Some Aspects of Wake-Wake Interactions Regarding Turbine Stator Clocking

2000 ◽  
Vol 123 (3) ◽  
pp. 526-533 ◽  
Author(s):  
Maik Tiedemann ◽  
Friedrich Kost

This investigation is aimed at an experimental determination of the unsteady flowfield downstream of a transonic high pressure turbine stage. The single stage measurements, which were part of a joined European project, were conducted in the windtunnel for rotating cascades of the DLR Go¨ttingen. Laser-2-focus (L2F) measurements were carried out in order to determine the Mach number, flow angle, and turbulence distributions. Furthermore, a fast response pitot probe was utilized to determine the total pressure distribution. The measurement position for both systems was 0.5 axial rotor chord downstream of the rotor trailing edge at midspan. While the measurement position remained fixed, the nozzle guide vane (NGV) was “clocked” to 12 positions covering one NGV pitch. The periodic fluctuations of the total pressure downstream of the turbine stage indicate that the NGV wake damps the total pressure fluctuations caused by the rotor wakes. Furthermore, the random fluctuations are significantly lower in the NGV wake affected region. Similar conclusions were drawn from the L2F turbulence data. Since the location of the interaction between NGV wake and rotor wake is determined by the NGV position, the described effects are potential causes for the benefits of “stator clocking” which have been observed by many researchers.

Author(s):  
O¨zhan H. Turgut ◽  
Cengiz Camcı

A computational validation study related to aerodynamic loss generation mechanisms is performed in an axial flow turbine nozzle guide vane (NGV). The 91.66 cm diameter axial flow turbine research facility has a stationary nozzle guide vane assembly and a 29 bladed HP turbine rotor. The NGV inlet and exit Reynolds numbers based on midspan axial chord are around 300000 and 900000, respectively. The effect of grid structure on aerodynamic loss generation is investigated. GAMBIT and TGRID combination is used for unstructured grid, whereas GRIDPRO is the structured grid generator. For both cases, y+ values are kept below unity. The finite-volume flow solver ANSYS CFX with SST k–ω turbulence model is employed. Experimental flow conditions are imposed at the boundaries. The flow transition effect and the influence of corner fillets at the vane-endwall junction are also studied in this paper. Grid independence study is performed with static pressure coefficient distribution at the mid-span of the vane and the total pressure coefficient at the NGV exit. The velocity distributions and the total pressure coefficient at the NGV exit plane are in very good agreement with the experimental data. This validation study shows that the effect of future geometrical modifications on the endwalls and the vane will be predicted reasonably accurately. The current study shows that an accurately measured turbine stage geometry, a properly prepared block structured/body fitted grid, a state of the art transitional flow implementation, and realistic boundary conditions coming from high resolution turbine experiments are all essential ingredients of a successful NGV aerodynamic loss quantification via computations.


2016 ◽  
Vol 138 (5) ◽  
Author(s):  
Özhan H. Turgut ◽  
Cengiz Camci

This paper deals with the computational predictability of aerodynamic losses in a turbine nozzle guide vane (NGV) flow. The paper shows that three-dimensional (3D) computations of Reynolds-Averaged Navier Stokes (RANS) equations have the ability to adequately represent viscous losses in the presence of laminar flows, transitional regions, and fully turbulent flow areas in the NGV of an high pressure (HP) turbine stage. The Axial Flow Turbine Research Facility (AFTRF) used for the present experimental results has an annular NGV assembly and a 29-bladed HP turbine rotor spinning at 1330 rpm. The NGV inlet and exit Reynolds numbers based on midspan axial chord are around 300,000 and 900,000, respectively. A general purpose finite-volume 3D flow solver with a shear stress transport (SST) k–ω turbulence model is employed. The current computational study benefits from these carefully executed aerodynamic experiments in the NGV of the AFTRF. The grid independence study is performed with static pressure coefficient distribution at the midspan of the vane and the total pressure coefficient at the NGV exit. The effect of grid structure on aerodynamic loss generation is emphasized. The flow transition effect and the influence of corner fillets at the vane–endwall junction are also studied. The velocity distributions and the total pressure coefficient at the NGV exit plane are in very good agreement with the experimental data. This validation study shows that the effect of future geometrical modifications on the turbine endwall surfaces will be predicted reasonably accurately. The current study also indicates that an accurately defined turbine stage geometry, a properly prepared block-structured/body-fitted grid, a state-of-the-art transitional flow implementation, inclusion of fillets, and realistic boundary conditions coming from high-resolution turbine experiments are all essential ingredients of a successful turbine NGV aerodynamic loss quantification via computations. This validation study forms the basis for the successful future generation of nonaxisymmetric endwall surface modifications in AFTRF research efforts.


