Radiofrequency versus cryoballoon ablation for atrial fibrillation in the setting of left common pulmonary veins

2019 ◽  
Vol 42 (11) ◽  
pp. 1456-1462 ◽  
Author(s):  
Hugo‐Enrique Coutiño ◽  
Erwin Ströker ◽  
Ken Takarada ◽  
Giacomo Mugnai ◽  
Juan‐Pablo Abugattas ◽  
...  
EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
J Michaelsen ◽  
U Parade ◽  
H Bauerle ◽  
K-D Winter ◽  
U Rauschenbach ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. OnBehalf REGIONAL Background Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) has become an established procedure for the treatment of symptomatic paroxysmal and persistent atrial fibrillation (AF). The safety and efficacy of PVI at community hospitals with low to moderate case numbers is unknown. Aim To determine safety and efficacy of PVI using CBA performed at community hospitals with limited annual case numbers. Methods 1004 PVI performed consecutively between 01/2019 and 09/2020 at 20 community hospitals (each <100 PVI using CBA/year) for symptomatic paroxysmal AF (n = 563) or persistentAF (n= 441) were included in this registry. CBA was performed considering local standards. Procedural data, efficacy and complications were determined. Results Mean number of PVI using CBA/year was 59 ± 26. Mean procedure time was 90.1 ± 31.6 min and mean fluoroscopy time was 19.2 ± 11.4 min. Isolation of all pulmonary veins could be achieved in 97.9% of patients, early termination of CBA due to phrenic nerve palsy was the most frequent reason for incomplete isolation. There was no in-hospital death. 2 patients (0.2%) suffered a clinical stroke. Pericardial effusion occurred in 6 patients (0.6%), 2 of them (0.2%) required pericardial drainage. Vascular complications occurred in 24 patients (2.4%), in 2 of these patients (0.2%) vascular surgery was required. In 48 patients (4.8 %) phrenic nerve palsy was noticed which persisted up to hospital discharge in 6 patients (0.6%). Conclusions PVI for paroxysmal or persistent AF using CBA can be performed at community hospitals with high efficacy and low complication rates despite low to moderate annual procedure numbers.


2019 ◽  
Vol 2 (51) ◽  
pp. 4-7
Author(s):  
Agnieszka Wojdyła-Hordyńska ◽  
Jakub Baran ◽  
Paweł Derejko

The first use of cryoablation in the treatment of arrhythmia has already been described over 40 years ago [1]. Since the introduction of cryoballoon in pulmonary veins isolation in atrial fibrillation treatment, the method has started to attract a lot of interest. Over 350,000 procedures around the word were carried out only by 2018 [2]. Recently, there have been several new publications on the results of second-generation cryoballoon ablation [2, 3, 4]. In view of technology changes, and to summarize years of experience in the treatment of atrial fibrillation, the first Cryousers conference was organized, and held in 2018 in Poland. During this meeting a survey was conducted, obtaining data on the practice of atrial fibrillation treatment in 38 Polish electrophysiological centers performing cryoablation of atrial fibrillation using both balloons, Arctic Front Advance, Medtronic Inc., Minneapolis MN, and radiofrequency point by point ablation. Around 3,745 cryoballoon procedures were performed in the surveyed centers during the year preceding the survey. The survey concerned practical issues related to the qualification and preparation of patients for the procedure, its course, and the results of pulmonary veins isolation in Poland.


2017 ◽  
Vol 81 (5) ◽  
pp. 668-674 ◽  
Author(s):  
Ryobun Yasuoka ◽  
Takashi Kurita ◽  
Yasuhito Kotake ◽  
Naotaka Hashiguchi ◽  
Koichiro Motoki ◽  
...  

Heart Rhythm ◽  
2013 ◽  
Vol 10 (2) ◽  
pp. 241-246 ◽  
Author(s):  
Michael Kühne ◽  
Sven Knecht ◽  
David Altmann ◽  
Peter Ammann ◽  
Beat Schaer ◽  
...  

