Identifying Energy Saving Opportunities In A Process Plant Through Preliminary Energy Audit

2003 ◽  
Vol 38 (1) ◽  
Author(s):  
Zainuddin Abdul Manan
Proceedings ◽  
2021 ◽  
Vol 65 (1) ◽  
pp. 19
Author(s):  
Joanna Southernwood ◽  
Grigoris K. Papagiannis ◽  
Erudino Llano Güemes ◽  
Luisa Sileni

Few small and medium-sized enterprises (SMEs) have undertaken an energy audit to date and even fewer have taken action to implement energy-saving measures. Lack of time, knowledge, and finance, coupled with the low priority that SMEs give to energy management, are the most commonly cited barriers to effective energy management in SMEs. Four projects funded by Horizon 2020 (SPEEDIER, SMEmPower Efficiency, E2DRIVER, and Innoveas) have developed innovative capacity-building programmes designed to eliminate these barriers and encourage SMEs to undertake energy audits and implement the recommended energy efficiency measures. This paper presents an overview of the innovations being tested and suggests a series of policy recommendations that could help to drive uptake of energy audits in SMEs.


2018 ◽  
Vol 150 ◽  
pp. 06040
Author(s):  
M. H. Amlus ◽  
Amlus Ibrahim ◽  
Ahmad Zaidi Abdullah ◽  
Nurhafiza Azizan ◽  
Ummi Naeimah Saraeh

Lately Malaysia energy consumption versus generation rapidly shows increasing due to increasing of load. This phenomenon happened following to advanced country development. Lacking on design and without energy management approach the energy consumption and monthly electrical bill will steadily increased and support the increasing of world carbon emission. Therefore the aim of this work is to approach the simplest innovation task-energy audit , which is load-apportioning strategy. This approach using matching the usage of equipment with fully utilized space and reschedules the time of usage. A one week data was collected by logged power meter at main switchboard at selected building using Fluke Power Recorder. From the data collected, current usage of every load can be determine, then load will be arrange into a group with same portion and same time of usage. The result shows clearly the energy consumption for every single day and indicates the highest and lowest peak. From this work the apportioning strategy implemented by rearrange the load following type of room application. After the arrangement, new measurement was taken and a very good result was established. This work also can be further apply for a huge load that can be save a lot of money for owner especially government by energy saving.


2009 ◽  
Vol 13 (1) ◽  
pp. 185-193 ◽  
Author(s):  
Dusan Gordic ◽  
Milun Babic ◽  
Dubravka Jelic ◽  
Davor Koncalovic ◽  
Nebojsa Jovicic ◽  
...  

This paper deals with energy audit procedure implemented on only Serbian car manufacturer 'Zastava Automobili'. Based on the results of energy auditing and performed technological and economical feasibility studies several energy saving measures were proposed. The measures are related to different energy sources: steam, hot water, compressed air, electricity, and water. Such energy efficiency programs reduce energy costs and increase production profitability of the factory.


2019 ◽  
Vol 17 (1) ◽  
pp. 88
Author(s):  
Herman Nawir ◽  
Kusmanurwira Kusmanurwira ◽  
Alif Firdaus

Abstract In the hotel business, the use of energy is very important, especially in the use of electricity, the portion of usage and allocation of funds for its provision is the largest. It can be seen that equipment such as lights, elevators, refrigerators, laundry, heaters, pumps, to the air conditioning system are some of the dominant tools in operations in the hospitality world. The results of the initial energy audit and detailed audit at the Grand Clarion Hotel Makassar showed that the Energy Consumption Intensity (IKE) is still far from the standard, which is 300 kWh / m2 a year. The building uses the largest amount of electricity in the Grand Clarion Hotel Makassar in Building A, which is in the Guest Room area of the air conditioning unit. The results of the initial energy audit of Energy Consumption Intensity (IKE) electricity were 336.84 kWh / m2 year. Whereas based on the results of a detailed energy audit the electricity consumption intensity (IKE) of electricity is 395.51 kWh / m2 a year. Energy Saving Opportunities (PHE) in this energy audit is to evaluate the AC power in each room and recommend the replacement of lamp types. From the results of the IKE calculation after the application of PHE, it is found that the value is still quite high so that efforts to save must still be done. 


