing water and consequently were only weakly bonded. Particular care was required during handling to preserve the original formations of the deposits. The specimen preparation method described below allowed direct observation of cross sections of the deposit layers by transmission electron microscopy.The specimens were short sections of the tubes (about 3 inches long) that were carefully cut from the systems. The insides of the tube sections were first coated with a thin layer of a fluid epoxy resin by dipping. This coating served to impregnate the deposit layer as well as to protect the layer if subsequent handling were required.


Author(s):  
S. Fujishiro

The mechanical properties of three titanium alloys (Ti-7Mo-3Al, Ti-7Mo- 3Cu and Ti-7Mo-3Ta) were evaluated as function of: 1) Solutionizing in the beta field and aging, 2) Thermal Mechanical Processing in the beta field and aging, 3) Solutionizing in the alpha + beta field and aging. The samples were isothermally aged in the temperature range 300° to 700*C for 4 to 24 hours, followed by a water quench. Transmission electron microscopy and X-ray method were used to identify the phase formed. All three alloys solutionized at 1050°C (beta field) transformed to martensitic alpha (alpha prime) upon being water quenched. Despite this heavily strained alpha prime, which is characterized by microtwins the tensile strength of the as-quenched alloys is relatively low and the elongation is as high as 30%.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
R.R. Russell

Transmission electron microscopy of metallic/intermetallic composite materials is most challenging since the microscopist typically has great difficulty preparing specimens with uniform electron thin areas in adjacent phases. The application of ion milling for thinning foils from such materials has been quite effective. Although composite specimens prepared by ion milling have yielded much microstructural information, this technique has some inherent drawbacks such as the possible generation of ion damage near sample surfaces.


Sign in / Sign up

Export Citation Format

Share Document