Author(s):  
Tolga Yasa ◽  
Guillermo Paniagua ◽  
Jens Fridh ◽  
Damian Vogt

The understanding of shock interactions and mixing phenomena is crucial to design and analysis of advanced turbines. A nozzle guide vane (NGV) is experimentally investigated at subsonic and transonic off-design conditions (M2is of 0.6 and 0.95) in an annular sector at the Royal Institute of Technology (KTH). The effect of cooling ejection (3% of main stream mass flow rate) on the downstream flow field is also studied. The airfoil loading is monitored with pneumatic taps. The downstream pressure field is characterized at four different axial locations using a 5-hole probe and a total pressure probe that contains a single piezo-resistive transducer. The probe with a piezo resistive transducer is also used as a virtual 3-hole probe to measure the flow angle. The time-averaged yaw angle measured with the virtual 3-hole probe is in agreement with the 5-hole probe data. At subsonic conditions the wake causes a pressure loss of 7% of the upstream total pressure and covers 25% of the pitch whereas the pressure deficit is doubled in transonic operation. The coolant ejection results in an additional loss of 2% of the upstream total pressure. The flow speed does not have a significant effect on the wake width at 7% Cax. However, the low pressure region has different width at far downstream depending on the flow velocity. The fillet at the hub region has a significant effect on the secondary flow development. The frequency spectrums at the different conditions clearly reveal the shear layers. The results aim to help the characterization of mixing phenomena downstream of the NGV.


Author(s):  
Özhan H. Turgut ◽  
Cengiz Camcı

Three different ways are employed in the present paper to reduce the secondary flow related total pressure loss. These are nonaxisymmetric endwall contouring, leading edge (LE) fillet, and the combination of these two approaches. Experimental investigation and computational simulations are applied for the performance assessments. The experiments are carried out in the Axial Flow Turbine Research Facility (AFTRF) having a diameter of 91.66cm. The NGV exit flow structure was examined under the influence of a 29 bladed high pressure turbine rotor assembly operating at 1300 rpm. For the experimental measurement comparison, a reference Flat Insert endwall is installed in the nozzle guide vane (NGV) passage. It has a constant thickness with a cylindrical surface and is manufactured by a stereolithography (SLA) method. Four different LE fillets are designed, and they are attached to both cylindrical Flat Insert and the contoured endwall. Total pressure measurements are taken at rotor inlet plane with Kiel probe. The probe traversing is completed with one vane pitch and from 8% to 38% span. For one of the designs, area averaged loss is reduced by 15.06%. The simulation estimated this reduction as 7.11%. Computational evaluation is performed with the rotating domain and the rim seal flow between the NGV and the rotor blades. The most effective design reduced the mass averaged loss by 1.28% over the whole passage at the NGV exit.


Author(s):  
Julien Clinckemaillie ◽  
Tony Arts

This paper aims at evaluating the characteristics of the wakes periodically shed by the rotating bars of a spoked-wheel type wake generator installed upstream of a high-speed low Reynolds linear low-pressure turbine blade cascade. Due to the very high bar passing frequency obtained with the rotating wake generator (fbar = 2.4−5.6 kHz), a fast-response pressure probe equipped with a single 350 mbar absolute Kulite sensor has been used. In order to measure the inlet flow angle fluctuations, an angular aerodynamic calibration of the probe allowed the use of the virtual three-hole mode; additionally, yielding yaw corrected periodic total pressure, static pressure and Mach number fluctuations. The results are presented for four bar passing frequencies (fbar = 2.4/3.2/4.6/5.6 kHz), each tested at three isentropic inlet Mach numbers M1,is = 0.26/0.34/0.41 and for Reynolds numbers varying between Re1,is = 40,000 and 58,000, thus covering a wide range of engine representative flow coefficients (ϕ = 0.44−1.60). The measured wake characteristics show fairly good agreement with the theory of fixed cylinders in a cross-flow and the evaluated total pressure losses and flow angle variations generated by the rotating bars show fairly good agreement with theoretical results obtained from a control volume analysis.