2020 ◽  
Vol 11 (5) ◽  
pp. 1251
Author(s):  
Kaparov Nurtaza MARATOVICH ◽  
Zhibek OMARKHANOVA ◽  
Rakhisheva Aida BEKARYSOVNA ◽  
Saulebaevna Saule SAPARBAYEVA ◽  
Zakirova Dilnara IKRAMKHANOVNA ◽  
...  

The relevance of the research topic is that energy-saving is the key element of modern energy development in the country. In Kazakhstan, energy-saving, and improving the energy efficiency of agriculture is currently a priority task that will solve energy, environmental and economic problems. Without a solution to these problems, the country's development will inevitably hold back. The head of state in the field of energy conservation has set a goal to reduce the energy intensity of the gross domestic product by at least 25% by 2020, and annual energy-savings of 3.5% after 2020. Industry in rural areas consumes more than 70 % of all electricity. As part of the comprehensive plan, their energy audit was conducted 50/50 (50 % of the financing is the enterprises' funds, the remaining 50 % is the state budget). As a result of the energy audit, systematic measures were developed to reduce the energy intensity of the industry, including the electric power industry. Large unproductive losses of energy resources are in the private sector, in this connection, since 2019, the energy audit of JSC "Kazakhstan center for modernization and development of housing and communal services (housing and communal services)" is conducted on budget funds in the private sector. Energy conservation is one of the most important and strategic tasks of the country. Rapidly developing production requires additional energy costs. This is confirmed by the annual increase in energy tariffs. In turn, resources are not unlimited, and their irrational consumption will inevitably lead to not only economic but also to an environmental crisis.


2021 ◽  
Vol 8 ◽  
Author(s):  
Catherine Baxevanou ◽  
Dimitrios Fidaros ◽  
Ilias Giannenas ◽  
Eleftherios Bonos ◽  
Ioannis Skoufos

Broiler facilities consume a lot of energy resulting in natural source depletion and greater greenhouse gas emissions. A way to assess the energy performance of a broiler facility is through an energy audit. In the present paper, an energy protocol for an energy audit is presented covering both phases of data collection and data elaboration. The operational rating phase is analytically and extendedly described while a complete mathematical model is proposed for the asset rating phase. The developed energy audit procedure was applied to poultry chambers located in lowland and mountainous areas of Epirus Greece for chambers of various sizes and technology levels. The energy intensity indices varied from 46 to 89 kWh/m2 of chamber area 0.25–0.48 kWh/kg of produced meat or 0.36–1.3 kWh/bird depending on the chamber technology level (insulation, automation, etc.) and the location where the unit was installed. The biggest energy consumer was heating followed by energy consumption for ventilation and cooling. An advanced technology level can improve energy performance by ~ 27%−31%. Proper insulation (4–7 cm) can offer a reduction of thermal energy consumption between 10 and 35%. In adequately insulated chambers, the basic heat losses are due to ventilation. Further energy savings can be achieved with more precise ventilation control. Automation can offer additional electrical energy saving for cooling and ventilation (15–20%). Energy-efficient lights can offer energy saving up to 5%. The use of photovoltaic (PV) technology is suggested mainly in areas where net-metering holds. The use of wind turbines is feasible only when adequate wind potential is available. Solar thermal energy is recommended in combination with a heat pump if the unit's heating and cooling systems use hot/cold water or air. Finally, the local production of biogas with anaerobic fermentation for producing thermal or electrical energy, or cogenerating both, is a choice that should be studied individually for each farm.


Teknomekanik ◽  
2021 ◽  
Vol 4 (1) ◽  
pp. 30-35
Author(s):  
Andre Kurniawan ◽  
Nanang Qosim ◽  
Remon Lapisa ◽  
Zainal Abadi ◽  
Jasman Jasman

Energy consumption of a building is one of the biggest sources of energy use today. Green Building Comitte Indonesia (GBCI) has launched a concept of energy consumption saving in a nationally standard building. Audit Building energy audit is the way to know how actual building energy consumption is and find alternative solution to decrease energy consumption in order to fulfill the energy saving building criteria. Two types of HVAC systems will be run in the EnergyPlus simulation, split AC and central AC. The previous research proved that central AC is better than split AC system for energy saving in the building with 20 floors. The simulation results show that by using a certain energy system, a more efficient energy system will be achieved and can still maintain the comfort of the room at a temperature of 24 °C and relative humidity according to the Green Building Indonesia standard reference.


Sign in / Sign up

Export Citation Format

Share Document