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
M Ribeiro Da Silva ◽  
G Santos Silva ◽  
P Ribeiro Queiros ◽  
R Teixeira ◽  
J Almeida ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Atrial fibrillation (AF) ablation is a well-established procedure for the treatment of AF. The cornerstone of AF ablation is the complete and durable isolation of pulmonary veins (PV) through radiofrequency (RF) or cryoballoon (CB) ablation. However, PVI durability between RF or CB was not yet established, as reablation strategy and outcomes in patients (pt) undergoing a redo ablation. Purpose To compare RF versus CB regarding PVI status, reablation procedure and outcomes in pts undergoing a second procedure. Methods Single-centre retrospective study of consecutive pts who underwent a redo between 2016 and 2020. PVI status was assessed during electrophysiologic study with electroanatomic mapping system. Index procedures included second generation CB, conventional RF before 2018 and CLOSE protocol guided RF ablation after 2018. We assessed time-to-redo, number and location of reconnected PVs, procedural characteristics, acute and long-term outcomes between RF and CB index PVI. Results Seventy-four (55 RF and 19 CB) pts were included, 68,9% were male, most pts had paroxysmal AF (71,6%) and a mean CHA2DS2-VASc score of 1,14 ± 1,0. No statistically significant differences were noticed in clinical and echocardiographic characteristics between pts within RF or CB cohorts. Median time to reablation was significantly longer in the RF cohort (38,6 months ±33,6) compared to CB (17,0 months ±9,5) (p = 0,014). The number of reconnected PV was higher in CB than the RF cohort, although not significant (2,37 ±1,2 vs 1,75 ±1,4;p = 0,080). Right inferior PV was significantly more reconnected in pts within the CB compared to RF group (73,7% vs 45,6%;p = 0,034), without differences in the other PV reconnection rates. Regarding reablation procedure, all pts were submitted to RF-redo. Fluoroscopy time was shorter for CB than RF cohort (7,4 ±2,9 vs 13,3 ±8,4;p = 0,002). There were no significant differences between the type of reablation (PVI only vs PVI plus other lesions or cavotricuspid isthmus ablation), with no difference in overall acute success. After the redo procedure, no differences were observed in recurrence rate in the blanking period and after 91 days from reablation. Nevertheless, time-to-recurrence (>91 days) was longer for RF than CB group (13,4 months ±10,7 vs 4,3 months ±1,5;p = 0,016). There were 2 pts in the RF group that were submitted to a third ablation procedure (p = 0,725). There were no differences between groups in the composite of adverse cardiovascular (CV) outcomes (stroke/transient ischemic attack, emergency room visit for AF, hospitalization for AF or CV death); p = 0,715. Conclusions After the index procedure, reablation occur later in RF than CB cohort.  Although the number of reconnected PV were similar between groups, right inferior PV was significantly more reconnected in pts originally treated with CB. After redo, time-to-recurrence was shorter for CB cohort. Recurrence and composite of adverse CV outcomes were similar.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Shaojie Chen ◽  
Boris Schmidt ◽  
Stefano Bordignon ◽  
Fabrizio Bologna ◽  
K. R. Julian Chun

Abstract Background Cryoballoon ablation is an established procedure for atrial fibrillation (AF). Patients who had previous pulmonary surgery undergoing pulmonary vein isolation (PVI) were seldom reported. Case presentation We describe an AF ablation using the novel short-tip third-generation cryoballoon in a patient with resected pulmonary vein. All pulmonary veins were successfully isolated without complication. The short-tip third-generation cryoballoon shows advantageous profile in PVI for AF patients with previous pulmonary surgery. Conclusions This report indicates that for AF patient who had previous resected PV surgery, the short-tip CB 3 provides an ideal device option for real-time PVI.


Sign in / Sign up

Export Citation Format

Share Document