Author(s):  
I. Kassens ◽  
M. Rautenberg

In a centrifugal compressor adjustable inlet guide vanes (IGV) in front of the impeller are used to regulate the pressure ratio and the mass flow. The stationary measurement of the velocity profile in front of the impeller with different angles of the IGV displays shock losses at the inlet edge of blade of the impeller. In the partial-load region (e.g. partial-load efficiency) the radial distribution of the flow influences considerably the performance of the impeller. The tested compressor consists of an adjustable IGV with straight vanes, a shrouded impeller and a vaneless, parallel diffuser. In the first measurement location, behind the IGV, total pressure, static pressure and flow angle were measured with a 5-hole cylinder probe. In the second measurement location, in front of the impeller, the measurement of the total pressure was carried out with a Kiel probe and the flow angle with a Cobra probe accordingly the static wall pressure was measured. Taking into consideration the fundamental thermodynamical equations it was possible to determine the velocity profiles because of the measured distributions of the flow angle in these two measurement locations. For different angles of the IGV and with various mass flows the distributions of the deflection defect behind the IGV are described. Starting with the measured distributions of the flow in front of the impeller the flow angles at the impeller inlet are calculated and the distributions of the incidence angle at the impeller inlet are figured out.


Author(s):  
O¨zhan H. Turgut ◽  
Cengiz Camcı

Nonaxisymmetric endwall contouring has recently become one of the ways to minimize the secondary flow related losses in a turbine nozzle guide vane (NGV) passage. In this study, a specific nonaxisymmetric endwall contouring design methodology is introduced. Fourier series based splines at different axial locations are generated and combined with the help of stream-wise B-splines within solid modeling program. Eight different contoured endwalls are presented in this paper. Computational study of these designs are performed by the finite-volume flow solver. The SST k–ω turbulence model is selected and a body-fitted structured grid is used. Total pressure distribution at the NGV exit shows that contouring the endwall effectively changes the results. Among from these various designs, the most promising one is with the contouring extended in the upstream of the vane leading edge. Mass-averaged value of 3.2% total pressure loss reduction is achieved at the NGV exit plane. The current study was performed in a rotating turbine rig simulating a state of the art HP turbine stage. An NGV only simulation is performed. This approach is helpful in isolating rotor-stator influence and the possible upstream flow modifications of the rim seal cavity flow existing in the rotating turbine research rig. The investigation including the rotor-stator interaction and rim seal cavity flow is the topic of a subsequent paper currently under progress.


Author(s):  
L. He ◽  
V. Menshikova ◽  
B. R. Haller

A computational study is carried out on the influence of turbine inlet temperature distortion (hot streak). The hot streak effects are examined from both aeromechanical (forced blade vibration) and aero-thermal (heat transfer) points of view. Computations are firstly carried out for a transonic HP turbine stage, and the steady and unsteady surface pressure results are compared with the corresponding experimental data. Subsequent analysis is carried out for hot-streaks with variable circumferential wavelength, corresponding to different numbers of combustion burners. The results show that the circumferential wavelength of the temperature distortion can significantly change unsteady forcing as well as the heat-transfer to rotor blades. In particular, when the hot-streak wavelength is the same as the nozzle guide vane (NGV) blade pitch, there is a strong dependence of the preferential heating characteristics on the relative clocking position between hot-streak and NGV blade. However, this clocking dependence is shown to be qualitatively weakened for the cases with fewer hot streaks with longer circumferential wavelengths.


2017 ◽  
Vol 139 (11) ◽  
Author(s):  
Ioanna Aslanidou ◽  
Budimir Rosic

This paper presents an experimental investigation of the concept of using the combustor transition duct wall to shield the nozzle guide vane leading edge. The new vane is tested in a high-speed experimental facility, demonstrating the improved aerodynamic and thermal performance of the shielded vane. The new design is shown to have a lower average total pressure loss than the original vane, and the heat transfer on the vane surface is overall reduced. The peak heat transfer on the vane leading edge–endwall junction is moved further upstream, to a region that can be effectively cooled as shown in previously published numerical studies. Experimental results under engine-representative inlet conditions showed that the better performance of the shielded vane is maintained under a variety of inlet conditions.


2003 ◽  
Vol 125 (3) ◽  
pp. 513-520 ◽  
Author(s):  
Kam S. Chana ◽  
Terry V. Jones

Detailed experimental investigations have been performed to measure the heat transfer and static pressure distributions on the rotor tip and rotor casing of a gas turbine stage with a shroudless rotor blade. The turbine stage was a modern high pressure Rolls-Royce aero-engine design with stage pressure ratio of 3.2 and nozzle guide vane (ngv) Reynolds number of 2.54E6. Measurements have been taken with and without inlet temperature distortion to the stage. The measurements were taken in the QinetiQ Isentropic Light Piston Facility and aerodynamic and heat transfer measurements are presented from the rotor tip and casing region. A simple two-dimensional model is presented to estimate the heat transfer rate to the rotor tip and casing region as a function of Reynolds number along the gap.


Sign in / Sign up

Export Citation Format

Share Document